Redring 520M/520TS manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Redring 520M/520TS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Redring 520M/520TS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Redring 520M/520TS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Redring 520M/520TS should contain:
- informations concerning technical data of Redring 520M/520TS
- name of the manufacturer and a year of construction of the Redring 520M/520TS item
- rules of operation, control and maintenance of the Redring 520M/520TS item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Redring 520M/520TS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Redring 520M/520TS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Redring service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Redring 520M/520TS.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Redring 520M/520TS item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Manual and Ther mostatic Power Shower Units Installation instructions & User guide IMPORT ANT : This booklet should be given to the customer after installation and demonstration. WARNING: Under no cir cumstances should this unit be connected to the mains water supply . 520M/520TS[...]

  • Page 2

    Thank you for choosing a quality 'Redring' product manufactur ed in Peterborough, England. CONTENTS Page Information for the user Important Safety Instructions 2 How to use your 'Redring' power shower 2 How to maintain your 'Redring' power shower 4 What to do if things go wrong 4 Additional accessories 10 Information f[...]

  • Page 3

    a) b) c) Diagram 3 3 The limiter is factory set but can be adjusted to suit on site conditions. If the position of the limiter requir es adjustment please refer to the section in the commissioning procedur e (page 9). 8. T o override the stop position of the limiter , press the button on Knob 'B' and continue turning Knob 'B' an[...]

  • Page 4

    The spray head rotates through approximately 140 o IN ORDER TO MAINT AIN THE PERFORMANCE OF YOUR SHOWER YOU MUST CLEAN THE SHOWERHEAD. NOTE: After use it is normal for some water to drip from the shower head for a few moments. HOW TO MAINT AIN YOUR 'REDRING' POWER SHOWER All water contains particles of lime which build up in the showerhea[...]

  • Page 5

    Check for faulty potentiometer switch, (located under knob 'A' inside front cover). Switch should be open circuit when turned fully anti-clockwise. b) Pump operates when motor is switched off Blockage in filter causing obstruction in water supply . Check and clean (see page 10). c) W ater too hot Blockage in filter causing obstruction in [...]

  • Page 6

    unit ie. Mounted as shown in diagrams 5/6. Choose a flat piece of wall to avoid possibility of distorting the backplate thus making the front cover a poor fit. 3. Adjust the positions to get the most convenient arrangement taking the following into account : - a) The possible need to use the handset over the sink for hair washing etc. b) The shower[...]

  • Page 7

    1. Surrey Flange (T op entry cylinder flange) Fitting Instructions. The hot connection to the Shower unit can be taken directly fr om the hot cylinder using a Surrey Flange. Diagram 10 shows how this flange should be fitted. 2. Essex Flange (Side entry cylinder flange) Fitting Instructions. Alternatively , the hot connection to the Shower unit can [...]

  • Page 8

    9. With an isolating valve connected, flush the pipework through to r emove particles etc. before making the final connection to the shower . A blockage in the waterways (particularly the spray rings and filter) will prevent the shower unit working pr operly . 10. The shower unit should only be used with "Redring" recommended fittings. Di[...]

  • Page 9

    C) Electrical 1. The electrical installation must be in accordance with curr ent BS. 7671 (I.E.E. regulations). 2. The unit should be connected into a switched 3 amp double pole fused spur , with a minimum contact gap of 3mm in each pole. The switch must be fitted outside the bathroom. Alternatively , a double pole ceiling switch, with a pull cord [...]

  • Page 10

    Gently prise away the limiter from the fr ont cover and rotate to new position. Rotate clockwise for a cooler stop position and anti- clockwise for a warmer stop position. Ensure that the limiter is pressed firmly home. Re- assemble T emperature Control Knob 'B' over the drive on the mixer unit and fix into place with a screw . Check that[...]

  • Page 11

    ASSEMBL Y OF RISER RAIL, HANDSET AND SOAP DISH Removable insert in soap dish for ease of cleaning Locating Key Additional knock out fixing slot if requir ed Diagram 12 11[...]

  • Page 12

    We, GDA Applied Energy , guarantee that should this power shower prove to be defective by reason of faulty workmanship or material within 24 months (12 months outside the U.K.) of the date of purchase or commencement of hire purchase we will replace the defective parts FREE OF CHARGE on condition that: • The appliance has been correctly installed[...]