Renesas FP-64E manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Renesas FP-64E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Renesas FP-64E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Renesas FP-64E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Renesas FP-64E should contain:
- informations concerning technical data of Renesas FP-64E
- name of the manufacturer and a year of construction of the Renesas FP-64E item
- rules of operation, control and maintenance of the Renesas FP-64E item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Renesas FP-64E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Renesas FP-64E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Renesas service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Renesas FP-64E.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Renesas FP-64E item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    2003.12.19 H8/36014 Group, H8/36024 Group FP-64E User System Interface Cable for E6000 Emulator User’s Manual HS36014ECH61H Renesas Micro computer Development Environmen t System Rev.2. 00[...]

  • Page 2

    Cautions Keep safety first in your circ uit desi gns! 1. Renesas Technology Corp . puts the maximum e ffort int o making s emiconducto r product s better and more reliable, but the re is always the poss ibility that trouble may occ ur with them. Trouble with semi conductors may lead t o personal i njury, fire or propert y damage. Remember to give d[...]

  • Page 3

    I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user sy stem interface cable until y ou fully understa nd its mec ha ni s m. User Syst em Interface Cable: Throughout thi s document, the ter m &q[...]

  • Page 4

    II LIMITED WARRANTY Renesas warrants its user system interface cabl es to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will re pair or replace any user system interfac e cables dete rmined to be defective in material and/or workmanship. User s ystem interface cables are we[...]

  • Page 5

    III State Law: Some states do not allo w the exclusion or limitatio n of implied warranties or liabilit y for incidental o r consequential d amages, so t he ab o ve limitation or excl usion ma y not appl y to you. This warr ant y give s yo u spec if ic lega l rig hts, and you ma y have other rig hts wh ic h may va ry fro m state to state. The Warra[...]

  • Page 6

    IV SAFETY PAGE READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user sy stem interface cable until y ou fully understa nd its mec ha ni s m. DEFINITION OF SI GNAL WORDS This is the safet y alert symbol. It is used to al[...]

  • Page 7

    V W ARNING Observe the pr ecautions listed below. Failur e to do so will result in a FIRE HA ZARD and will damage the user system and the emula tor product or will result in PERSONAL INJURY. Th e USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product b y yourself for e lectric sho ck prevention and quality assurance. 2. Always [...]

  • Page 8

    i Preface Thank y ou for purchasi ng th is user s ys tem in terface cable (HS36014ECH61H) for the R enesas’s origin al microcom puter H8/36014 series. The HS36014ECH61H is a u ser sy stem interf ace cable that connects an H8/36014 s eries E6000 emu lator (HS3664EPI61H; herein after ref erred to as the em ulator) t o the IC s ocket for an FP-64E p[...]

  • Page 9

    ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connectin g User Sys tem Interface C able to Emu lator Station (H8/36014 Series) ............ 3 2.2 Connectin g User S[...]

  • Page 10

    1 Section 1 Configuration CAUTION Use an IC149-064- 075-B51 socket ( manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64E package IC socket on th e user system. Figu re 1 show s the config uration of the HS36014EC H61H user sy stem in terface cable for the FP-64E package. Figure 1 HS36014ECH61H Us er System I nterface Cable[...]

  • Page 11

    2 Table 1 lists t he HS36014ECH61H com ponents . Please mak e sure y ou have all of th ese compon ents when u npacking. Table 1 HS36014ECH61H Com ponents No. Component Quantity Remarks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP-64E package 4 Socket cover 1 For installing an FP-64E-packaged MCU 5 Screws (M2 x 12 m m) 4 For fastenin[...]

  • Page 12

    3 Section 2 Connection Procedures 2.1 Connectin g User System Interface Cable to Emulator S tation (H8/36014 Series) W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch[...]

  • Page 13

    4 Figure 2 Connecting User System Interface Cable to Em ulator Station[...]

  • Page 14

    5 2.2 Connectin g User System Interface Cable to Ex pansion I/O Board (H8/36024 Series) W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned. Failure to do so will result in a[...]

  • Page 15

    6 Cable body connector User system interface cable CTS screws (M3 x 6 mm) Expansion I/O board cable USER INTERFACE CABL E6000 EMULATO E6000 Figure 3 Connecting User System Interface Cable to Expansion I/O Board[...]

  • Page 16

    7 2.3 Connectin g User System Interface Cable to User S ystem W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will dama[...]

  • Page 17

    8 2.3.3 I nserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-64E package on the user sy stem w ith pin 1 on the user system interface cable head, and in sert the user system interface cable head into th e IC socket on the user sy stem, as show n in figure 4. 2.3.4 Fas tening Cable Head C[...]

  • Page 18

    9 Fasten the us er system interf ace cable head to the IC socket for an FP-64E package on th e user system with the four screws (M2 x 12 mm ; with four flat w ashers) provided. Each s crew should be tighten ed a little at a time, altern ating between s crews on opposin g corners. Take special care, such as m anually secu ring the IC socket soldered[...]

  • Page 19

    10 2.3.5 Fastening Cable B ody Connect the cable body t o the cable head. Figure 5 Fastening Cable Body[...]

  • Page 20

    11 2.4 Reco mm ended Dime nsions for User System Mount Pad Figure 6 show s the recomm ended dimens ions for the mou nt pad (footprin t) for the user system w ith an IC socket for an F P -64E pack age (IC149- 064-075-B51: m anufactured by YAMAIC HI ELECTRONICS C o., Ltd.). Note that the dim ensions in figu r e 6 are somewh at different from those of[...]

  • Page 21

    12 2.5 Dimensions f or User System Interface Cable H ead The dimens ions for the user sy stem interface cable h ead are shown in f igure 7. Figure 7 Dim ensions for User System Interface Cable Head[...]

  • Page 22

    13 2.6 Resulting Di mensions after Conn ecting User System Interface Cab le The resulting dim ensions, after connectin g the user system interface cable head to the u ser system , are show n in figure 8. Figure 8 Resulting Dim ensions after Connecting User System Interface Cable[...]

  • Page 23

    14 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.29 N•m or less. If the applied torque cannot be accurately measured, stop tightening when th e force required to t urn the screw become[...]

  • Page 24

    15 Figure 9 Installing M CU to User System[...]

  • Page 25

    16 Section 4 Verifying Operation 1. When u sing the H8/ 36014 series E6000 em ulator (HS3664EPI61H), tu rn on the em ulator according to th e procedures described in the H8/300H Series E6000 Emu lator User's Manual (HS300HEPI61HE). 2. Verify the user sy stem interf ace cable connections by accessing ports and ch ecking th e bus states of the p[...]

  • Page 26

    17 Figure 10 sh o ws the system clock oscillator o n the user system interface cable. Figure 10 System Clock Oscillator[...]

  • Page 27

    18 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned w ith pin 1 on the cable head before insertin g the cable head into the us er system IC sock et. 2. The dimens ions of th e recommen ded moun t pad for the user sy stem IC socket are diff erent from those of th e MCU. 3. This user sy stem interf ace cable [...]

  • Page 28

    19 6. The P1 short connector is used f or testing. Do not rem ove the inserted jumper pin. Figure 12 P1 Short Connector[...]

  • Page 29

    H8/36014 Group, H8/36024 Group FP-64E User System Interface Cable for E6000 Emulator User's Manual Publication Date: Rev.1.00, March 18, 2002 Rev.2.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. ?[...]

  • Page 30

    H8/3601 4 Grou p, H8/3 6024 Group FP -64E User Sy stem I nterface Cable for E 6000 Emulato r User’ s Manual REJ10B0091-0200H[...]