Rinnai 16e manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Rinnai 16e, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Rinnai 16e one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Rinnai 16e. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Rinnai 16e should contain:
- informations concerning technical data of Rinnai 16e
- name of the manufacturer and a year of construction of the Rinnai 16e item
- rules of operation, control and maintenance of the Rinnai 16e item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Rinnai 16e alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Rinnai 16e, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Rinnai service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Rinnai 16e.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Rinnai 16e item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Inst allation and User Manual Infinity 16e Infinity 16e Continuous Flow W ater Heater Import ant. Read these instructions carefully befo re attempting installation or use of this appliance. All work must be carried out by competent persons.[...]

  • Page 2

    2 RINNAI UK W ARRANTY As the purcha ser of th is high quality Rinnai Water H eater y ou are provided with th e following co nditional g uarantee. Definition of S tandard Use. The warranty period allocated under Standa rd Use is base d on Domestic and Lig ht Commercial hot water usage. Rinnai Stand ard Use warranty periods apply only where Rinnai wa[...]

  • Page 3

    3 CONTENTS Rinnai UK W arranty..…………………….. Unpacking Rinnai Water Heater… ……… Installation Ins tructi ons………… ………… Flue R equire ments… …………… ………... Dim ens ion s……………… ………… ……… Te chnic al D eta ils. .……… ………………… Featur es and Benefit s………[...]

  • Page 4

    4 UNP ACKING RINNAI W A TER HEA TER • After unpacking the ap pliance check for damage, if the heater is damaged contact your supplier immediately . Do not install a damaged appliance be fore checking with y our supplier. • One remote control an d heater accessories pack are inside the car ton. • Check that the appliance supplied is the correc[...]

  • Page 5

    5 IMPORTA NT IN FORMA TION 1. Gas safety (Install ation & Use) r egulations 19 98 are the ‘ Rules in fo rce’. In y our own i ntere st an d that of sa fety, it is law that all g as appl ianc es are inst alled by compe tent p erson s in acco rdanc e with the a bove regul ations . Fail ure to ins tall appliances correctly c ould lead t o prose[...]

  • Page 6

    6 Gene ral In sta llatio n Info rmation . External Installations. The Rinnai Inf inity 16e is for exte rnal mounting onl y. The unit i s classed as a Catego ry A3 flueles s appliance as described by CEN CR1 749. Although BS 5440 d oes not relate di rectly to heaters in this category the rules must be follow ed wh en posi tioni ng th e appli ance, e[...]

  • Page 7

    7 INST ALLA TION INSTRUCTIONS - CONNECTIONS Water Sup ply . Where the wa ter s upply press ure exceed s 10 bar, an ap prov ed pr essure redu cing device is r equired at t he inlet of the applian ce. To a chieve the r ated flow a minim um water s upply press ure o f 0.8 bar is requi red a t the applian ce in let. Th e unit will o perate at lower s u[...]

  • Page 8

    8 Dimension Ter minal Position Distance A Directly bel ow an opening , air brick, o pening windo ws, etc. 300mm B Abov e an o penin g, air brick , open ing wi ndo w, etc. 300m m C Horiz ontally to an op ening, air bric k , opening windo w, etc. 300mm D Be low gutte rs, soil pip es or dr ain pip es. 75mm E Below eaves. 200mm F Below balconi es or ca[...]

  • Page 9

    9 DIMENSIONS[...]

  • Page 10

    10 TECHNICAL DET AILS * Facto ry Settin g **M inimum operation flow based on te mperatu re setpoi nt and inlet condi tions . Infinity M odel Infi nity 16e Units Installati on External Nat Gas Press Low 1.8 mbar Nat Gas Press High 8.8 mbar LPG P ress Low 1.8 mbar LPG P ress Hig h 8.1 mbar Heig ht 530 mm W i dth 35 0 mm Dept h 170 mm We i gh t 1 5 kg[...]

  • Page 11

    11 Congr atulatio ns on pu rchasi ng the T echnol ogica lly Adv anced , Temper ature Control led, Rinnai Hot W ater Sy stem. • The Ri nnai Infinit y 16e NEVER RUNS OUT of hot water . As long as el ectrici ty, water, and g as su ppli es are conn ected, hot wate r is av ailabl e wh en hot water taps are open. • Built into the main micro -processo[...]

  • Page 12

    12 Excessively hot water is dangerous, especially for young c hildren and t he infirm . The water heate r allows y ou to control the t emperature of your hot water to saf e levels. Do stay with childr en whenever th ey are in t he bathroom. Do take them o ut of the b athroom if you need to answer the phone or door. Do test the temperatu re of the w[...]

  • Page 13

    13 IMPORT ANT INFORMA TION Alwa ys c heck wate r temp eratu re be fore use. Refer to wa rning about hot water on page 12 f or impo rtant safe ty info rmation. Hot water may go out without wa rning at low water flows. The I nfin ity 16e controls the wate r temperat ure a utomat ically. For h igh temperat ures it may red uce the fl ow. The wat er fr [...]

  • Page 14

    14 Rinnai Infinity product s have no pilo t light a nd when install ed without Tempe rature Controllers, the applia nce will operate automati cally as soon as a hot water tap is opened . The burne r ignites wi th elect ronic igniti on and t he flame exting uishes as soon as w ater flowing through the appliance stops. T u rn On by opening the hot wa[...]

  • Page 15

    15 TEMPERA TURE CONTROLS - GENERAL When deciding on the best positi on for the temperature c ontrols, the f ollowing points should be take n into accou nt. • Fi t t he con tro ls out of r eac h of ch il dre n ( sugg es te d he ig ht from the f loo r 1 .5 m.) • Avoid po sitions wh ere the contro llers will become hot. Do not fit them near stoves[...]

  • Page 16

    16 TEMPERA TURE CONTROLS - INST ALLA TION Universal Tem perature Controller MC-91-1A 1. Determin e the mo st suitable positio n for t he temperat ure contro ller. 2. Drill 3 h oles i n the wall as show n in fi g. 1, o ne for th e cabl e a nd two for the s ecuri ng sc rews . Ensure holes are drill ed deep enough. Fit wall plug s if need ed. (e nsu r[...]

  • Page 17

    17 TEMPERA TURE CONTROLS - INST ALLA TION Conn ect ing O ne o r Tw o Co ntro lle rs 1. Iso late the pow er suppl y. 2. Remov e the f ront cover from the A pplia nce (4 scr ews) fig. 1. 3. Thread the cable through th e cable acces s hole at the ba se of th e app lianc e. 4. Connect th e spade conne ctors to t he ter minals marke d "Re mote C on[...]

  • Page 18

    18 TEMPERA TURE CONTROLS The purpose of a Te mperature Cont roller is to enable the us er to hav e complete c ontrol over the hot water su pply. Used cor rectly, the hot water u nit will supply hot wat er at the temper ature selec ted, eve n when the wate r flo w is var ied, or when more th an one tap is used. Adjust ments to the operatio n of your[...]

  • Page 19

    19 Remote temperatur e controllers a re a feature t hat provides cont rol over the water temperatu re. Rinnai Infinity wa ter heaters can be operate d with 1, 2, 3 or no temperatu re controllers. The Univ ersal controller M C-91-1A c omes as sta ndard with all Infinity wa ter heaters. NOTE: Each time a butt on is presse d, a BEEP will sound. The BE[...]

  • Page 20

    20 TEMPERA TURE CONTROLS - OPERA TING Using 1 Universal T emperature Controller . Press the On/O ff but ton on the tem perat ure contr oller. The ON indicato r will glow on the Temperature Controller. This in dicates th at the he ater is re ady t o supply hot wate r when a tap is opened. A djustin g Tem pera ture Simply pres s the H ot Wat er Tempe[...]

  • Page 21

    21 Using 2 or more Uni v ersal T emperature Controllers. Switching the sy stem ON. Using hot water. Bath room t empera tures should be no more than 50 0 C. The ho t wate r system a nd a ll contro llers can be switched ON and OFF f rom any cont roller by pressin g the On/Of f button as sho wn. W hen the s ystem is turned O N the w ater tempe rature [...]

  • Page 22

    22 Using High T em perature Display Controllers. You will need to program th e Master cont roller if y ou want to dis play and us e temperatures over 50 0 C. Program ming only needs to be done on M aster universal controllers; other univers al controllers will not a llow this, and Delu xe Kitchen Controllers are su ppli ed al ready prog ramme d to [...]

  • Page 23

    23 Note T o turn off your hot water syst em. Additional safety features. During normal operati on the system is left on. To turn the system off simply press the On/O ff button on any t emperature controller (wher e fitted). This will shut the w ater heate r down comple tely incl uding the te mpera ture contr oller digital display . The on i ndicato[...]

  • Page 24

    24 TEMPERA TURE CONTROLS - INFORMA TION Do not pus h the On /Off bu tton on the Master c ontroller aft er transf erring p riority of te mperat ure s elect ion t o a S econda ry controller as the system will shut dow n. Do Not Turn OFF the Ma ster Controll er Temp eratu re prio rity c an not be switc hed to an other cont roller whe n the w ater i s [...]

  • Page 25

    25 TESTING 1. Purge gas, h ot wate r and col d water s upply lines be fore makin g the fi nal conn ection of the water heater. Swarf in either the gas or water supplie s may cause damage . 2. Turn on ga s and cold water sup plies. 3. Test for wat er leak s and ga s escap es ne ar the uni t. 4. Isolate gas and electric suppl y. Rem ove te st point s[...]

  • Page 26

    26 GAS PRESSURE SETTING The wo rking g as pressure on the wate r heater is e lectron ica lly contro lled and factory set. Under nor mal ci rcum stanc es it does not re quire adjustment during insta llation. Perfor m this procedure only if the unit is not operating correctly and all oth er possi ble ca uses for incorrect operation ha ve been elimi n[...]

  • Page 27

    27 GAS PRESSURE SETTING 11 .Re move ru bber ac cess pl ug an d ad ju st t he regula tor sc rew on t he mod ulati ng v alve (f ig. 4) as re quired to the press ure b elow. 12.Loc k the reg ulati ng screw on the modu latin g val ve. 13.Set the appliance to ' Forced High' combust ion by setting both no. 3 and no. 4 dipswitch es of the bot to[...]

  • Page 28

    28 DIP SWITCH SETTING Dip Switch Positions Explained OFF ON SW2 (top) 1 - Gas Type LEGEND: 2 - Temperature Black Section indicat es 3 - Temperature position of dip switch. 4 - Temperature OFF ON OFF ON OFF ON SW1 (bottom) 1 - Computer Programming 2 - Computer Programming OFF ON 3 - Combustion 4 Combustion Dip Swiches Explained GA S TYPE LPG NA T GA[...]

  • Page 29

    29 DIP SWITCH SETTING Infinity 16e T emperatures - With or Without Remotes off on SW 2 off on SW 2 off on SW 2 1 1 1 2 2 2 3 3 3 4 4 4 40 deg C 43 deg C 50 deg C off on SW 2 off on SW 2 off on SW 2 1 1 1 2 2 2 3 3 3 4 4 4 55 deg C 65 deg C 75 deg C[...]

  • Page 30

    30 ERROR MESSAGES Rinnai water heaters have the ability to check their own operation continuously. If a fault occurs, an error code will fl ash on the Di gita l Display if y ou hav e temp eratur e con troller s install ed. T his as sists with dia gnosin g the fault, and m ay ena ble y ou to ov erco me a proble m wit hout a se rvi ce call . Plea se [...]

  • Page 31

    31 ERROR MESSAGES T roubleshooting w ithout controllers If you have not installe d temper ature controllers and experien ce the foll owing symp toms, pleas e c arry ou t the sugg estion s bel ow. If s ymp toms c onti nue, pl eas e conta ct Rin nai fo r adv ice. NOTE: Faults ca used by insufficient gas /water supply or gas/water quality and installa[...]

  • Page 32

    32 REST ARTING THE RINNAI W A TER HEA TER Fol low ing a p ow er cut th e he at ers sho uld b e re sta rt ed in t hi s ma nne r. St andard system. Sin g le o r mu lt ip le w a te r he at er s w ithou t r em ot e con t ro ll er s. The heater s will auto matically rese t without any user involvem ent. Single or multi ple water heater s with remote con[...]

  • Page 33

    33 WIRING DIAGRAM[...]

  • Page 34

    34 DIAGNOSTIC POINTS Diagnost ic Poin ts- To be rea d in conju nction with the wiri ng diagram.[...]

  • Page 35

    35 SPECIFICA TION Model …… …………… …………… ………… ……..….. .....……… ……… ……….. I nfi nity 16e Insta llati on …………………… ……………… ……. ..…… .…. ..……. Extern al locat ion onl y Fuel ………… ………… …………… ……………… ..….…. .……… ?[...]