Regency I3100L manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Regency I3100L, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Regency I3100L one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Regency I3100L. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Regency I3100L should contain:
- informations concerning technical data of Regency I3100L
- name of the manufacturer and a year of construction of the Regency I3100L item
- rules of operation, control and maintenance of the Regency I3100L item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Regency I3100L alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Regency I3100L, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Regency service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Regency I3100L.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Regency I3100L item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 908-332b MODELS: H2100 I3100L WOOD Fireplace Insert & Hearth Heater 03/06/08 Owners & Installation Manual T ested by: Installer : Please complete the details on the back cover and leave this manual with the homeowner . Homeowner: Please keep these instr[...]

  • Page 2

    Regency Wood Insert & Hearth Heater 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those [...]

  • Page 3

    Regency Wood Insert & Hearth Heater 3 REGENCY FIREPLACE INSERTS & HEARTH HEA TER T ABLE OF CONTENTS SAFETY LABEL Safety Label For I3100L ................................................ 4 Safety Label For H2100M.............................................. 5 INST ALLA TION Before Installing Y our Insert.....................................[...]

  • Page 4

    Regency Wood Insert & Hearth Heater 4 LISTED F ACTORY BUIL T FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U.S.A. MODEL: I3100L TESTED TO: ULC S628-M93 / UL 1482-1998 / ULC S627-00 / UL 737-2000 REPORT NO. 632-323500 (MAR.1994) DO NOT REMOVE THIS LABEL 106 COMPONENTS REQUIRED FOR INST ALLA TION: 6" (150mm) ST AINLESS STEEL LINER. OPTION[...]

  • Page 5

    Regency Wood Insert & Hearth Heater 5 SAFETY LABEL This is a copy of the label that accompanies each Regency Hearth Heater . We have printed a copy of the contents here for your review . 103 DO NOT REMOVE BRICKS OR MORT AR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONL Y . DO NOT USE GRATE OR ELEV A TE FIRE. BUILD WOOD FIRE DIRECTLY ON [...]

  • Page 6

    Regency Wood Insert & Hearth Heater 6 INST ALLA TION CHIMNEY SPECIFICA TIONS Before installing, check and clean your chimney system thoroughly . If in doubt about its condi- tion, seek professional advice. Y our Regency Insert is designed for installation into a masonry fi replace that is constructed in accordance with the requirements of &quo[...]

  • Page 7

    Regency Wood Insert & Hearth Heater 7 Clearance diagram for installations INST ALLA TION Side and T op facing is a maximum of 1.5" thick. Floor protection must non-combustible, insula- tive material with an R value of 1.1 or greater . * If the hearth extension is fl ush with the fl oor (F) it must extend 19.5" in front of the body f[...]

  • Page 8

    Regency Wood Insert & Hearth Heater 8 1) Positive Flue Connection with Cleanout FLUE CONNECT OR BRACKET Package contains: 3 brackets and 6 screws. These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the connection. The brackets are screwed into the top of the Insert in the pre-punched holes and then scre[...]

  • Page 9

    Regency Wood Insert & Hearth Heater 9 INST ALLA TION Diagram 1: H2100M and I3100L Faceplate Assembly A) H2100M and I3100L Insert 1) Slide the spring nuts (supplied) over the slots in the insert’s side convection panels (the spring nuts may need to be squeezed with a pair of pliers fi rst, to help them stay in position). 2) Screw the side fac[...]

  • Page 10

    Regency Wood Insert & Hearth Heater 10 Ground Fan Fan Ground Green Neutral Live White Fan Switch Manual/ Auto Switch Black Black High (Black) Low (Red) Black Fan Thermodisc (normally open) 120V AC 60 Hz Thermo Switch Sensor Thermo Switch Sensor INST ALLA TION F AN / BLOWER Blower/Fan Wiring Diagram 3) Slide the supports into the clips. The tens[...]

  • Page 11

    Regency Wood Insert & Hearth Heater 11 BRICK FLUE BAFFLE & SECONDAR Y AIR TUBE INST ALLA TION The fl ue baf fl e system located in the upper area of the fi rebox is removable to make cleaning your chimney system easier . The brick baf fl es must be installed prior to your fi rst fi re. Smoke spillage and draft problems may occur if th[...]

  • Page 12

    Regency Wood Insert & Hearth Heater 12 Pull Open Push Closed INST ALLA TION Hearth Heater (H2100M) Steel Baf fl e Place the insulation batt on top of the baf fl e. Make sure that this batt is laying fl at and does not obstruct the smoke from getting up the fl ue opening. This insulating batt may be wrapped in paper for handling purposes and[...]

  • Page 13

    Regency Wood Insert & Hearth Heater 13 automatic temperature sensor will engage the blower when the unit is at temperature and will shut off the blower once the fi re has gone out and the unit has cooled to below a useful heat output range. T o manually operate the fan system, push the fi rst switch to "Man" and second switch to eit[...]

  • Page 14

    Regency Wood Insert & Hearth Heater 14 6) Do not permit creosote or soot buildup in the chimney system. Check and clean chimney at regular intervals. 7) Y our Regency Insert can be very hot. Y ou may be seriously burned if you touch the insert while it is operating. W arn children of the burn hazard. 8) The insert consumes air while operating, [...]

  • Page 15

    Regency Wood Insert & Hearth Heater 15 I3100 MAIN ASSEMBL Y Part # Description 846-910 Door Assembly-Large Gold (I3100)-no glass 846-916 Door Assembly-Large Black (I3100)-no glass 3) 846-304 Glass - Replacement - (I3100) 4) 936-243 7/8" Adhesive T ape Gasket 5) 846-920 Glass Retainer Clips (set of 8) 6) * Screw 1/4-20 x 3/8" 7) 948-17[...]

  • Page 16

    Regency Wood Insert & Hearth Heater 16 P ARTS LIST I3100 F ACEPLA TES Part # Description Faceplate: I3100L 163-910 Faceplate & T rim Set - Regular 385) 163-165 Trim Right Regular 386) 163-160 Trim T op Regular 387) 163-161 Trim Left Regular 388) * Faceplate Side Regular 389) * Faceplate T op Regular 163-912 Faceplate & T rim Set - Overs[...]

  • Page 17

    Regency Wood Insert & Hearth Heater 17 H2100 MAIN ASSEMBL Y Part # Description Part # Description 1) 846-910 Door Assembly-Large Gold - no glass 846-916 Door Assembly-Large Black - no glass 3) 846-304 Glass - Replacement 4) 936-243 7/8" Adhesive T ape Gasket 5) 846-920 Glass Retainer Clips (set of 8) 6) * Screw 1/4-20 x 3/8" 7) 948-17[...]

  • Page 18

    Regency Wood Insert & Hearth Heater 18 P ARTS LIST I3100 & H2100 FIREBRICK Part # Description 70) 902-1 1 1 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) 802-104 Brick Partial: 1-1/4" x 4" x 9" 72) 802-146 Brick Partial: 1-1/4" x 1-3/4" x 9" 75) 802-139 Brick Partial: 1-1/4" x 4" x [...]

  • Page 19

    Regency Wood Insert & Hearth Heater 19 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to [...]

  • Page 20

    Printed in Canada Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________________________________________[...]