ResMed S8 Series II manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ResMed S8 Series II, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ResMed S8 Series II one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ResMed S8 Series II. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ResMed S8 Series II should contain:
- informations concerning technical data of ResMed S8 Series II
- name of the manufacturer and a year of construction of the ResMed S8 Series II item
- rules of operation, control and maintenance of the ResMed S8 Series II item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ResMed S8 Series II alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ResMed S8 Series II, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ResMed service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ResMed S8 Series II.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ResMed S8 Series II item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    S8 S eries II S8 A utoSet Spirit™ II S8 Au t o Sc o r e ™ I I POSITIVE AI RWA Y P RESSURE DEVIC ES User Guide English ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA ResMed (UK) Ltd (EU Authorized Representative) 96 Milton Park [...]

  • Page 2

    Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contraindications 1 Adv erse Ef f ects 1 P arts of the S8 S eries II system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Masks 2 Humidifiers 2 ResScan Data Card 2 Using the S8 S eries II . . . . . . . . . . . . . . .[...]

  • Page 3

    1 Introduction Introduction S8 AutoSet Spirit II The S8 A utoSet Spirit II self-adjusting sleep apnea system is indicated for the treatment of obstructive sleep apnoea (OSA) in adult patients. The S8 Au toSet Spirit II self- adjusting sleep apnoea syste m has two treatment modes: AutoSe t and fixed-pressure CPAP. The S8 AutoSet Spirit II system is [...]

  • Page 4

    2 Parts of the S8 Series II system Your S8 Series II device comprises: • S8 Series II de vice • P o wer cord • Carry bag • 2 m air tubing. Optional components include: • Integrated humidifi er • F ront cap • 3 m air tubing • DC-1 2 conv erter • ResMed T ubing W rap. Masks A list of masks (and their settings) compat ible with these[...]

  • Page 5

    3 Using the S8 Series II Using the S8 Series II Setting Up 1 Connect the power cord to the socket at the rear of the S8 Series II device. 2 Plug the other end of the power cord into the power outlet. 3 Connect one end o f the air tubing firmly onto the air ou tlet. 4 Connect the assembled mask system to the free end of air tubing. For information o[...]

  • Page 6

    4 How to Use the Control Panel The control panel of the S8 Series II includes an L CD screen which displays the menus and treatment screens as well as a keypad for navigating through the menus and delivering treatment. The S8 Series II keypad has the following keys: The keypad and LCD are equipped with backligh ts that come on when the device is po[...]

  • Page 7

    5 Using the S8 Series II 4 Press or until you see the setting that you require. 5 Press to ap ply. Using the Mask -fitting Feature You can use the S8 Series II mask-fitting featur e to help you fit your mask properly. This feature delivers air pressure for a three-mi n ute period, prior to starting treatment, during which you can check and adjust y[...]

  • Page 8

    6 4 To start treatment, press . 5 Fit your mask as described in the mask user instructions. ! WARNING A mask should not be used un less the S8 S eries II device is powered a nd operating properly. Stopping Treatment To stop treatment at any time, re move your mask and press . If your clinician has enabled SmartStart, si mply remove your mask and tr[...]

  • Page 9

    7 Changing the Settings on your S8 II Device The Detailed Menu Your clinician may have enabled a detailed menu on your S8 Series II device. The figure below shows the d etailed menu in each mo de. T o enter the detail ed menu from the sta ndby (RAMP or SETTLING) screen, press . Note: The AutoSet menu is available on the S8 AutoSet Spirit I I only. [...]

  • Page 10

    8 Messages on the S8 Series II LCD Your clinician may have set your S8 Series II device to remind you about important events, such as when to replace your mask , when to insert your Data Card (if your device is Data Card e nabled) and so on. The reminder message is displayed on the LCD and is visible if the device is not delivering therapy. The bac[...]

  • Page 11

    9 Cleaning and Maintenance 3 Remove the Data Card by gripping the end of the Data Card and pul ling it out. 4 Store the Data Card in its protective folder when not in use. 5 Return the card in its protective folder to your clinician using a postal envelope. Updating Settings on your S8 device If your clinician has provided a Data Card with new devi[...]

  • Page 12

    10 ! WARNING Beware of electric shock. Do not immerse the device or power cord in water. Always unplug the devi ce before cleaning and make sure i t is dry before reconnecting. ! CAUTION • Do not hang the air t ubing in direct sunlight as it ma y harden over time and eventually crac k. • Do not use bleac h, c hlori ne, alcohol, or aromatic-base[...]

  • Page 13

    11 Frequently Asked Questions ! CAUTION • Do not at tempt to open the S8 Se ries II case. There are no user serviceable par ts inside. • Inspection and repai r should only be performe d by an authorised agent. Under no circumstances sh ould you attempt to serv ice or repair the S8 Series II your self . Frequently Asked Questions How will it fee[...]

  • Page 14

    12 Please consult the medical services departme nt of your carrier if you intend to use your S8 Series II on an aircraft. The S8 Ser i es II complies with US FCC Part 15, Class B requirements. Note: Do not use your S8 Series II while the aircraft is taking off or landing. Can I use my S8 S eries II if mains ( AC) power is not availa ble? A DC-12 co[...]

  • Page 15

    13 T roubleshooting Excessiv e leak. Adjust posi tion of mask and headgear . Replace caps if missi ng from ports on mask. Air t ubing may not be c onnected properly . Connect firmly at both ends. Air t ubing may be kinked or punct ured. Straighten or replace. Displays er r or message: SYSTEM ERRxxxx Call Service! or Exxxx (wher e xxxx defines an er[...]

  • Page 16

    14 Technical Specifications . The manufacturer reserves the right to ch ange these specifications without notice. The follow ing messa ge is display ed on th e LCD af ter you try t o update settings or copy data to the D ata Card: Settings Invalid Remove Card The identification details on the Data Card do not match the identificati on details on yo[...]

  • Page 17

    15 General W arnings and Cautions Symbols which appear on the device At tention, consult accompany ing documents; Follow instructions fo r use; Drip proof; T ype CF equipment; Dangerous voltage; Class II equipment; Start/Stop; Manufacturer; Envir onmental infor mation WEEE 20 02/96/EC is a European Directive that requires the proper disposal of ele[...]

  • Page 18

    16 • If o xygen is used with this de vice , the oxy gen flow must be t urned of f when the device is not operating. If the ox ygen has been lef t on, turn of f the device, then w ait 30 minutes before t urning on the device again. Explanation: When the P AP device is not in operation and the oxygen flo w is lef t on, oxy gen delivered into the ai[...]

  • Page 19

    17 Limited W arranty Limited Warranty ResMed warrants that your ResMed product shall be free from defects in material and workmanship for the period specifie d below from the date of purchase by th e initial consumer. This warranty is not transferable. Not e: Some models are not avai lable in all regions. If the product fails under conditions of no[...]

  • Page 20

    18[...]

  • Page 21

    19 Limited W arranty[...]

  • Page 22

    20[...]