The rules should oblige the seller to give the purchaser an operating instrucion of Roberts Gorden 300, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Roberts Gorden 300 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Roberts Gorden 300. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Roberts Gorden 300 should contain:
- informations concerning technical data of Roberts Gorden 300
- name of the manufacturer and a year of construction of the Roberts Gorden 300 item
- rules of operation, control and maintenance of the Roberts Gorden 300 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Roberts Gorden 300 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Roberts Gorden 300, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Roberts Gorden service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Roberts Gorden 300.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Roberts Gorden 300 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation, Operation & Ser vice Manual Models UHA[S] 150, 175, 200, 225 250, 300, 350, 400 P / N 1111 0 1 N A 1 0 / 0 7 R e v . D UHA-Series T ubular Unit Heaters (Standard Range) W ARNING FOR Y OUR SAFETY If you smell g as: 1 . Open windo ws. 2. DO NO T try to light an y appliance. 3. DO NO T use electrical s witches. 4. DO NO T use any t e[...]

  • Page 2

    [...]

  • Page 3

    © 2007 R ober ts-Gordon, LLC All rights reserved. No part of this work cover ed by the cop yr ights her ein may be r eproduced or copied in any form or by any means - graphic, electr onic, or mechanical, including photocop ying, recor ding, taping or inf ormation stor age and retrie val sy stems - w ithout the writt en per mission of R ober ts-Gor[...]

  • Page 4

    [...]

  • Page 5

    TABLE OF FIGURES Figur e 1: Installation Clearances and Clearances to Comb ustibles ..................... .............. .............. ............ 4 Fi gure 2: Suspension Methods .......................... .............. ......... 6 Figur e 3: V ent and R oof Detail .... .............. ........... ............ ......... 9 Figur e 4: Standard V en[...]

  • Page 6

    [...]

  • Page 7

    SECTION 1: H EATER S AF ETY 1 SECTION 1: HEATER SAFETY Y our Saf et y is Important to Us! This sy mbol is used thr oughout the manual t o notify you of possib le fir e, electrical or burn hazar ds. Please pa y special at tention when r eading and f ollowing the w ar nings in these sections. Installation, Service and Annual Inspection of heat er mus[...]

  • Page 8

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 2 SECTION 2: INSTALLER RESPONSIBILITY The installer is r esponsible for the f ollow ing: • T o install the heat er , as well as the g as and electrical supplies, in accor dance with applicab le specifications and codes . Rober ts-Gor don r ecommends the installer cont ac[...]

  • Page 9

    SECTION 3: C RITIC AL C ONSIDERATIONS 3 SECTION 3: CRITICAL CONSI DERATIONS 3.1 Basic Inf ormation UHA(S) heater s hav e automatic ignition b ur ners f or ON/OFF operation only . 3.2 Location and Suspension All models: • Must be inst alled indoors . • Must be inst alled in a le v el position wi th horizontal d ischarge . • Ma y be mount ed on[...]

  • Page 10

    W ARNING Fire Hazard Some objects will catch fire or explode when placed close to heater . Keep all flammable objects, liquids and vapors the required clearances to combustibles a way from heater . Failure to follo w these instructions can result in death, injury or property damage. COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVI[...]

  • Page 11

    SECTION 4: N ATIONAL S TANDARDS AND A PPLICABLE C ODES 5 SECTION 4: NATIONAL STANDARDS AND APPLICABLE CODES 4.1 Gas Codes The type of gas appearing on the nameplat e must be the type of gas used. In stallation must comply with nationa l and local codes and requir ements of the local gas compan y . Unit ed Stat es: Ref er t o NFP A 54/ANSI Z223.1 - [...]

  • Page 12

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 6 SECTION 5: MAJOR COMPONENTS 5.1 Gener al Heater s are designed f or installation abo v e 6' (1 .8 m). These heater s must be installed w ithin the heated space. D uct delivery sy stems a re not permitt ed with axial f an units. W hen handling or suppor ting the heat[...]

  • Page 13

    SECTION 6: V ENTI NG 7 SECTION 6: V ENTING 6.1 V enting This heat er must be v ented in accor dance with the rules contained in this man ual and w ith the f ollowing national codes and an y state , pro vincial or local codes which ma y apply: United States: Re f e r to NFP A 54/ANSI Z223.1 - latest r evision, National F uel Gas C ode; Canada: R ef [...]

  • Page 14

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 8 6.2.2 Separ ated Comb ustion Heater s (Models UHA S 150 - 400) The heat ers ar e designed to b e installed as separat ed combustion heat ers. Th e vent a nd air intak e are run as separat e pipes t o the wall or roo f te r mi nal s. See P age 1 2, F igure 8 . As an optio[...]

  • Page 15

    SECTION 6: V ENTI NG 9 6.7 V ent Mat erial V ent material may be single w all 26 ga. (minimum) gal vaniz ed steel or equal thic kness stainless st eel. Comp letely seal all joint s, r efer t o Pa g e 7 , Section 6.2 . If penetrating a comb ustible w all or roof , a listed thimbl e with 2" (5 cm) clear ance must be used. Wher e local codes perm[...]

  • Page 16

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 10 F igure 5: Standar d V ented Heat er - Common V er tical V ent T er mination Roof 1 8" (46 cm) Min. T ype "B" vent cap (7" or 8") may be used. (These are not a vailable from R ober ts-Gordon.) Roof Flashing Appro ved Thimble (If Applicable) T yp[...]

  • Page 17

    SECTION 6: V ENTI NG 11 F igur e 6: Separat ed Combustion Heat er - V ertical and Horizontal V ent T ermination V ent T er mination Listed Thimble thr ough Comb ustible Wall V ent 1 2" (31 cm) Minimum from wall to v ent ter mination. Air Intak e Condensat e T rap to Drain (Optional) 1 2" (31 cm) Minimum from air inlet t o vent termination[...]

  • Page 18

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 12 F igure 8: Concen tric V ertical and Horiz ontal V ent T er mination V ent Air Int ake* Concentric V ent Bo x V er tical Option 1 0' (3 m) Maximum Horizontal Option Concentric V ent Bo x V ent Comb ustion Air T erminal V ent T er minal with Baf fle Plat e Flashing [...]

  • Page 19

    SECTION 7: A IR S UPPLY 13 SECTION 7: AIR SUPPLY 7 .1 Separ ate d Combustion In stallation When installed as a separ ated comb ustion heat er , the air f or combustion is dra wn in from outside the buildin g. It is important to ensur e that there is adequat e space around heater t o pro vide air f or the axial air distribution f an. 7 .2 Un vent ed[...]

  • Page 20

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 14 SECTION 8: GAS PIPING W ARNING Fire Hazard Connect gas supply according to Figure 9. Gas can lea k if not installed properly . Failure to follo w these instructions can result in death, injury or property damage. Fire Ha za rd Connect gas supply according to Fi g ur e 9[...]

  • Page 21

    SECTION 9: W IR I NG 15 SECTION 9: WIR ING W ARNING Electrical Shoc k Hazard Disconnect electrical power and gas supply before servicing. This appliance must be connected to a properly grounded electrical source. Failure to follow these instructions can result in death or electrical shoc k . All heater models r equir e constan t 1 20 V 60 Hz 1Ø po[...]

  • Page 22

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 16 9.3 UHA(S) Series Int ernal W iring Dia gram BLUE BLACK BLACK ORANGE ORANGE YELLOW BROWN BLACK WHITE WHITE L2 L1 ORANGE ORANGE BLACK BLACK GREEN WHITE WHITE GREEN GREEN BLUE BLACK BLACK BLACK WHITE GREEN BLUE GREEN YELLOW 24 VAC HOT GROUND FLAME BLACK BLACK BLACK 6 3 4 [...]

  • Page 23

    SECTION 9: W IR I NG 17 9.4 UHA(S) Ser ies Ladder Wir ing Diagr am FLAME SENSOR PRESSURE SWITCH THERMOST A T CONNECTION 6 3 4 5 2 1 1 2 0 VAC TRANSFORMER COMBUSTION BL O WER CIRCULA TION F AN CIRCULA TION F AN UH 300, 350, 400 Only GAS VA LV E ELECTRODE IGNITION MODULE FLAME SP ARK LIMIT SWITCH LIMIT SWITCH (UH 300, 350, 400 ONL Y) MANUAL RESET LIM[...]

  • Page 24

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 18 9.5 Electrical Connec tion to the Hea ter BX Connect or Junction Bo x Fle xible C onduit Burner Connect wir es together with suitab le approv ed wir e connect ors . Green t o Ground Whit e to L2 Black t o L1 L1 L2 Ground Black Whit e Green Note: J unction box is not pro[...]

  • Page 25

    SECTION 1 0: O PERATION AND M AINT ENANCE 19 SECTION 1 0: OPER ATION AND MAINTENANCE Installation, service, and ann ual inspection of the heat er must be done b y a contract or qualified in the installation and service of gas-f ired heating equipment. R ead this manu al carefully bef ore installation, oper ation, or ser vice of this e quipment. All[...]

  • Page 26

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 20 F igure 1 0: Aut omatic Burner Control Sequence Burner Sequence for Ignition Contr ol Flame Signal Start Gas V alv e Ignition Spark Thermostat 24 V SHUT DO WN RU N ST ART ts = 1 0 seconds Signals Output By Contr ol Requir ed Incoming Signals Flue F an P ressure Sw itch [...]

  • Page 27

    SECTION 1 0: O PERATION AND M AINT ENANCE 21 1 0.2.2 Start-Up the Gas V alv e (All Gases) 1 0.2.2.1 Chec k Burner Gas P ressur e 1 . R emov e the plug in the outlet (burner) pressur e test point and connect a pr essur e tap and a manom et er . 2. With the b ur ner f iring, measur e the pressur e on the manomet er . T o adjust the b ur ner pressur e[...]

  • Page 28

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 22 SECTION 1 1: USER INSTRUCTIONS 1 1 .1 User Instr uctions The UHA(S) Series heater s are fully aut omatic and operat e from the e xternal controls f itt ed on site . W ARNING Electrical Shoc k Hazard Disconnect electrical pow er before servicing. Failur e to follo w thes[...]

  • Page 29

    W ARNING FOR Y OUR SAFETY If you smell g as: 1 . Open windo ws. 2. DO NO T try to light an y appliance. 3. DO NO T use electrical s witches. 4. DO NO T use any t elephone in your b uilding. 5. Leav e the build ing. 6. Immediatel y call your local gas supplier af ter leaving the b uilding. F ollow the gas supplier  s instructions. 7 . If you cann[...]

  • Page 30

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 24 SECTION 1 2: SER VICING 1 2.1 Ser vicing Instr uctions Af ter start-up, the heat er will re quire maint enance to be carried out annually . If the heat er is used in a dir ty or dust y ar ea, more fr equent maintenance ma y be necessary . W ARNING Cut Hazard T urn off g[...]

  • Page 31

    SECTION 1 2: S ERVICING 25 1 2.8 Maintenance Checklist W ARNING Explosion Hazard Service and annual inspection must be done b y a contract or qualified in the installation and service of gas-fir ed heating equipment or your gas supplier . T urn of f gas and electrical supplies bef ore performing service or maintenance. Failur e to follo w these ins[...]

  • Page 32

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 26 Burner Observ ation Win dow Mak e sure it is clean and fr ee of crac ks or holes. Clean and r eplace as r equired. Combu stion F an Scroll, Wheel and Mot or Compr essed air or a vacuum clea ner ma y be used to clean dust and dir t. Inshot Burner s and Orif ices Clear of[...]

  • Page 33

    SECTION 1 3: T R OUBLESHOOTING 27 SECTION 1 3: T R OUBLESHOOTING 1 3.1 General Ensure pr oper air flow clearance f or axial fan. Open louver s slightly . Replace axial f an if it does not operate . If prob lems persist, contact Roberts-Gordon, LLC at www .rg-inc.com Heater Operating TROUBLESHOO T ENDS. No Replace limit switch. The limit s witch has[...]

  • Page 34

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 28 1 3.2 T r oubleshootin g F or A uto matic Ignition Burner S yst ems If prob lems persist, contact Roberts-Gordon, LLC at www .rg-inc.com Heater Operating TROUBLESHOO T ENDS. No T race fault in supervision sy stem. See T roubleshooting for Flame Supervision Sy stem secti[...]

  • Page 35

    SECTION 1 3: T R OUBLESHOOTING 29 1 3.3 T r oubleshooting f or Flame Supervision S yst em NO TE: Minimum flame pr obe current 1 μA DC . T ypical flame pr obe current 3-5 μA DC . Repair or r eplace as necessary . If prob lems persist, contact Roberts-Gordon, LLC at www .rg-inc.com Replace ignition contr ol. Use General T roubleshooting section to [...]

  • Page 36

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 30 1 3.4 T r oubleshooting fo r Gas V alv es V alve f ault y . Replace with one of correct type. F ault elsewhere. Corr ect pressure pr oblem. If prob lems persist, contact Roberts-Gordon, LLC at www .rg-inc.com V alve Oper ating TROUBLESHOO T ENDS. No Ye s V alve or ignit[...]

  • Page 37

    SECTION 1 4: R EPLACEMENT P ARTS 31 SECTION 1 4: REPLACEMENT P AR TS See warnings and not es on P age 24, Section 1 2 bef ore remo ving or replacing par ts . Burner Componen ts All ser viceab le burner par ts are accessed b y the door on the side of the heat er . Remo v e the sheetmetal scr ews. 1 4.1 Gas V alve R emov e the gas supply pipe at the [...]

  • Page 38

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 32 1 4.2 Burner Compartment Remo ve f le xible air duct from spigot Remo ve access plate Remo ve scr ews and pull of f burner cov er View ing por t for f lame probe View ing por t for ignition electr ode Flame probe Burner compar tment cov er Rubber Seal Ignition electrode[...]

  • Page 39

    SECTION 1 4: R EPLACEMENT P ARTS 33 1 4.3 Ignition Electrode and Flame P robe Flame P robe Ignition Electrode Remo ve Sc rew Ignition Electrode Burners Flame P robe Burners Burner Compar tment F ront Views Remo ve all burner compar tment scre ws to remo ve the burner compar tment and access the "F ront View". Limit Thermostat .1 20 (3 mm)[...]

  • Page 40

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 34 1 4.4 Combustion F an V er tical Installation V ent Box Outlet Gasket Flue Fan V ent Box Screws Flue Adapter Flue Adapter to Flue Fan screws Rear Panel Hole Disconnect electrical connections at plug in tabs. Mounting Plate to V ent Box Screws Mounting Plate Gasket Air P[...]

  • Page 41

    SECTION 1 4: R EPLACEMENT P ARTS 35 1 4.5 Pr essure S witch P ull of f 3 wa y connector . Spring open plastic clips of mounting cradle . Repla ce with correct type of pr essure s witch f or model. The pr essure s witches are colo r coded f or each pressur e set ting. Carbon M onoxide Hazard Use correct pressure switch specified for each model. Use [...]

  • Page 42

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 36 1 4.6 Ignition Control The contr ol mounts t o the electrical plate . P ull out ignition cab le and w iring from boar d, noting their positions. Re lease the f our mounting st andof fs. Ref it in re ver se. Ensur e correct location of ignition cabl e and all other w iri[...]

  • Page 43

    SECTION 1 5: S PECIFICATIONS 37 SECTION 1 5: SPECIFICATIONS 1 5.1 Standard (Models 1 50 - 40 0) UHA(S) Series Dimension Data A B Rear View End View Z 25 1/2" (65 cm) 6 1/2" (17 cm) Gas Supply F G H T op View I E C D 77 Heater must be supported at these points from abov e or below . 19 3/8" (49 cm) Support Center s 4 x 3/8" Capti[...]

  • Page 44

    COMB A T ® UHA U NIT H EATE R I NSTALLATION O PERATION AND S ERVICE M ANUAL 38 1 5.2 General T echni cal Data T able (All Models) Model UHA[S] 15 0 UHA[S] 17 5 UHA[S] 20 0 UHA[S] 225 UHA[S] 250 UHA[S] 30 0 UHA[S] 350 UHA[S] 40 0 F ull Load Amps @ 1 15 V A 5.8 5.8 10 . 6 10 . 6 10 . 6 11 . 6 11. 6 11 . 6 Air V olu me CFM 2245 2245 37 1 6 371 6 3716[...]

  • Page 45

    SECTION 1 6: T HE RO BERTS GORDON ® COMB A T ® UHA-S E - 39 SECTION 1 6: THE ROBERTS GORDON ® COMB A T ® UHA -SERIES W ARRANTY ROBER TS-GORDON WILL P A Y FOR : Wit hin 24 months fr om dat e of pur chase by b uyer or 27 months fr om dat e of shipment b y Rober ts-G ordo n (whichev er comes first), r eplacement par ts w ill be pro vided free of c[...]

  • Page 46

    [...]

  • Page 47

    [...]

  • Page 48

    10 ' (3 m) W ARNING © 2007 Roberts-Gordon, LLC www.rg-inc.com Printed in U .S.A. P/N 91040031 Re v B At tach this infor mation to the wall near the R OBERTS GORDON ® heater Read the Installation, Operation and Service Manual thoroughl y befor e installation, operation or service. OPERA TING INS TRUCTIONS 1 . STOP! R ead all safety instructio[...]