Regency E33-NG manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Regency E33-NG, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Regency E33-NG one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Regency E33-NG. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Regency E33-NG should contain:
- informations concerning technical data of Regency E33-NG
- name of the manufacturer and a year of construction of the Regency E33-NG item
- rules of operation, control and maintenance of the Regency E33-NG item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Regency E33-NG alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Regency E33-NG, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Regency service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Regency E33-NG.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Regency E33-NG item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC, Canada V4G 1H4 918-408 W ARNING: Improper installation, adjustment, alteration, service or main- tenance can cause injury , property damage, or loss of life. Refer to this manual. For assistance or additional informa- tion consult an authorized installer , service agency or t[...]

  • Page 2

    2 E33 FPI Direct V ent Gas Insert FPI GAS FIREPLACE INSERT TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Insert by FPI. The E33 Gas Insert has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The E33-NG and E33-LP have been approved by Warnock Hersey for both s[...]

  • Page 3

    3 E33 FPI Direct V ent Gas Insert T ABLE OF CONTENTS FPI GAS FIREPLACE INSERT OPERA TING INSTRUCTIONS First Fire ........................................................................ 18 Operating Instructions .......................................................... 18 Lighting Procedure .........................................................[...]

  • Page 4

    4 E33 FPI Direct V ent Gas Insert SAFETY LABEL This is a copy of the labels that accompany each E33 Gas Insert. We have printed a copy of the contents here for your review . The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened. Ensure that the safety label is attached to the unit. NOTE: FPI uni[...]

  • Page 5

    5 E33 FPI Direct V ent Gas Insert IMPORT ANT : SA VE THESE INSTRUCTIONS The FPI Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdic- tion to determine the need for a permit prior to starting the installation. NOTE: Failure t[...]

  • Page 6

    6 E33 FPI Direct V ent Gas Insert 14) Install optional Excalibur Surround. See page 15. 15) Install optional remote control or wall ther- mostat, pages 17. 16) Final check (page 18): Before leaving this unit with the customer , the installer must ensure that the appliance is fi ring correctly . This includes: a) Clocking the appliance to ensure th[...]

  • Page 7

    7 E33 FPI Direct V ent Gas Insert MINIMUM CLEARANCES T O COMBUSTIBLES From Unit Side W alls * A 8" (203 mm) Ceiling B 47" (1 194 mm) Min. Mantel Height C 15" (381 mm) Max. Mantel Depth D 3-1/2" (89 mm) Alcove Width E 76" (1930 mm) Alcove Depth F 36" (914 mm) Hearth Height G 1-1/4" (32 mm) Hearth Width H 45-1/2&quo[...]

  • Page 8

    8 E33 FPI Direct V ent Gas Insert VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney . The fl ue length must be a minimum length of 8 ' (2.44m) and a ma[...]

  • Page 9

    9 E33 FPI Direct V ent Gas Insert OPTIONAL BRICK P ANEL Optional Brick Panel Set: Part # Description Qty T op (brick) panel 1 Back (brick) panel 1 Left (brick) panel 1 Right (brick)panel 1 340-043 T op bracket 1 340-094 Bottom clips 2 51 1-031 Brick clips 2 Diagram 1 GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply pipin[...]

  • Page 10

    10 E33 FPI Direct V ent Gas Insert T op Bracket 5) Place the top bracket onto the top edge of the top panel (refer to Diagram 2). Diagram 2 6) Slide the top panel and bracket assembly carefully onto the baffl e plate ensuring the panel is centered. Make sure the tabs of the top bracket fi t into the baffl e openings (refer to Diagram 3). 7) Inse[...]

  • Page 11

    11 E33 FPI Direct V ent Gas Insert INST ALLA TION 5) Re-install the grate (reverse step 3). 6) Line up the pin holes (located at the bottom of log 03-23 ) to the pins of the rear log sup- port and position them into place. (refer to Diagram 3) Diagram 3 03-23 Locating Pins 03-23 03-17 03-21 Diagram 5 7) Align the bottom grooves of log 03-21 onto th[...]

  • Page 12

    12 E33 FPI Direct V ent Gas Insert INST ALLA TION Final Installation 03-19 E33 CONVERSION KIT FROM NG T O LPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty . Part # Description 1 910-018 SIT Conversion Kit-50% T urndown LPG 1 910-037 LPG (Pilot Orifi ce) 1 904-641 Burne[...]

  • Page 13

    13 E33 FPI Direct V ent Gas Insert Diagram 4 INST ALLA TION 9) Attach the trim to the faceplate by using the plated screws (refer to Diagram 4). Rear V iew: Faceplate Assembly Diagram 1 F ACEPLA TE & TRIM INST ALLA TION 1) Lay the faceplate panels fl at, face down on something soft so they don't scratch. 2) T ake the top faceplate and ali[...]

  • Page 14

    14 E33 FPI Direct V ent Gas Insert INST ALLA TION Diagram 5 11 ) Push the FPI logo plate into the two holes in the bottom left corner of the faceplate. The standard fl ush door comes with a black frame. T o install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, (Diagram 1 and 2). Be caref[...]

  • Page 15

    15 E33 FPI Direct V ent Gas Insert 1) Align the left side Faceplate T rim Bracket with the Firebox Flange and secure using 2 screws as shown in diagram 1. Repeat for right side. Faceplate T rim Bracket Firebox Flange IMPORT ANT NOTE: When using the Surround, the unit must be set 1" further into the fi replace than the standard face- plate ins[...]

  • Page 16

    16 E33 FPI Direct V ent Gas Insert INST ALLA TION 1) Remove the rivets from the surround by pulling off the hoseclamp (located at the backside of surround) with a screwdriver or plyer . Re-install the rivets by putting them through the holes on the sides of the sur- round. 3) Remove the handles by removing the nut and screw . Install the new handle[...]

  • Page 17

    17 E33 FPI Direct V ent Gas Insert WIRING DIAGRAM INST ALLA TION This heater does not require a 120V A.C. supply for operation. However , a 120V A.C. power sup- ply is needed for the fan/blower operation. W ARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock ha[...]

  • Page 18

    18 E33 FPI Direct V ent Gas Insert OPERA TING INSTRUCTIONS 2) T urn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape. 3) Turn gas control knob counterclockwise so indicator points to the "PILOT" position. Depress the gas control knob fully . Depress the ig[...]

  • Page 19

    19 E33 FPI Direct V ent Gas Insert OPERA TING INSTRUCTIONS COPY OF LIGHTING INSTRUCTION PLA TE AUT OMA TIC CONVECTION F AN OPERA TION The fan operates automatically . T urn the knob on the side of the faceplate to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperature. After the unit has been turned off and[...]

  • Page 20

    20 E33 FPI Direct V ent Gas Insert MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually . Recommended areas to inspect as follows: 1) Check the V enting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These com- ponents[...]

  • Page 21

    21 E33 FPI Direct V ent Gas Insert MAINTENANCE F AN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the plate on the fl oor of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place. Caution: Label all wires prior to discon- necting when servicing controls. Wiri[...]

  • Page 22

    22 E33 FPI Direct V ent Gas Insert MAINTENANCE 11 ) Disconnect the inlet gas line. 12) Unplug the black and red wires at the valve. Undo the 2 TP wires at the valve. 13) Remove the 17 screws on the valve tray . 14) T ake out the valve tray from the unit. 15) Scrape of f the old gasket from the fl oor of the fi rebox and from the valve access plat[...]

  • Page 23

    23 E33 FPI Direct V ent Gas Insert P ARTS LIST MAIN ASSEMBL Y Part # Description 1) 340-038 Fan Access Plate 2) 340-103 Gasket - Fan Access Plate 3) 320-517/P Fan Assembly 120 V 910-331/P Fan Motor 120 V 5) 910-750 Power Cord 910-752 Wire Harness (Faceplate) 910-692 Wire Fan to Power Cord 910-737 Wire V alve to Spill Switch 7) 910-142 Fan Auto On/O[...]

  • Page 24

    24 E33 FPI Direct V ent Gas Insert P ARTS LIST BURNER & LOG ASSEMBL Y Part # Description 52) 340-104 Gasket - V alve Tray 340-574/P V alve Assembly - NG 340-576/P V alve Assembly - LP 56) 910-190 Piezo Ignitor and Nut 57) 910-378 V alve - S.I.T . - Natural Gas 910-380 V alve - S.I.T . - Propane 59) * V alve Tray 910-034 Pilot Assy-3 Flame Conv [...]

  • Page 25

    25 E33 FPI Direct V ent Gas Insert 83 84 85 86 87 88 88 88 88 89 90 90 FULL SCREEN FRONT INST ALLA TION Part # Description P ARTS LIST 83) T op Frame 84) 340-910 Full Screen Door - Black 85) Full Screen Left Door 86) Full Screen Right Door 87) Bottom Frame 88) Screw #8 x 1/2 Self T apping 89) 910-199 Wire Clip Holder 90) 948-042 Hinge Spring[...]

  • Page 26

    26 E33 FPI Direct V ent Gas Insert P ARTS LIST F ACEPLA TES, TRIMS AND HEARTHS Part # Description Part # Description 340-918 Fa ceplates and T rim (Complete) with Black Tr i m 340-919 Oversized Faceplate 74) 904-569 Fan Speed Control Knob 91) * Faceplate Side - Right 92) * Faceplate - T op 93) * Faceplate Side - Left Assy 340-532 T rim Set Packaged[...]

  • Page 27

    27 E33 FPI Direct V ent Gas Insert NOTES[...]

  • Page 28

    28 E33 FPI Direct V ent Gas Insert NOTES[...]

  • Page 29

    29 E33 FPI Direct V ent Gas Insert NOTES[...]

  • Page 30

    30 E33 FPI Direct V ent Gas Insert[...]

  • Page 31

    31 E33 FPI Direct V ent Gas Insert W ARRANTY FPI Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the origi[...]

  • Page 32

    32 E33 FPI Direct V ent Gas Insert Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ________________________________________[...]