Renesas H8/3834 Series manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Renesas H8/3834 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Renesas H8/3834 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Renesas H8/3834 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Renesas H8/3834 Series should contain:
- informations concerning technical data of Renesas H8/3834 Series
- name of the manufacturer and a year of construction of the Renesas H8/3834 Series item
- rules of operation, control and maintenance of the Renesas H8/3834 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Renesas H8/3834 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Renesas H8/3834 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Renesas service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Renesas H8/3834 Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Renesas H8/3834 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    H8/3834 Series, H8/3814 Series, H8/3877 Series FP-100A User System Interface Cable (HS3834ECF61H) for E6000 Emulator User’s Manual Rev. 4.0 4/1/03 Renesas Technology Corp. HS3834ECF61HE(D)[...]

  • Page 2

    Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document. Renesas bears no responsibility fo r problem s that may arise with third party’s rights, including int ellectual property[...]

  • Page 3

    i Preface Thank you for purchasing this user system interface cable (HS3834ECF61H) for the Renesas’s original mi crocomputer H8/300L series. The HS3834ECF61H is a user system interface cab le that connects an H8/300L series E6000 emulator (HS3L08EPI60H; hereinafter referred to as the emul ator) to the IC socket for a FP-100A package for the H8/38[...]

  • Page 4

    ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station ......................................... 3 2.2 Connecti[...]

  • Page 5

    Section 1 Configuration CAUTION Use an IC149-KS-11113-0 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100A package IC socket on the user system. Figure 1 shows the configuration of the HS3834E CF61H user system interface cable for the FP-100A package. Figure 1 HS3834ECF61H User System Interface Cable 1[...]

  • Page 6

    2 Table 1 lis ts the HS3834EC F61H component s. Please m ake sure you have all of t hese component s when unpacking. Table 1 HS3834ECF61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP-100A package 4 Socket cover 1 For installing an FP-100A-packaged MCU 5 Screws (M2.5 x 11 mm) 2 For faste[...]

  • Page 7

    Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system a[...]

  • Page 8

    Figure 2 Connecting User System Int erface Cable to Emulator Station 4[...]

  • Page 9

    2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pi n 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the[...]

  • Page 10

    6 2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a scre[...]

  • Page 11

    Figure 3 Connecting User System Interface Cable to User System 7[...]

  • Page 12

    2.2.5 Fastening Cable Body Connect the cable body to the cable head. Figure 4 Fastening Cable Body 8[...]

  • Page 13

    2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-100A package (IC149-KS-11113-0: m anufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewh at different from those of the actual chip&a[...]

  • Page 14

    2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10[...]

  • Page 15

    2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11[...]

  • Page 16

    Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw[...]

  • Page 17

    13 Section 4 Verifying Operation 1. When using the H8/300L series E6000 emulat or (HS3L08EPI60H), turn on the emulat or according to the procedures described in th e H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). 2. Verify the user system interface cable c onnections by accessing ports and checking the bus states of the pins. If a[...]

  • Page 18

    Figure 9 shows the system clock oscillator on the us er system interface cable and the subclock input specifications. 14 R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator Ω Ω 0.8 Vcc 55 ns max. 55 ns max. 0.8 Vcc 0.3 Vcc 0 V Vcc Vcc: User System Vcc (3.0 V to 5.0 V) 0.3 Vcc Subclock input specifications Figure 9 Syst[...]

  • Page 19

    Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specific[...]