A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Revox M 219, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Revox M 219 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Revox M 219. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Revox M 219 should contain:
- informations concerning technical data of Revox M 219
- name of the manufacturer and a year of construction of the Revox M 219 item
- rules of operation, control and maintenance of the Revox M 219 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Revox M 219 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Revox M 219, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Revox service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Revox M 219.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Revox M 219 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    of Dominating Ent ertainment. Revox of Switzerland . Re:connect M 219 Additional room amplifier[...]

  • Page 2

    M219 room amplifier Re:connect 1 Contents M219 Additional room amplifier Safety Installation and operation Safety measures Warranty Front view Connection plan Detailed description [1] Local IN 1 2 3 [2] PRE OUT [3] DIL Setup switches (1) IR receiver (2) Pre Out (3) Input IN (4-5) Local inputs (6-7-8) Addressing [4] M219 Link [5] IR Link [6] Input I[...]

  • Page 3

    M219 room amplifier Re:connect 2 M219 Additional room amplifier General The M219 is a digital Additional Room Amplifier from the newest M Series in the RE V OX Multiroom programme. It is used for the reproduction of music in the additional rooms in a Multiroom system and can also supply the listener with current information through an additional di[...]

  • Page 4

    M219 room amplifier Re:connect 3 Safety Please take note of the information shown on the labels on the rear of the unit. Housings should not be removed, in order to avoid the danger of an electric shock. Maintenance and repairs should only be ca rried out by qualified personnel. This symbol warns of “dangerous voltages” withi n the unit. In the[...]

  • Page 5

    M219 room amplifier Re:connect 4 Safety measures Operational anomalies In the case of any unusual noises or smells coming from the unit, remove the power cable immediately. Have the unit checked as soon as possible by your supplier. Do not open the unit The unit should not be opened because of the risk of electrocution. Periods of non-use If the un[...]

  • Page 6

    M219 room amplifier Re:connect 5 M219- Front view [A] IR Sensor The I nfra R ed sensor receiv es signals from the remote co ntrol or from any other IR control devices, such as the PDAs for the music ser ver. Switching the IR sensor off If required, the IR sensor can be switched off using the SETUP DIL switch [3] on the rear of the M219 . [B] Status[...]

  • Page 7

    M219 room amplifier Re:connect 6 Connection plan Short descriptions [1] Local Cinch inputs L/R [2] Preamp outputs L/R [3] DIL setup switches [4] M219-Link display connector [5] IR receiver or wall-mounted remote control connections [6] Switching voltage input [7] Stereo/ Mono switch [8] Multiroom Bus input [9] Multiroom Bus output [10 ] Speaker con[...]

  • Page 8

    M219 room amplifier Re:connect 7 Detailed descriptions [1] LOCAL IN 1 2 3 Local Cinch inputs L/R The M219 has 3 local line inputs for a CD player, video recorder or TV, for example, which are located directly in the room where the M219 is. The local audio inputs are activated by the Local key on the (wall- mounted) remote control. You can scroll th[...]

  • Page 9

    M219 room amplifier Re:connect 8 DIL setup switches NO Function Factory setting 1 M219 IR eye on/off On 2 Pre-Out: Fixed Volume Off 3 LOCAL IN 1  Fixed Volume Off 4 Number of local inputs On 5 Number of local inputs On 6 M219 address Off 7 M219 address Off 8 M219 address Off Please note: The switch is in the ON position when it is down You can e[...]

  • Page 10

    M219 room amplifier Re:connect 9 (2) PRE OUT Two operating modes are possible with the M219 ’s preamp output: Floating Volume (Factory setting from serial # 2 000 ): This is the standard mode setting. In this case, the PRE OUT level changes parallel to the spe aker level. This means that as you increase the volume at the speakers, for example, th[...]

  • Page 11

    M219 room amplifier Re:connect 10 (3) Voltage input IN (from serial # 2 000) Using the voltage input IN on the M219 , the local audio input LOCAL IN 1 can be activated by the applicati on of 5 – 24 VDC. This means that as soon as the voltage is present at IN , the M219 switches on automatically and selects the input LOCAL IN 1 . When the voltage [...]

  • Page 12

    M219 room amplifier Re:connect 11 Please note: SCART sockets Many devices such as SAT rece ivers, video reco rders or DVD players output a switching voltage through the SCART so cket as soon as they are switched on. On a standard SCART socket, PIN 8 outputs the posit ive voltage (+) and PIN 4 or 14 is the earth (-). L The principle of Master/Slave [...]

  • Page 13

    M219 room amplifier Re:connect 12 M219 local inputs See description: [1] LOCAL IN 1 2 3 Number of local inputs DIL switch 4 DIL switch 5 DIL position 0 Off Off 4 5 1 Off On 4 5 2 On Off 4 5 3 On On 4 5 M219 addressing If you want to control each M219 individually, to use the alarm function of the M51 T imer , for example, it is necessary to assign [...]

  • Page 14

    M219 room amplifier Re:connect 13 [4] M219-Link M217- Display connection The external display M217 can be connected to the M219-Link connector, which can give the listener basic information a bout the current music programme. Connection is made using a straight through (not cross ed), 4-core telephone cable with an RJ11 plug (6P4C-Modul ar) connect[...]

  • Page 15

    M219 room amplifier Re:connect 14 [7] CHANNEL SELECT Stereo/ Mono switch Using the Channel Select switch, you can adju st the operating mode of the two music (stereo) channels, to the requirements of the room where the M219 is installed. Three operating m odes are available: 1) Stereo The left music channel is reprodu ces through the left speaker c[...]

  • Page 16

    M219 room amplifier Re:connect 15 [8] IN RE V OX MR-BUS Multiroom Bus input Connectio n of the RE V OX Multiroom Bus cable, which is connected to the Multiroom central unit e.g. M51 MR Module MKII. Connection is made using a screened and uncrossed RJ45 cable . [9] OUT RE V OX MR-BUS Multiroom Bus output Connection for a further M219 , which is conn[...]

  • Page 17

    M219 room amplifier Re:connect 16 [10] R – L SPEAKERS Speaker connection Always use a cable of a sufficient diameter for connecting your speakers to the M219 . RE V OX recommend s: up to 15 m: Ø 1.50 mm 2 up to 30 m: Ø 2.50 mm 2 over 30 m: Ø 4.00 mm 2 We recommend not to use cables longer than 50, due to the unavoidable loss of HiFi reproducti[...]

  • Page 18

    M219 room amplifier Re:connect 17 M219 Cabling plan diagram e.g . T V Ext. Amplifier e.g. VCR Multir oom centrak unit e.g. M5 1/ MR-M odul e M KII DLC-2 Digi tal Loud speak er Co ntroller FM T une r Timer Menu SWR 3 RE OX V TUNER <> LOCA L - VOL + OFF CD SERV ER AUX2 TUNER <> LOCA L - VOL + OFF CD SERVE R AUX2 Zone 1 Zone 2 Zone 3 Zone [...]

  • Page 19

    M219 room amplifier Re:connect 18 Multiroom cabling Multiroom cabling uses a CAT 7 cable, in accordance with the international network standard EIA/TIA-568-B. This EIA/TIA-568-B standard provides for the following assignment: The CAT 7 cable is characterised by 4 twisted pairs, where each pair has its own screening. There is a comp lete screening a[...]

  • Page 20

    M219 room amplifier Re:connect 19 Technical data Amplifier part: Music power: 2 x 50 Watt at 4 Ohm / 1% THD 2 x 25 Watt at 4 Ohm / RMS Frequency range: 10 Hz - 25 kHz / -3 dB Damping factor: > 200 at 8 Ohm / 1 kHz Harmonic distortion: 0.03 % at 10 Watt General M219 data: Power voltage: 230 V 115 V Power fuse rating: 0.5 A time-lag 1 A time-lag P[...]

  • Page 21

    M219 room amplifier Re:connect 20 Guarantee The guarantee period is 24 months from the date of purchase. Your dealer should be your first contact if you need service. If he can't give you the help you need, send the M219 carriage free and without any accessories to your national Sales Office. Please supply a complete description of the problem[...]