Schneider Electric TSXETG100 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Schneider Electric TSXETG100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Schneider Electric TSXETG100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Schneider Electric TSXETG100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Schneider Electric TSXETG100 should contain:
- informations concerning technical data of Schneider Electric TSXETG100
- name of the manufacturer and a year of construction of the Schneider Electric TSXETG100 item
- rules of operation, control and maintenance of the Schneider Electric TSXETG100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Schneider Electric TSXETG100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Schneider Electric TSXETG100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Schneider Electric service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Schneider Electric TSXETG100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Schneider Electric TSXETG100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 Instruction Bulletin 63230-319-211A1 2/2006 ConneXium Ethernet Gate wa y TSXETG100 User’ s Guide Instrucciones en Español: página 19 Instructions en Français: page 39 Anweisungen auf Deutsch : Seite 59 Retain for future use. ENGLISH TABLE OF CONTENTS INTRODUCTION .......... ........................................................ ...........[...]

  • Page 2

    ConneXium ™ Ethernet Gateway 63230-319-211A1 Introduction 2/2006 © 2006 Schneider Electric. All Rights R eserved. 2 ENGLISH INTRODUCTION This manual is to be used with a ConneXium ™ ETG100 with firmwa re version 2.0 or higher. For insta llation information, see the installati on guide. The ETG100 is a communications dev i ce that provides conn[...]

  • Page 3

    63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Accessing the ETG Over a Network © 2006 Schneider Electric. All Rights Reserved. 3 ENGLISH Additional Resources Documentation and Firmware: Go to www.telemecanique.com, select Products > Products index > Systems and architectures > Connexium. ACCESSING THE ETG OVER A NETWORK After you [...]

  • Page 4

    ConneXium ™ Ethernet Gateway 63230-319-211A1 ETG User Interface OVERVIEW 2/2006 © 2006 Schneider Electric. All Rights R eserved. 4 ENGLISH ETG USER INTERFACE OVERVIEW The ETG ships with seven pre-installed we b pages used for ETG setup and configuration. See Table 1 for a description of each web page. Table 1: ETG static web pages ETG Web P age [...]

  • Page 5

    63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 5 ENGLISH SETUP To access the Setup web page links, click Setup on the ET G menu b ar . Ethernet and TCP/IP Settings NOTE: After making changes to the Ethernet parameters and clicking Apply, the ETG will reboot. Action Result 1. From the Set[...]

  • Page 6

    ConneXium ™ Ethernet Gateway 63230-319-211A1 Setup 2/2006 © 2006 Schneider Electric. All Rights R eserved. 6 ENGLISH Duplicate IP Ad dress Detection While connected to your network, the ETG publishes its IP address. To avoid any duplicate IP address conf licts, the ETG uses the Address Resolution Protocol (ARP) to see if any other device on your[...]

  • Page 7

    63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 7 ENGLISH Serial Po rt Action Result 1. From the Setup page, click Serial Port . O pens the Serial Port page. 2. Select your mode, physical interface, transmission mode, baud rate, par ity, and response timeout (see Table 4 on page 7). Selec[...]

  • Page 8

    ConneXium ™ Ethernet Gateway 63230-319-211A1 Setup 2/2006 © 2006 Schneider Electric. All Rights R eserved. 8 ENGLISH Device List Before you begin, keep in mind the followi ng: For master mode usage of the COM port: • Modbus devices do not have to be defin ed in the De vice List, but it helps you manage your system. Master Mode Device List Setu[...]

  • Page 9

    63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 9 ENGLISH Slave Mode Device List Setup Serial port slave mode allo ws serial Modbus master device s to access information from serial slave devices across a TCP/IP network. Fig ure 6 below illustrates how the devices are co nnected using the[...]

  • Page 10

    ConneXium ™ Ethernet Gateway 63230-319-211A1 Setup 2/2006 © 2006 Schneider Electric. All Rights R eserved. 10 ENGLISH User Accounts ETG users are assigned user names and p asswords. Each user belongs to a group, and each group has access rights to the ETG Web pages assigned by the ETG administrator. NOTE: There are two default user accounts: Adm[...]

  • Page 11

    63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 11 ENGLISH Web Page Access Action Result 1. From the Setup page, click Web Pa ge Access . Opens the Web Page Access page. 2. In th e Ethernet & TCP/IP row, s elect the access level (None, Read-only, or Full) t hat each user group will ha[...]

  • Page 12

    ConneXium ™ Ethernet Gateway 63230-319-211A1 Setup 2/2006 © 2006 Schneider Electric. All Rights R eserved. 12 ENGLISH Modbus TCP/IP Filtering This function allows the administrator to sp ecify Modbus TCP/IP client devices that have or do not have access to serial slave devi ces connected to the ETG. NOTE: The re is an anonymous Modbus TC P/IP ad[...]

  • Page 13

    63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 13 ENGLISH SNMP Parameter s The ETG supports SNMP, allowing a network administrator to remotely access an ETG with an SNMP manager an d view the networking status and diagnostics in the MIB2 format. Action Result 1. From the Setup page, clic[...]

  • Page 14

    ConneXium ™ Ethernet Gateway 63230-319-211A1 Diagnostics 2/2006 © 2006 Schneider Electric. All Rights R eserved. 14 ENGLISH DIAGNOSTICS To access the Diagnostics web page links, click Diagnostics on the ETG menu bar . Statistics NOTE: This page will show accumulate d readings since the ETG was last activated. If power to the ETG is lost , all cu[...]

  • Page 15

    63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Diagnostics © 2006 Schneider Electric. All Rights Reserved. 15 ENGLISH Interpreting Statistics Statistic Description Ethernet Link Status A status string that represents the speed and duplex setting being used to commun icate with the linking partner. Frames Transmitted OK A counter that increm[...]

  • Page 16

    ConneXium ™ Ethernet Gateway 63230-319-211A1 Diagnostics 2/2006 © 2006 Schneider Electric. All Rights R eserved. 16 ENGLISH Serial Port Frames Sent A counter that increments e ach time a frame is sent. Frames Received A counter that increments each time a f rame is received. CRC Errors A counter that increm ents each time a message is receive d [...]

  • Page 17

    63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Diagnostics © 2006 Schneider Electric. All Rights Reserved. 17 ENGLISH Read Device Registers Action Result 1. From the Diagnostics page, click Read Device Registers . Opens t he Read Device Regi sters page. 2. Enter the device ID, startin g register number, and th e number of regi sters to read[...]

  • Page 18

    ConneXium ™ Ethernet Gateway 63230-319-211A1 Instruction Bulletin 2/2006 ENGLISH Electrical equipment should be installed, opera ted, serv iced, and maintained only by qualified electrical personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. www .schneider-electric.com www .te[...]

  • Page 19

    ConneXium ™ Ethernet Gateway 63230-319-211A1 Handbuch 2/2006 DEUTSC H Elektrisches Gerät sollte st ets von qualifizierten Elektr ikern installiert, betrieben und gewartet werden. Schneider Electric übern immt keine Verantwortung für jegliche Konsequenzen, die sich aus der Verw endung dieses Gerãts ergeben könnten. www .schneider-electric.com[...]