RuggedCom M2100 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of RuggedCom M2100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of RuggedCom M2100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of RuggedCom M2100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of RuggedCom M2100 should contain:
- informations concerning technical data of RuggedCom M2100
- name of the manufacturer and a year of construction of the RuggedCom M2100 item
- rules of operation, control and maintenance of the RuggedCom M2100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of RuggedCom M2100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of RuggedCom M2100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the RuggedCom service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of RuggedCom M2100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the RuggedCom M2100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    RuggedCom Inc. I 30 Whitmore Road, Woodbridge, Ontario, Canada L4L 7Z4 Tel : 905-856-5288 I Fax : 905-856-199 5 I Toll Free: 1-888-264-0006 RuggedSwitch ™ M2100 MIL-STD 19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports Installation Guide www.RuggedCom.com[...]

  • Page 2

    2 © 2008 RuggedCom Inc. All rights re served Rev106 Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limit s are designed to provide reasonable protection against harmful interference w[...]

  • Page 3

    3 © 2008 RuggedCom Inc. All rights re served Rev106 T able of Content s 1 Table of Figur es ............................................................................................................... ....... 4 2 Table of Tables ................................................................................................................ ....[...]

  • Page 4

    4 © 2008 RuggedCom Inc. All rights re served Rev106 1 T able of Figures Figure 1: Ethernet panel LED de scription...................................................................................... .. 7 Figure 2: 10FL ST connector................................................................................................... ........ 8 Figure[...]

  • Page 5

    5 © 2008 RuggedCom Inc. All rights re served Rev106 3 Product Overview 3.1 Functional Overview & Feature Highlights The RuggedSwitch™ M2100 is an MIL-STD hardened, fully managed, modular, Ethernet switch specifically designed to operate reliably in harsh environments. The M2100's superior ruggedized hardware design coupled with the embe[...]

  • Page 6

    6 © 2008 RuggedCom Inc. All rights re served Rev106 • MIL-STD 167 – Vibration • MIL-STD 461 – EMI • MIL-STD 1399 – Magnetic Fiel d (DC Magnetic Exposure) • MIL-STD 810 – Temperature and Humidity Universal Power Supply Options • Fully integrated, dual-redundant (optional) power supplies • Universal high-voltage range: 88-300VDC [...]

  • Page 7

    7 © 2008 RuggedCom Inc. All rights re served Rev106 3.2 Ethernet Panel Description Each Ethernet module is equipped with two LEDs that i ndicate link/activity status information. The LED will be solid for ports with link, and wi ll blink for activity. The diagram in Figure 1 highlights the port and the associated link/activity LED. Figure 1: Ether[...]

  • Page 8

    8 © 2008 RuggedCom Inc. All rights re served Rev106 3.2.1 Fiber Optical Transceive r Orientation and Connection Depending on the order code of the product, the M2000 series products can be equipped with several different types of fiber optic ports. The Transmit (TX) and Receive (RX) connections of each port must be properly connected and matc hed [...]

  • Page 9

    9 © 2008 RuggedCom Inc. All rights re served Rev106 3.3 Display Panel Description The M2000 series products are equipped with a versatile display panel, shown in Figure 5, which is designed to provide quick status information for eac h port, as well as the entire device to allow for simple diagnostics and troubl eshooting. It features: • RS232 c[...]

  • Page 10

    10 © 2008 RuggedCom Inc. All rights re served Rev106 The port-based LEDs can be cycled between three display modes: Status, Duplex, and Speed. Pushing the mode button causes the display mode to be cycled. Mode Colour Description Green (Solid) Link Green (Blinking) Activity Status Off No link Green (Solid) Full-Duplex operation Orange (Solid) Half-[...]

  • Page 11

    11 © 2008 RuggedCom Inc. All rights re served Rev106 4 Inst allation 4.1 Panel Mounting The M2000 series products can be ordered with Panel mount chassis. This option involves the use of the panel adapters to be mounted on each side of the chassis enclosure. See Figure 6 for a Panel mount diagram. Figure 6: M2100 Panel Mounting Diagram[...]

  • Page 12

    12 © 2008 RuggedCom Inc. All rights re served Rev106 4.2 Power Supply Wiring and Grounding Figure 7: M2000 Series Philips Screw Terminal Block The M2000 Family supports dual redundant power s upplies – “Power Supply 1 (PS1)” and “Power Supply 2 (PS2)”. The connections for PS1, PS2 and t he fail-safe relay are located on the terminal bloc[...]

  • Page 13

    13 © 2008 RuggedCom Inc. All rights re served Rev106 Terminal # Description Usage 1 PS1 Live / + PS1 Live / + is connected to the posit ive (+) terminal if the power source is DC or to the (Live) terminal if the power source is AC. 2 PS1 Surge Ground PS1 Surge Ground is connected to the Chassis Ground via a jumper on the terminal blo ck. Surge Gro[...]

  • Page 14

    14 © 2008 RuggedCom Inc. All rights re served Rev106 4.2.1 AC Power Supply Wiring Ex am ples Figure 8: AC Power supply wiring examples NOTES: 1. 100-240VAC rated equipment: A 250VAC appropria tely rated circuit breaker must be installed within 3m of unit. 2. Equipment must be installed according to the applicable country wiring codes. 3. When equi[...]

  • Page 15

    15 © 2008 RuggedCom Inc. All rights re served Rev106 4.2.2 DC Power Supply Wiring Ex am ples Figure 9: DC Power supply wiring examples NOTES: 1. 88-300VDC rated equipment: A 300VDC appropria tely rated circuit breaker must be installed within 3m of unit. 2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies. 3. For dual DC[...]

  • Page 16

    16 © 2008 RuggedCom Inc. All rights re served Rev106 4.2.3 Dual Power Suppl ies – DC and AC Inputs Figure 10: DC And AC power supply wiring examples NOTES: 1. 88-300VDC rated equipment: A 300VDC appropria tely rated circuit breaker must be installed within 3m of unit. 2. 100-240VAC rated equipment: A 250VAC appropria tely rated circuit breaker m[...]

  • Page 17

    17 © 2008 RuggedCom Inc. All rights re served Rev106 4.3 Dielectric Strength (HIPOT) Testing For dielectric strength (HIPOT) testing in the fiel d, users must remove the metal jumper located on terminal 2, 4, and 6 of the power supply terminal block. This metal jumper connects transient suppression circuitry to chassis ground and must be removed i[...]

  • Page 18

    18 © 2008 RuggedCom Inc. All rights re served Rev106 4.4 Failsafe Alarm Relay Wiring and Specifications The “Failsafe” output relay is provided to signal critical error conditions that may occur on the M2000 series switches. The contacts are energi zed upon power up of the unit and remain energized until a critical error occurs. Th e proper re[...]

  • Page 19

    19 © 2008 RuggedCom Inc. All rights re served Rev106 4.5 Console Port Wiring A RS232 console port for configuration and m anagement of the device is located on the LED display module shown in Figure 13. This port is intended to be a temporary connection during initial configuration or troubleshoot ing and allows for direct acce ss to the serial-ba[...]

  • Page 20

    20 © 2008 RuggedCom Inc. All rights re served Rev106 4.6 Twisted-Pair Data Ports 4.6.1 Micro-D Twisted-Pair Data Ports The M2100 may have several 10/100/1000BaseTX por ts that allow connection to standard CAT-5 UTP cable with Micro-D connectors. Figure 15 shows the Micro-D port pin configuration. Pi n Si gnal 1T X + 2 No C o nne c t i o n 3 No C o[...]

  • Page 21

    21 © 2008 RuggedCom Inc. All rights re served Rev106 4.6.2 RJ45 Twisted-Pair Data Ports The M2100 series switches may have several 10/100BaseTX ports that allow connection to standard CAT-5 UTP cable with RJ45 male connectors. The RJ45 receptacles are directly connected to the chassis ground and can accept shielded CAT-5 cables. If shielded cables[...]

  • Page 22

    22 © 2008 RuggedCom Inc. All rights re served Rev106 4.6.3 Protection on Tw isted-Pair Data Ports RuggedCom does not recommend the use of CAT-5 c abling of any length for critical real-time substation automation applications. However, trans ient suppression circuitry is present on all copper ports to protect against damage from elec trical transie[...]

  • Page 23

    23 © 2008 RuggedCom Inc. All rights re served Rev106 4.7 Gigabit Ethernet 1000Base-T X Cabling Recommendations The IEEE 802.3ab Gigabit Ethernet standard defines 1000Mbit/s Ethernet communications over distances of up to 100 meters using 4 pairs of category 5 (or higher) balanc ed unshielded twisted- pair cabling. For wiring guidelines, system des[...]

  • Page 24

    24 © 2008 RuggedCom Inc. All rights re served Rev106 5 T echnical S pecifications 5.1 Power Supply Specifications Input Range Max. Power Consumption 3 Power Supply Type Min Max Fuse Rating 10/100TX FE Ports Worst Case 12 – 24 VDC 10 VDC 36 VDC 6.3A(F) 2 24 VDC 18 VDC 36 VDC 5A(F) 2 48 VDC 36 VDC 59 VDC 2A(T) 2 HI (125/250 VDC) 1 HI (110/230 VAC)[...]

  • Page 25

    25 © 2008 RuggedCom Inc. All rights re served Rev106 5.3 Networking Standards Supported Parameter 10Mbps Ports 100Mbps Ports 1000Mbps Ports Notes IEEE 802.3 9 10BaseT / 10BaseFL IEEE 802.3u 9 100BaseTX / 100BaseFX IEEE 802.3z 9 1000BaseSX/LX IEEE 802.3ab 9 1000BaseTx IEEE 802.3x 9 9 9 Full Duplex Operation IEEE 802.1D 9 9 9 MAC Bridges IEEE 802.1Q[...]

  • Page 26

    26 © 2008 RuggedCom Inc. All rights re served Rev106 5.5 Fiber Optical Specifications The following sections detail fiber optical specif ications on ports that can be ordered with the M2100 series Ethernet switch. The user determines the type of optic s at time of ordering, and can determine the modules installed on a particular unit by reading th[...]

  • Page 27

    27 © 2008 RuggedCom Inc. All rights re served Rev106 5.5.2 Gigabit Ethernet (1000Mbps) Modul es For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optical communications. The following t able details fiber optic specifications based on the 2-port modules or pluggable transceiv ers selected at [...]

  • Page 28

    28 © 2008 RuggedCom Inc. All rights re served Rev106 5.6 Type Test Specifications Electrical Safety Levels Comments Dielectric Withstand 2 kV RMS for 1 minute ANSI/IEEE C37.90 (1989) IEC 60255-5 (Section 6) High Voltage Impulse 5 kV peak IEC 60255-5 (Section 8) Insulation Resistance 500 VDC for 1 minute IEC 60255-5 (Section 6 Electrical Environmen[...]

  • Page 29

    29 © 2008 RuggedCom Inc. All rights re served Rev106 5.8 Mechanical Specifications Parameter Value Comments Dimensions 19.00x 14.5 x 2.02 inches (482.6)x (368.3) x (51.3) mm (Length x Width x Height) with mounting brackets installed Weight 11.2 lb (5 Kg) with mounting brackets installed Enclosure 18awg galvanized steel Figure 17: Mechanical Dimens[...]

  • Page 30

    30 © 2008 RuggedCom Inc. All rights re served Rev106 6 Agency Approvals Agency Standards Comments CE EN 60950, EN 61000-6-2 CE Compliance is claimed via Declaration of Self Conformity Route FCC FCC Part 15, Class A Passed CISPR EN55022, Class A Passed FDA/CDRH 21 CFR Chapter 1, Subchapter J Passed IEC/EN EN60825-1:1994 + A11:1996 + A2:2001 Passed [...]