A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Riello Vision 1500, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Riello Vision 1500 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Riello Vision 1500. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Riello Vision 1500 should contain:
- informations concerning technical data of Riello Vision 1500
- name of the manufacturer and a year of construction of the Riello Vision 1500 item
- rules of operation, control and maintenance of the Riello Vision 1500 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Riello Vision 1500 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Riello Vision 1500, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Riello service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Riello Vision 1500.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Riello Vision 1500 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    [...]

  • Page 2

    2 I NTRODUCTION Congratulations on purchasi ng a UPS Vision product and welcome to Riello UPS ! To use the support service offere d by Riello UPS , visit the site www.riello- ups.com Our Company is a speci alist in the design, deve lopment and manufacturi ng of uninterruptible po wer supplies (UPS). The UPS described in th is manual is a high qu al[...]

  • Page 3

    3 C ONTENTS PRESENTATION 4  UPS V IEWS 5  F RONT VIEW 5  R EAR VIEW 6  D ISPLAY PANEL VIEW 7  INSTALLATION 8  I NITIAL CONTENT CHECK 8  I NSTALLATION ENVIRONMENT 8  USE 9  C ONNECTIONS AND SWITCHING ON FOR THE FIRST TIME 9  S WITCHING ON FROM THE MAINS 9  S WITCHING ON FROM THE BATTERY 9  S WITCHING OFF THE UPS 9[...]

  • Page 4

    4 PRESENTATION The VISION series is the ideal solution for high end user s who require high sec urity and versatility fr om their power systems. The VISION is the best protectio n system ava ilable for net work devices, servers a nd conventional stora ge systems. The VISION series is a range of UPS which utilises the very la test Line Interactive t[...]

  • Page 5

    5 UPS V IEWS F RONT VIEW Display Removable front panel Multipurpose buttons Battery pack connector ON/OFF Switch Battery pack retention panel[...]

  • Page 6

    6 R EAR VIEW 800VA / 1100VA Model 1500VA / 2000VA Model Communication port RS232 Cooling fans USB communication port IEC 10A output socket Circuit breaker Energyshare Communication Card Slots IEC 10A input plug[...]

  • Page 7

    7 D ISPLAY PANEL VIEW “SEL” button (Select) Load level indicator “ON” button Configuration area “STAND-BY” button Maintenance request Regular operation Time r Mains operation Measurement display area Battery operation Stand-by / alarm AVR active EnergyShare Battery charge indicator[...]

  • Page 8

    8 INSTALLATION I NITIAL CONTENT CHECK After opening the packaging, i t is first necessary to check the contents. The package must contain: UPS Schuko power cable - IEC 10A 2 IEC 10A connection cables USB cable RS232 cable User manual CD + Safety manual I NSTALLATION ENVIRONMENT The UPS and the Battery Box must be installed in ve ntilat ed, clean en[...]

  • Page 9

    9 USE C ONNECTIONS AND SWITCHING ON FOR THE FIRST TIME 1) Confirm that the installation upstream of the UPS is adequa tely protected against ov erloads and short ci rcuits. It is recommended that the rating of this protection is eith er 10A or 16A type B or C (depending on the UPS po wer rating), always check prior to connection. 2) Power the UPS u[...]

  • Page 10

    10 D ISPLAY PANEL MESSAGES This chapter describes, in detail, the vari ous information that can be displayed on th e LCD. UPS STATUS MESSAGES ICON STATUS DESCRIPTION Fixed Indicates a fault Flashing The UPS is in stand-by mode Fixed Indicates regular operatio n Fixed The UPS is operating from the mains Fixed The UPS is operating from the batter y .[...]

  • Page 11

    11 M EASUREMENT DISPLAY AREA The front panel can be used to display im portant UPS oper ating information. When the UPS is switched-on, the dis play shows the main voltage value. To display a different measur ement, press the “SEL” bu tton repeatedly until the des ired measurement a ppears. In the event of a fault/alarm ( FAULT) or a lock (LOCK[...]

  • Page 12

    12 C ONFIGURING THE OPERATING MODE The area of the display sh own in the figure displ ays the active operatin g mode and allo ws the user to choos e other modes dir ectly from the display panel. HOW TO PROCEED: • To access the configuration area, hold down the “SEL” button for at least 3 seconds. • The icon corresponding to the mode current[...]

  • Page 13

    13 S OFTWARE M ONITORING AND CONTROL SOFTWARE The PowerShield 3 software guarantees effective, intuitive UPS ma nagem ent, displaying all th e most important information such as input voltage, appli ed load and battery capacit y. It is also able to perform shutdown operations and send e -mails, text messages and network messages automatic ally when[...]

  • Page 14

    14 UPS CONFIGURATION The table below illustrat es all the possi ble configuratio ns available to the user in orde r to best adapt the UPS for individual requirements. It is possibl e to perfo rm these operations using the UPStools software. FUNCTION DESCRIPTION DEFA ULT POSSIBLE CONFIGURATIONS Output frequency Selects the nomina l output frequency [...]

  • Page 15

    15 C OMMUNICATION PORTS On the back of the UPS (see UPS Views ), the following communication ports are presen t: • RS232 connector • USB connector • Expansion slot for additional communication cards RS232 CONNECTOR RS232 CONNECTOR PIN # SIGNAL NOTES 1 Programmable output *: [default: UPS in lock] (*) Opto-isolated contact max. +30Vdc / 35mA. [...]

  • Page 16

    16 B ATTERY PACK REPLACEMENT The UPS is also equippe d with a dedicated batter y pack that allows for easy re placement of batteries ( hot swap ) in complete safety, than ks to the protected connection system. • WHEN THE BA TTERY PACK IS DISCONNECTED , THE LOADS CONNECTED TO THE UPS ARE NOT PROTECTED IN THE EVENT OF A MAINS FAILURE • THE BA TTE[...]

  • Page 17

    17 3. Remove the battery pack's retention pa nel carrying out the operations sho wn in the figure below. 4. Slip off the batt ery pack pulling it to wards the outside, as shown in th e figure be low. Be careful when extracti ng and lifting up the battery pack as it is heav y.. ATTENTION : the new battery pack must contain the sam e number and [...]

  • Page 18

    18 TROUBLESHOOTING Irregular UPS operation is not al ways an indication of a fault, and can be due to minor or eas y-to-resolve issues It is therefore advisable to con sult the table below as it cont ains information which is usef ul for solving the most common UPS problems. PROBLEM POSSIBLE CA USE SOLUTION THE DISPLAY DOES NOT LIGHT UP ON/OFF SWIT[...]

  • Page 19

    19 PROBLEM POSSIBLE CA USE SOLUTION THE BUZZER SOUNDS CONTINUOUSLY AND THE DISPLAY SHOWS ONE OF THE FOLLOWING CODES: A54, F50, F51, F52, L50, L51, L52 THE LOAD APPLIED TO THE UPS IS TOO HIGH Reduce the load to within the threshold of 100% ( or user threshold in the case of code A54 ). If the display shows a lock, remove the load and switch the UPS [...]

  • Page 20

    20 A LARM CODES Using a sophisticated s elf-diagnosis system, the UPS is abl e to check its o wn status for any anomalies and/or faults which may occur during norm al operation and display them on the display panel. If there is a problem, the UPS signal s the event by showing the code and the type of active alarm on the display (FAULT and/or LOCK).[...]

  • Page 21

    21 ¾ Active commands: Indicates the presence of an active remote command. CODE DESCRIPTION C01 Remote control 1 (Switch On/Off) C02 Remote control 2 (Load supplied b y the mains) C03 Remote control 3 (Switch On/Off) C04 Battery test in progress L OCK LOCK alerts are normally pr eceded by an alarm sign al and thei r scale lea ds to the powering-off[...]

  • Page 22

    22 TECHNICAL DATA UPS MODELS VST 800 VST 1100 VST 1500 VST 2000 INPUT Nominal voltage [Vac] 220 - 230 - 240 Maximum operating voltage [Vac] 300 Nominal frequency [Hz] 50 - 60 Rated current (1) [A] 3.9 5.3 7.4 9.7 BATTERY Recharge time (standard versions) [h] < 4h for 80% of the load No. of internal batteries 2 2 4 4 OUTPUT Nominal voltage (2) [V[...]

  • Page 23

    0MNVST800RUENUA[...]