A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Raypak 850, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Raypak 850 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Raypak 850. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Raypak 850 should contain:
- informations concerning technical data of Raypak 850
- name of the manufacturer and a year of construction of the Raypak 850 item
- rules of operation, control and maintenance of the Raypak 850 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Raypak 850 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Raypak 850, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Raypak service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Raypak 850.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Raypak 850 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    up to 99% Efficiency! Can be vented with PVC 300 • 500 • 850 MBTU Models Ultra Low Emissions[...]

  • Page 2

    2 94% thermal efficiency! Up to 99% part load! X treme Outdoor Performance XFyre  Condensing Modulating Boiler - The Green Choice Raypak’ s new XFyre  is a natural extension of our successful XT herm  modulating vertical boiler line (1,1.5, 2 Million BTUH) . Raypak offers new features not found in other mod-con style boilers and combines[...]

  • Page 3

    3 1 2 3 4 5 8 7 6 9 10 14 11 14 15 4a 12 13 5 12a 1. W ater Inlet As low as 50°F entering. All copper and brass factory installed vertical plumbing connections . Vertical plumbing allows boilers to be installed side by side or in tight places if need be . Male NPT connections. 2. Water Outlet All copper and brass factory installed vertical plumb- [...]

  • Page 4

    4 6 1 2 3 4 5 1. Flue Outlet Category IV - PVC, CPVC and Stainless steel certified. T he XFyre ships PVC ready , no extras to purchase! 2. High V oltage W iring Box 120V AC main incoming power connections . Boiler pump wiring and DHW pump wiring. Alarm power out. 3. Gas Inlet T he XFyre will operate at 100% full rate with gas pres- sures as low as [...]

  • Page 5

    1-1/4 2-1/2 8-1/2 5 9/16” MOUNTING HOLES 4X H WA TER INLET H WA TER OUTLET 22 12-3/4 6-3/4 32 2-3/4 13 4-1/2 6-3/4 7 25-3/4 3/4” NPT PVC CONDENSA TE DRAIN CONNECTION G GAS 7/8” ELECTRICAL CONNECTIONS K FLUE CONNECTION T COMBUSTION AIR CONNECTION (OPTIONAL) LEFT VIEW FRONT RIGHT VIEW REAR TOP VIEW F E A 1° JACKET TOP SLOPE V TM MENU RESET SCR[...]

  • Page 6

    6 X tremely Easy to Wire 300 28 17 19 8 14 5 14 5 40 36 27 17 500 47 16 31 7 24 4 24 4 40 56 24 18 850 80 40 53 17 40 10 40 10 40 80 40 20 XFyre Model 20°F GPM ⌬ T 40°F 30°F Minimum Flow* Rates Of Flow And Pressure Drops TYPE W 300 1693 1128 846 677 564 484 423 376 339 500 2821 1881 1411 1128 940 806 705 627 564 850 4796 3197 2398 1918 1599 13[...]

  • Page 7

    7 Boiler Control and On-Board Diagnostic Center Raypak’ s XFyre comes equipped with a microprocessor control center that displays its information on a 2x20 character LCD display in plain English. All set-up and programming is done at this interface . Control monitors boiler system status including safeties , ignition faults and also stores up to [...]

  • Page 8

    HEA T EXCHANGER JACKET OTHER GAS TRAIN SAFETIES OPERA TING CONTROLS ASME Section IV , National Board Registered, 160 PSI • H Stamp   Heat Exchanger T ubes • 316L Stainless Steel   Stainless Steel • CSA Verified AB-1953 CA low lead compliant   Pressure Relief Valve • 60 PSI   (loose) • 125 PSI   • 30, 45, 75[...]