Schneider Electric 750VA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Schneider Electric 750VA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Schneider Electric 750VA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Schneider Electric 750VA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Schneider Electric 750VA should contain:
- informations concerning technical data of Schneider Electric 750VA
- name of the manufacturer and a year of construction of the Schneider Electric 750VA item
- rules of operation, control and maintenance of the Schneider Electric 750VA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Schneider Electric 750VA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Schneider Electric 750VA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Schneider Electric service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Schneider Electric 750VA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Schneider Electric 750VA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Operation Manual Smart-UPS ® X-Series UPS 750 V A 1000 V A 1500 V A 120V 230V[...]

  • Page 2

    Smart-UPS X-Series Ope ration i Overview ......... ...... ...... ...... .......... ...... ...... ...... .......... ...... .... 1 About the UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product[...]

  • Page 3

    Smart-UPS X-Series Ope ration ii Emergency Power Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 EPO Over view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Normally ope n contac ts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Normally clo sed con tact[...]

  • Page 4

    1 Smart-UPS X-Series Operation Overview About the UPS The APC ® by Schn eide r Elec tric S mart -U PS ® X-Series i s a high pe rformance Uninter ruptibl e Power Supply (UPS) . It prov ides prot ectio n for ele ctronic e quipment f rom utili ty power bl ackouts , brownouts, sags, and su r ges; smal l uti lity f luctu ations and lar ge disturban ce[...]

  • Page 5

    Smart-UPS X-Series Ope ration 2 Specifications Operating Con ditions This u nit is in tended for indoor use only . Select a l ocation s turdy enoug h to support the weight of the uni t and Exter nal Batte ry Packs ( XLBP). Do not oper ate the UPS where t here is e xcessi ve dust, or the t emperatur e or humidit y are out side t he spec ified limit [...]

  • Page 6

    3 Smart-UPS X-Series Operation Operation Connect Eq uipment to t he UPS Note: The UPS will c har ge to 90% c apacity i n the fir st thre e hours of normal op eration. Do not expec t full battery run capabili ty duri ng this ini tial cha rge period. 1. Connect e quipme nt t o the outl ets o n the rear panel of the UPS. Do not use extension cord s, p[...]

  • Page 7

    Smart-UPS X-Series Ope ration 4 Display Interface Overview Using the display interface Use U P and D OWN to scroll thr ough the main menu opt ions. Pres s E NTER to view the sub-menus u nder each main menu opti on. Pres s E SCAPE to exi t a su b-menu and re turn to a main menu. Stan d a rd Me n us The S tandard menus are the most commonly used menu[...]

  • Page 8

    5 Smart-UPS X-Series Operation Advanced Men us The Advance d menus pr ovide addi tional op tions for the UPS and are ava ilable o nly if the displ ay interf ace is co nfigured to use the Advan ced Menus. About Disp lay information about this unit: • Unit model n umb er • Serial num ber • Battery installatio n date • Suggested battery replac[...]

  • Page 9

    Smart-UPS X-Series Ope ration 6 Configuration UPS Settings St art-up Settings Configur e thes e settin gs at i nitial start- up, usin g the disp lay interface or APC PowerChute ® software . Note: During s t art-up, use the display interfa ce to c onfigure these s ettings . If nothi ng is select ed, the until wil l use the default sett ings. Genera[...]

  • Page 10

    7 Smart-UPS X-Series Operation Controllable Outlet Group s Overview The rear panel of the UPS has multiple outle ts, some ar e grouped i nto Cont rollabl e Outlet Groups , all others are th e UPS outlet s. All of t hese group s can be configur ed to tur n off , turn on, shut down, and reboot c onnected e quipment, independe ntly of e ach oth er . T[...]

  • Page 11

    Smart-UPS X-Series Ope ration 8 Model-spec ific Controllable Ou tlet Grou p s 750V A, 120 V and 230 V . 1000 V A, 120 V and 230 V . 1500 V A, 120 V and 230 V .  Controllable Outlet Group (s)  UPS outlets su 0436 a su043 8a su 0435 a su04 37a su 0488 a su048 7a[...]

  • Page 12

    9 Smart-UPS X-Series Operation Using the Contr ollable Outlet Group s and UPS outlet s The UPS outl ets funct ion as a master s witch. They t urn on fi rst when power is appl ied, sh ut of f last when ther e is a power outage and battery run-time h as been exhausted . The UPS outl ets must be turned on for th e Contr ollable Ou tlet Grou ps to turn[...]

  • Page 13

    Smart-UPS X-Series Ope ration 10 Network Man age ment Card Settin gs These set ting s are avai lable onl y on units that have a Ne twork Managemen t Card (N MC) and ar e set in the fact or y . These se tt ing s can only be modified us ing an ext er nal interface, like th e NMC web i nt erf ac e. • N M C I P A d d r e s s M o d e • N M C I P A d[...]

  • Page 14

    11 Smart-UPS X-Series Operation Emergenc y Powe r Off EPO Overview The Emer gency Power Of f (EPO) option is a safet y feature that will immedia tely disconnect all connecte d equip ment from ut ility po w er . The UPS will immedia tely shut down and will not s witch t o batter y power . The UPS must be manually r e-start ed to re- apply power to c[...]

  • Page 15

    Smart-UPS X-Series Ope ration 12 T roubleshooting Prob lem and Possible Cause Solution The UPS will n ot turn on or there is no output The unit ha s not been tur ned on. Press the ON button once to turn on the UPS. The UPS is not connected to utility powe r . Ensure that the power cable is securely connected to the unit and to the utility power su [...]

  • Page 16

    13 Smart-UPS X-Series Operation All indi cators ar e illuminate d and the UPS is plugged into a wall o utlet The UP S has sh ut dow n and th e batte ry has disch arged fr om an extended outage. None. The UPS will retu rn to normal op eration when the po wer is restored and the battery has a suf ficient charg e. The r eplace bat tery LED is i llumin[...]

  • Page 17

    Smart-UPS X-Series Ope ration 14 Service and Support Service If the UPS req uire s serv ice, d o not re turn it to the de aler . Foll ow thes e step s : 1. Review the p roble ms discusse d in T r oubleshooting in this m an ual to e limin a te com m on problems. 2. If the pr oblem pe rsists, contact APC Custome r Support throug h the APC W eb si te,[...]

  • Page 18

    15 Smart-UPS X-Series Operation Smart-UPS Factory W arranty LIMITED W ARRANTY American Power Conversion (APC) warrants its Smart-UPS (Products) to be fr ee from defects in materials a nd workma nship for a period of th ree (3) years, excluding the batteries, whic h are warranted for two (2) y ears from date of purchase. APC's obligatio n u nd [...]

  • Page 19

    Harmonized S tandards EN6095 0-1; IEC 60950-1; EN62040 -1-1; EN55 022; EN55024; IEC6100 0-3-2, 3-3, 4- 2, 4-3, 4-4 , 4-5, 4-6, 4-1 1 Appl icab le Counc il Dir ect iv es 2006 /95/EC ; 2004/10 8/EC T ype of Equipment Uninterruptible Power Supply Mode l Numb ers SMX750I, SMX1000I, SMX150 0RMI2U, SM X1500RMI2U NC Manufactur ers American Power Conversio[...]

  • Page 20

    06/2009 990-3458-001 © 2009 APC by Schnei der Electri c. APC, t he APC lo go are owne d by Schn eider El ectric Indu stries S.A.S., American Power Conversi on Corporation, or their affilia ted companies. All other trademarks are property of their respective owners.[...]