A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ranger RCI-2970DX-50, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ranger RCI-2970DX-50 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ranger RCI-2970DX-50. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ranger RCI-2970DX-50 should contain:
- informations concerning technical data of Ranger RCI-2970DX-50
- name of the manufacturer and a year of construction of the Ranger RCI-2970DX-50 item
- rules of operation, control and maintenance of the Ranger RCI-2970DX-50 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ranger RCI-2970DX-50 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ranger RCI-2970DX-50, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ranger service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ranger RCI-2970DX-50.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ranger RCI-2970DX-50 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    AM/FM/SSB/CW Dual Band Amateur Mobile Transceiver Owner's Manual RCI-2950 DX RCI-2970 DX -150 - 1 - Table of Contents PAGE Chapter 1 Specifications ....................................................... 2 Chapter 2 Introduction .......................................................... 3 Unpacking .............................................[...]

  • Page 2

    - 2 - Chapter 1 Specifications GENERAL Model RCI-2950DX RCI-2970DX-150 Frequency Range: 12 meter : 10 meter 24.8900 ~24.9900 MHz 28.0000 ~29.6999 MHz 24.8900 ~24.9900 MHz 28.0000 ~29.6999 MHz Tuning Steps 100 Hz, 1 KHz, 10 KHz, 100 KHz, 1 MHz 100 Hz, 1 KHz, 10 KHz, 100 KHz, 1 MHz Emission USB, LSB, CW, AM, FM USB, LSB, CW, AM, FM Frequency Control [...]

  • Page 3

    - 4 - Chapter 3 Installation The RCI-2950DX/2970DX-150 is easy to install. All necessary parts (less the antenna and coax cable) have been included to facilitate installation. Transceiver Mounting Choose a suitable location for the transceiver that will allow easy access to the front panel as well as proper air circulation to the back of the unit. [...]

  • Page 4

    - 6 - Operation (Continued) 5. SQUELCH CONTROL : This control is used to control or eliminate receiver background noise in the ab sence of an incoming signal. For maximum receiver sensitivity, it is necessary that the control be adjusted only to the point where the receiver background noise is eliminated. Turn fully counterclockwis e and then slowl[...]

  • Page 5

    - 8 - Operation (Continued) 20. LOCK BUTTON (LOCK) : Disables the Frequency Selector Control, UP/DOWN buttons on the front co ntrol panel and remote UP/DOWN buttons on the microphone. Pressing this switch again will re-enable the frequency selectors. 21. UP/DOWN SELECTOR : These buttons are used to increase or decrease the frequency digit above the[...]

  • Page 6

    - 10 - Operation (Continued) Microphone 1. PTT SWITCH: The Push-To-Talk (PTT) switch controls the transmit and receive function of the radio. Push to transmit and release to receive. 2. REMOTE UP/DOWN SWITCH: The digit on the frequency display above the SHF “cursor” can be stepped up or down by pushing either of these buttons. For best results,[...]

  • Page 7

    - 12 - Operation (Continued) Mode Selection To Select an operating mode, rotate the MODE selector, and place it in the desired operating mode position. RF Power Control This feature allows the adjustment of the RF output power continuously over the range of 1W through 25W. - 13 - Chapter 5 Programming Receive Scanning The receive scanning feature a[...]

  • Page 8

    - 14 - Programming (Continued) 4. Set the desired frequency you wish to store in memory. 5. Press the ENT button. 6. Repeat the procedure to program other memory channels. Memory Channel Scanning You can scan the 10 pre-programmed memory locations by following the procedure described below: 1. Press MAN button. 2. Press the MEM button. 3. Slowly tu[...]

  • Page 9

    - 16 - Frequency Scanning (Continued) Memory Scanning The RCI-2950DX/2970DX-150 has 10 non- volatile memory locations which can be programmed with any frequency within the operating range of the radio. The scan function of th e unit can scan the frequencies in the 10 memory locations. The first step in utilizing the memory scan function is programm[...]

  • Page 10

    - 18 - Memo - 19 - Ranger Communications Limited Warranty Ranger Communication, Inc. (Ranger) warrant s to the original purchaser only this product against defects in material or workmanship, as noted below. Effective December 1, 2001, the following Ranger Communications, Inc.'s products are covered by a two (2) year limited warranty: 1. Amate[...]

  • Page 11

    - 20 - 401 W. 35 th Street, Sui te B National Cit y, CA 91950 (800) 446-5778 • FAX (619) 426-3788 Email: rci@rangerusa.com http: //www.rangerusa.com PRINTED IN TAIWAN AT2950011I[...]