ResMed S9 VPAP ST manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ResMed S9 VPAP ST, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ResMed S9 VPAP ST one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ResMed S9 VPAP ST. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ResMed S9 VPAP ST should contain:
- informations concerning technical data of ResMed S9 VPAP ST
- name of the manufacturer and a year of construction of the ResMed S9 VPAP ST item
- rules of operation, control and maintenance of the ResMed S9 VPAP ST item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ResMed S9 VPAP ST alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ResMed S9 VPAP ST, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ResMed service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ResMed S9 VPAP ST.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ResMed S9 VPAP ST item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Gl ob al l ea d er s i n sl ee p a nd r e sp ir a tor y me di c in e ww w.resmed.com VP AP ™ ST VP AP ™ S POSITIVE AIRW A Y PRESSURE DEVICE Welcome Guide English 368698/2 20 1 3-0 1 S9 VP AP ST / S9 VP AP S WELCOME EUR1 Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. Distributed by: ResMed Corp 9001 Spectrum[...]

  • Page 2

    Air filter DC power inlet SD card slot Module/Adapter port Air outlet VP AP at a glance The VP AP system comprises the follo wing elements: • VP AP de vice • Air t ubing • 90W po wer supply unit • tra v el bag • SD card • SD card protective folder . Optional components include: • H5i heated humidifier • Standard air tubing • SlimL[...]

  • Page 3

    Setup 1. Connect the DC plug of the pow er supply unit to the rear of the VP AP device. 2. Connect the pow er cord to the pow er supply unit. 3. Plug the other end of the pow er cord into the pow er outlet. 4. Connect one end of the air tubing firmly onto the air outlet. 5. Connect the assembled mask system to the free end of the air t ubing. Notes[...]

  • Page 4

    VP AP basics Key: Info menu Setup menu Push dial Start/Stop Climate Control Heated tube Ramp Humidity level Home Setup menu * Allows you to make changes to settings or exit from the menu. Info menu* Allows you to view your sleep statistics or exit from the menu. Push dial T urning the dial allows you to scroll through the menu and change settings. [...]

  • Page 5

    1. F rom y our HOME screen, turn until the RAMP screen is display ed in blue. 2. Press . The selection is highlighted in orange. 3. T urn until the ramp time you require is display ed. 4. Press to confirm your c hoice. Adjusting r amp time Designed to make the beginning of treatment more comf ortable, ramp time is the period during whic h the press[...]

  • Page 6

    S9 Essentials S9 Essentials is designed to make de vice interaction and menu navigation easier f or you. If enabled b y the clinician, S9 Essentials disables the Info and Set up functionality so that you can simply start and stop therapy and adjust ramp, humidification and Climate Control. Selecting the mask type T o select your type of mask: 1. Pr[...]

  • Page 7

    Getting star t ed 1. Make sure the po wer is connected. 2. Adjust the ramp time if required. 3. Fit your mask as described in y our mask user guide. 4. T o st art therapy , simply breathe into the mask and/or press . 5. Lie down and arrange the air t ubing so that it is free to mo ve if y ou turn in y our sleep. 6. T o stop treatment at any time, r[...]

  • Page 8

    Viewing the tr eatment scr eens Depending on how the sy stem has been configured, you will see one of the f ollowing e xample screens (shown in the S T mode) once therapy has started: 9 H5i humidifier 9 H5i humidifier 9 ClimateLine or ClimateLine MAX heated air tube 9 Climate Control – A uto 9 H5i humidifier 9 ClimateLine or ClimateLine MAX heate[...]

  • Page 9

    T o toggle bet ween treatment screens 1 and 2, press from your H OME screen. 9 T reatment with device trigger (Timed) and cycle (Timed, Ti Max or Ti Min) breath indicators 9 T reatment with spont aneous trigger and cycled breaths Viewing the Info menu The Inf o menu has a series of screens showing y our sleep quality , sleep report and ser vice inf[...]

  • Page 10

    Cleaning and maintenance Ref er to your mask and humidifier user guides for detailed instructions regarding the care of these devices. Daily Remo ve the air t ubing b y pulling on the finger grips on the cuf f . Hang it in a clean, dr y place until next use. Notes: • Do not hang the air tubing in direct sunlight as it ma y harden ov er time and e[...]

  • Page 11

    SD card An SD card has been supplied to gather therapy data from your VP AP device and provide set tings updates from y our clinician. When instructed to do so, disconnect the VP AP de vice from the pow er outlet, remov e your SD card, insert it in the protective f older and send it to your clinician. Removing the car d 1. Push in the SD card to re[...]

  • Page 12

    Gl ob al l ea d er s i n sl ee p a nd r e sp ir a tor y me di c in e ww w.resmed.com VP AP ™ ST VP AP ™ S POSITIVE AIRW A Y PRESSURE DEVICE Welcome Guide English • Deutsch • Français • Italiano • Español • Português • Nederlands • Polski • T ürkçe 368698/2 20 1 3-0 1 S9 VP AP ST / S9 VP AP S WELCOME EUR1 Manufacturer: ResMe[...]