Regency P33-LP4 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Regency P33-LP4, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Regency P33-LP4 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Regency P33-LP4. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Regency P33-LP4 should contain:
- informations concerning technical data of Regency P33-LP4
- name of the manufacturer and a year of construction of the Regency P33-LP4 item
- rules of operation, control and maintenance of the Regency P33-LP4 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Regency P33-LP4 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Regency P33-LP4, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Regency service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Regency P33-LP4.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Regency P33-LP4 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-520a MODELS: P33-NG4 Natural Gas P33-LP4 Propane P33-4 Zero Clearance Direct V ent Gas Fireplace 03/05/08 Owners & Installation Manual W ARNING: If the information in these instructions are not followed exactly , a fi re or explosion may result causing[...]

  • Page 2

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. The P33-4 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The P33-4 has been approved [...]

  • Page 3

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS Full Screen Doors ....................................................... 35 Optional W all Thermostat .......................................... 37 Optional Remote Control ............................................ 37 Optional W all Switch ...........................[...]

  • Page 4

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 4 SAFETY LABEL This is a copy of the label that accompanies each P33-4 Zero Clearance Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review . The safety label is located on the front inside base of the unit, visible when the bottom louver is open. NOTE: Reg[...]

  • Page 5

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 5 REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chapte r 10 (2) Revise 10.8. 3 by adding the fo llowing addit ional requireme nts: (a) For all side wall hor izontally vente d gas fueled equipm ent installed in e very dwelling, building or structure used i n whole or in part for residential [...]

  • Page 6

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 6 INST ALLA TION IMPORT ANT MESSAGE SA VE THESE INSTRUCTIONS The P33-NG4 or P3 3-LP4 Direct V ent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine[...]

  • Page 7

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 7 DUCT SYSTEM OPTION kit #946-556 The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home. Up to two kits may be installed on the fi replace. Please Note: Only 1 H[...]

  • Page 8

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 8 COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below . Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal stu[...]

  • Page 9

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 9 INST ALLA TION 3) For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fi replace itself.) 4) The top of the unit must not be closer than 30" (762mm) to the cei[...]

  • Page 10

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 10 The T op Facing Support, the Side Nailing Strips and the 2 T op Standof fs must be correctly positioned and attached to the top before the unit is put into position. T op Standoff Assembly The top standoffs are shipped in a fl at position and must be pulled up and bent into the correct [...]

  • Page 11

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 11 EXTERIOR VENT TERMINA TION LOCA TIONS INST ALLA TION A= Clearance above grade, veranda, porch, deck , or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *(mi n. 12"/30cm) D= V [...]

  • Page 12

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 12 IMPORT ANT If using any Cabinet Mantels with Part # 510956, 510958, 510962, 510964 and 510834 the wall thimble must be secured fi rst and venting must be attached to unit before sliding into fi nal position. Also Rigid V ent venting cannot be used with any of the mantels noted above. S[...]

  • Page 13

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 13 T ermination Cap W all Thimble 2 pieces (10" (254mm) Outer Diameter) 2 ”x4 ”o r2 ”x6 ” (21mm x 102mm or 21mm x 152mm) 6-7/8" (175mm) dia. air intake 4" (102mm) dia. flue pipe with spring spacer Screws (4 per connection) Screws (3 per connection) INST ALLA TION PROC[...]

  • Page 14

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 14 Pipe Length V ertical T erminal Storm Collar Flashing Ceiling Firestop 24" Length Adj.Pipe Length 1 1" - 14-5/8” 90 Elbow o Horizontal T ermination Cap # 946-523/P W all Thimble Vinyl Siding Standoff (Optional) Rigid Pipe Adapter # 510-9[...]

  • Page 15

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 15 INST ALLA TION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™[...]

  • Page 16

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 16 Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™ American Metal Products ® Amerivent Direct Metal-Fab ® Sure Seal Security Secure V ent ® Attic Insulation Shield 12” 46DV A-IS - N/A from FPI N/A N/A 4DAIS12 N/A SV4RSA Attic Insu[...]

  • Page 17

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 17 • V ent must be supported at offsets. • Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994). RIGID PIPE VENTING ARRANGEMENT[...]

  • Page 18

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 18 The P33-4 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas. The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Na[...]

  • Page 19

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 19 RIGID PIPE VENTING ARRANGEMENTS Horizontal T erminations REGENCY ® DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45 o and one 90 o elbow (two 45 o elbows equal one 90 o elbow).[...]

  • Page 20

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 20 Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with Three (3) 90 o Elbows INST ALLA TION One 90 o elbow = T wo 45 o elbows. Option V H + H1 With these options, maximum total pipe length is 30 feet with minimum of 6 feet tot[...]

  • Page 21

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 21 Horizontal V enting with Three (3) 90 o Elbows V ertical V enting with T wo (2) 90 o Elbows V ertical V enting with T wo (2) 90 o Elbows INST ALLA TION For additional vertical venting with 2 x 90 o elbows, refer to "Rigid Pipe V enting Arrangements" Section. One 90 o elbow = T [...]

  • Page 22

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 22 INST ALLA TION V ertical V enting with Three (3) 90 o Elbows V ertical V enting with Three (3) 90 o Elbows Option H V H + H1 V + V1 A) 1' Max. 1' Min. 3' Max. 3' Min. B) 2' Max. 2' Min. 4' Max. 5' Min. C) 3' Max. 3' Min.' 5' Max[...]

  • Page 23

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 23 Flex Liner Exhaust Flue A maximum of two certified joiner kits may be used per length. #948-305 35 ft (1 1m) Air Intake Co-linear DV V ertical T ermination Cap # 946-529 Co-Linear Flex Adapter with Kit# 946-563 Outer Pipe with Kit# 946-563 Inn[...]

  • Page 24

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 24 VENTING ARRANGEMENTS - VERTICAL TERMINA TIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations. INST ALLA TION 8' (2.4m) Min. 30” (762mm) 30' (9.1[...]

  • Page 25

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 25 Riser V ent T ermination Min. 6-1/4"* (159mm) INST ALLA TION Diagram 3 UNIT INST ALLA TION WITH HORIZONT AL TERMINA TION Diagram 1 b) Horizontal runs of vent must be supported every three feet. W all straps are available for this purpose. 5) Mark the wall for a 10" x 10" s[...]

  • Page 26

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 26 INST ALLA TION GAS LINE INST ALLA TION The gas line is brought through the right side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve. The gas line connection may be made of rigid pipe, copper pipe or[...]

  • Page 27

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 27 GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve dur in g a ny pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kP a) . D i sconnect piping fr[...]

  • Page 28

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 28 INST ALLA TION Each Kit contains one LPG Conversion Kit and one DC Sparker Kit. LPG Conversion Kit Contains: Qty . Part # Description 1 904-163 Burner Orifi ce #54 1 918-590 Decal "Converted to LPG" 1 908-528 Red "LPG" label 1 904-529 5/32" Allen Key 1 910-037 L[...]

  • Page 29

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 29 INST ALLA TION W ARNING! Do not overtighten the screw . Recommended to grip the wrench by the short side. 7) T urn control knob to the “OFF” position. 8) Remove the black protection cap by hand from the high-low knob (Fig.1). 9) Insert a 5/32” or 4mm Allen wrench into the hexagonal[...]

  • Page 30

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 30 INST ALLA TION 4) Connect the DC spark generator wires to the SIT V alve with the screw , which is provided in the kit. 5) Locate the ground lug at the receptical box, left of the unit. 6) Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit. [...]

  • Page 31

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 31 Note: The logs must not be in the unit. 3) Insert the back brick panel by carefully slipping it between the back wall of the fi rebox and the rear log bracket. OPTIONAL BRICK PA N E L S 1) Undo the bottom 2 door latches and open and remove glass door . Remove logs. 2) Attach the 2 Rear [...]

  • Page 32

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 32 Diagram 1 Diagram 3 ST ANDARD FLUSH DOOR The standard fl ush door comes with a black frame. T o install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1. Be careful that the glass gasket does not roll up; there must be [...]

  • Page 33

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 33 OPTIONAL BA Y DOOR The Bay louvers MUST be used with the Bay glass option. The optional Bay door is an overlay on the fl ush front. The standard fl ush door and glass must remain on the unit. 1) Hook the top of the bay door over the fl ush door fl ange and swing the bottom against th[...]

  • Page 34

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 34 6) Open the bottom louver . Pull the Burner ON/OFF control box from inside the bottom of the fi replace and position the slots in the bracket over the 2 screws on the left side of the bottom louver . Push down to lock into place. T ighten the screws. Burner ON/OFF control box 2) Install[...]

  • Page 35

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 35 FULL SCREEN DOORS 1) Before beginning the installation, remove the Glass Door from the unit. Refer to the manual for instructions. 2) Slide the Bottom Faceplate Bracket into the bottom of the unit, secure it into the pins located on the inside of the fi re box. Once the bracket is in pl[...]

  • Page 36

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 36 6) Place the Bottom Frame near the hinges, and fl ip down the hinges from the Bottom Face Plate. Secure the hinges in place to the Bottom Frame, using 2x #8 Self T apping Phillips screws per hinge. NOTE: Should the fi nished wall protrude beyond the face of the unit, you can accommodat[...]

  • Page 37

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 37 Optional W ALL SWITCH 1) Run the supplied 15' of wire through the right or left side gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire T able. 2) Connect the wire to the[...]

  • Page 38

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 38 WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However , a 120V A.C. power supply is needed for the fan/blower operation. (Do not cut the gro[...]

  • Page 39

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 39 Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. INST ALLA TION For PROP ANE Units and Units Equipped with DC Spar[...]

  • Page 40

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 40 INST ALLING THE OPTIONAL F AN 120 V olt AC power is needed for the fan switch and blower . The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualifi ed electrician. The neutral (wider) slot of the polarized receptacle sho[...]

  • Page 41

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 41 OPERA TING INSTRUCTIONS COPY OF THE LIGHTING PLA TE INSTRUCTIONS Gas Inlet OFF Gas Inlet[...]

  • Page 42

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 42 AERA TION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air shutter for a blue fl ame or close for a yellower fl ame. The burner aeration is factory set but may need adjusting due to [...]

  • Page 43

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 43 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year . When cleaning the logs, use a soft clean paint brush as th[...]

  • Page 44

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 44 MAINTENANCE THERMOPILE/ THERMOCOUPLE 1) Open the bottom louvers. 2) Loosen the thermocouple or thermopile with a 7/16" wrench. 3) Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Disconnect thermopile by loosening 2 screws marked TP on the valve. 4) Drop th[...]

  • Page 45

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 45 REMOVING V AL VE 1) Shut off the gas supply . 2) Remove the louvers (and bay door if it is on). 3) Open the fl ush door and remove the door . 4) Remove the logs. 5) Remove the burner/grate assembly by removing the two Phillips head screws and then lift the burner assembly out. Diagram 1[...]

  • Page 46

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 46 P ARTS LIST MAIN ASSEMBL Y Part # Description Part # Description Part # Description 1) 948-247 Door Handle 2) * Thermodisc Bracket 7) 910-428 Duplex Receptacle 8) 910-429 Box - Receptacle 9) 910-430 Cover - Receptacle 10) 904-687 Clamp Connector 13) 948-045 #12 Jack Chain 14) 948-1 15 Do[...]

  • Page 47

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 47 P ARTS LIST[...]

  • Page 48

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 48 BURNER & LOG ASSEMBL Y Part Description 53) 430-055 Gasket - V alve Access Plate - NG/LP 54) 910-421 Pilot ON/OFF Extension Knob 55) 910-422 Flame HI/LOW Extension Knob 56) 910-190 Piezo Ignitor and Nut 433-574/P V alve Assy - Natural Gas 433-576/P V alve Assy - Propane 57) 910-478 S[...]

  • Page 49

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 49 P ARTS LIST FLUSH FRONT & LOUVERS Part # Description Part # Description 1 17) 904-196 Magnet - 1' round 131) 430-947 Flush Glass T rim (set) - Brushed Steel (Option) 430-918 Flush Louvers (set) - Gold/Black (Option) 430-922 Flush Louvers (set) - Black (Option) 430-923 Flush Louv[...]

  • Page 50

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 50 111 1 17 123 1 17 123 125 126 120 120 107 120 108 107 120 120 120 120 120 107 120 120 106 120 106 120 120 120 129 129 11 8 107 11 7 11 7 11 7 11 7 11 7 11 7 11 2 11 0 131 430-930 Bay Front Complete 106) 940-079/P Side Glass 107) 936-243 Glass Gasket 108) 940-078/P Center Glass 1 10) * Ba[...]

  • Page 51

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 51 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd. is pleased to extend this limited[...]

  • Page 52

    Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 52 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _____________[...]