A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Quantum QTM300CA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Quantum QTM300CA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Quantum QTM300CA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Quantum QTM300CA should contain:
- informations concerning technical data of Quantum QTM300CA
- name of the manufacturer and a year of construction of the Quantum QTM300CA item
- rules of operation, control and maintenance of the Quantum QTM300CA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Quantum QTM300CA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Quantum QTM300CA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Quantum service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Quantum QTM300CA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Quantum QTM300CA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    QTM300CA USER'S GUIDE Cloning Adapter for the QT3xx family of QProx™ ICs The QTM300CA is a cloning adapter designed to interface between any QT3xx 8-pin sensor IC (QT300, QT310, QT320) and a PC or other host device. This adapter permits the designer to upload settings from a PC into the target chip or to read the settings inside a chip. The [...]

  • Page 2

    To begin using the board right away 1. Connect the QTM300CA to a PC using the serial cable (included). Make sure the serial port is not being used by any other application or driver. 2. Connect the QTM300CA to the target board’s 10-pin IDC cloning header; the stripe of the cable connects to the pin marked with a white square . 3. Run QT3View on t[...]

  • Page 3

    Figure 1 - Board Layout If a QT3xx chip has been auto-detected, this button will clone Setups data from the QTM300CA to the chip. The ‘PROG’ LED (see next section) indicates the programming result. The QTM300CA can store three sources of data, one for each part type. The correct source will be used to program the detected part. Program Button T[...]

  • Page 4

    Indicates the programming status of the target chip in Stand-alone mode. The PROG LED will light during the cloning process in Stand-alone mode. Afterwards the LED will flash on/off 3 times to indicate completion: Fast flashing: (0.1s between flashes) the clone process was a success. Slow flashing: (1s between flashes) the clone process failed. If [...]

  • Page 5

    Figure 2 - QT3View Screen Restores a config file saved by (File | Save). All three part selector configurations (tabs) will be restored by this action. Saves all three part selector configurations to disk in a single file, to a file name of your choice. Selects the desired PC serial port. Com1 is selected by default when the software is first start[...]

  • Page 6

    The status bar at the bottom shows the serial port and connection status. Possibilities are: Serial Port Status: - Off Line - COM1: 57600 N 8 1 - COM2: 57600 N 8 1 Connection Status: - Status: Clone connected - Status: Clone & QT300 connected - Status: Clone & QT310 connected - Status: Clone & QT320 connected - Status: No Clone Status B[...]

  • Page 7

    Cloning Directly to a Chip You can read and clone back information to a QT3xx chip directly from your PC without involving the onboard stand-alone memory of the QTM300CA. Here’s how.... Refer to the device data sheet and the QT3View help file for more information on Setup issues. Clone the Setups to the chip:  Upload Setups to the chip from th[...]

  • Page 8

    Clone the Setups to the Chip:  Push the PROG button on the board.  The PROG LED will light to indicate programming status.  The PROG LED will flash to indicate the programming result; see page 4. Step 2 Hook everything up:  Connect the QTM300CA’s cloning cable to the target PCB, or insert a QT3xx chip into the onboard socket.  Powe[...]

  • Page 9

    If the Synchronization input is used, a 10K resistor should be used to avoid problems with the cloning process; see Figure 4 below. QT310 Place the connector as close as possible to the chip. Placing the cloning connector far from the part will increase sensor load capacitance Cx and decrease sensitivity, as some of the cloning lines are also sense[...]

  • Page 10

    Figure 5 - QT320 Clone Connections VSS 8 S2A S1A 2 6 3 C S2B S1B 5 C SCK OUT2 7 OUT2 S2 OUT1 4 OUT1 1 VDD Vdd S1 SDO SDI GND Electrode 2 Electrode 1 l q 10 QTM300CA/R1.02 25.09.03[...]

  • Page 11

    Table 1 - Clone Cable Functional Pinout - Usage by Part N/C N/C N/C 10 SCK SCK SCK 9 Vcc 1 Vcc 1 Vcc 1 8 SDI SDI SDI / REQ 7 SDO SDO SDO 6 N/C N/C N/C 5 N/C N/C N/C 4 N/C N/C DRDY 3 GND GND GND 2 Vcc 1 Vcc 1 Vcc 1 1 QT320 QT310 QT300 Pin Note 1: Vcc is connected via a 1K pullup on QTM300CA board Table 2- Chip ZIF Socket Order Information www.logica[...]

  • Page 12

    l Q Copyright © 2003 QRG Ltd. All rights reserved. Patented and patents pending Corporate Headquarters 1 Mitchell Point Ensign Way, Hamble SO31 4RF Great Britain Tel: +44 (0)23 8056 5600 Fax: +44 (0)23 8045 3939 admin@qprox.com www.qprox.com North America 651 Holiday Drive Bldg. 5 / 300 Pittsburgh, PA 15220 USA Tel: 412-391-7367 Fax: 412-291-1015 [...]