Renesas H8/3864 Series manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Renesas H8/3864 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Renesas H8/3864 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Renesas H8/3864 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Renesas H8/3864 Series should contain:
- informations concerning technical data of Renesas H8/3864 Series
- name of the manufacturer and a year of construction of the Renesas H8/3864 Series item
- rules of operation, control and maintenance of the Renesas H8/3864 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Renesas H8/3864 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Renesas H8/3864 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Renesas service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Renesas H8/3864 Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Renesas H8/3864 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    H8/3864 Series QFP-80A User System Interface Cable (HS3864ECH61H) for E6000 Emulator User’s Manual HS3864ECH61HE(D)[...]

  • Page 2

    Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document. Renesas bears no responsibility fo r problem s that may arise with third party’s rights, including int ellectual property[...]

  • Page 3

    i Preface Thank you for purchasing this user system interface cable (HS3864ECH61H) for the Renesas’s original mi crocomputer H8/3864 series and H8/ 3887 series. The HS3864ECH61H is a user system interface cab le that connects an H8/3864 series, H8/3887 series E6000 em ulator (HS3880EPI60H; hereinafte r referred to as the emulator) t o the IC sock[...]

  • Page 4

    ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station ......................................... 4 2.2 Connecti[...]

  • Page 5

    Section 1 Configuration 1 UTION CA Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80A package IC socket on the user system. Figure 1 shows the configuration of the HS3864E CH61H user system interface cable for the FP-80A package.[...]

  • Page 6

    User system IC socket Cable head Screws (M2 x 12 mm) with flat washers Screws (M2 x 8 mm) with flat washers Socket cover (for fastening cable head) To emulator station Cable body Figure 1 HS3864ECH61H User System Interface Cable 2[...]

  • Page 7

    3 Table 1 lists t he HS3864ECH61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS3864ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-80A package 4 Socket cover 1 For installing an FP-80A-packaged MCU 5 Screws (M2 x 12 mm) 4 For fas[...]

  • Page 8

    Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so w ill damage[...]

  • Page 9

    2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so w ill damage the user system and the emulator pro[...]

  • Page 10

    2.2.4 Fastening Cable Head 6 UTION CA 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a s[...]

  • Page 11

    Fasten the user system interface cable head to the IC socket fo r an FP-80A package on the user system with the four screws (M2 x 12 m m ; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between scre ws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to [...]

  • Page 12

    2.2.5 Connecting Cable Body to Cabl e Head Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8[...]

  • Page 13

    2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-80A package (IC149-080-017-B5: m anufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewh at different from those of the actual chip&ap[...]

  • Page 14

    2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Unit: mm Tolerance: –0.5 mm Figure 6 Dimensions for User System Interface Cable Head 10[...]

  • Page 15

    2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7. Cable head User system Unit: mm Tolerance: –0.5 mm IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co. Ltd.) Figure 7 Resulting Dimensio[...]

  • Page 16

    Section 3 Installing the MCU to the User System 12 UTION CA 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becom[...]

  • Page 17

    MCU Pin 1 IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2 x 8 mm) with flat washers Socket cover Figure 8 Installing MCU to User System 13[...]

  • Page 18

    14 Section 4 Verifying Operation 1. When using the H8/3864 series, H8/3887 series E6000 em ulator (HS3880EPI60H), turn on the emulator according to the procedures descri bed in the H8/3864 seri es, H8/3887 series E6000 Emulator User' s Manual (HS3880EPI60HE). 2. Verify the user system interface cable c onnections by accessing ports and checkin[...]

  • Page 19

    Figure 9 shows the system clock oscillator on the us er system interface cable and the subclock input specifications. 15 R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator Ω Ω 0.8 Vcc 55 ns max. 55 ns max. 0.8 Vcc 0.3 Vcc 0 V Vcc Vcc: User System Vcc (1.8 to 5.5 V) 0.3 Vcc Subclock input specifications Figure 9 System[...]

  • Page 20

    Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifi [...]