A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Quadra-Fire QV-PIER, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Quadra-Fire QV-PIER one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Quadra-Fire QV-PIER. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Quadra-Fire QV-PIER should contain:
- informations concerning technical data of Quadra-Fire QV-PIER
- name of the manufacturer and a year of construction of the Quadra-Fire QV-PIER item
- rules of operation, control and maintenance of the Quadra-Fire QV-PIER item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Quadra-Fire QV-PIER alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Quadra-Fire QV-PIER, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Quadra-Fire service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Quadra-Fire QV-PIER.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Quadra-Fire QV-PIER item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Models: QV -Pier QV -ST Series: HV -IPI Owner ’ s Manual Installation and Operation DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instructions included. •• • DO NO DO NO DO NO DO NO DO NO T T T T T DISCARD DISCARD DISCARD DISCARD DISCAR[...]

  • Page 2

    2 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or component s MA Y BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be at[...]

  • Page 3

    3 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 T able of Content s Safety and W arning Information .................................................. 2 Service Parts List ......................................................................... 4 Approvals and Codes .................................................[...]

  • Page 4

    4 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Part number list on following page. 6 Log Assembly (NG , LP) Exploded Part s Diagram Service Parts List QV -Pier-HV -IPI Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ 7 8 10 11 12 7 9 13 5 2 1 3 4[...]

  • Page 5

    5 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 SERVICE PARTS LIST IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. IT E M COM MO N P A RT SERI A L # P A RT NUM B ER Bu rn er Or [...]

  • Page 6

    6 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 (NG , LP) Exploded Parts Diagram Service Parts QV -ST -HV -IPI Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ Part number list on following page. 5 Log Assembly 6 7 9 10 11 7 8 12 4 2 3 1[...]

  • Page 7

    7 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 SERVICE PARTS LIST IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. QV -ST -HV -IPI IT E M CO MM O N P A RT SERIA L # P A RT NUMBE[...]

  • Page 8

    8 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 (NG , LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ QV -PIER-HV -IPI QV -ST -HV -IPI Î Î IT E M DESCRI PTI O N SERI A L # P A RT NUM BER 1 ON / OFF R oc ker Sw it ch 060-51 1 2 O N / OFF W ir e Asse mbl [...]

  • Page 9

    9 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Appliance Certification The Quadra-Fire fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODELS: Q V- PIER-HV -IPI, QV -S T - H V -IPI LABORA TOR Y : Underwriters La[...]

  • Page 10

    10 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 2 Getting St arted Introducing the Quadra-Fire Gas Fireplaces Quadra-Fire direct vent gas fireplaces are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. The information contained in thi[...]

  • Page 11

    11 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 1. Diagram of the QV -PIER-HV -IPI 5-1/ 4 (133m m) 1/2 (13m m) 12 (306 mm) Ø 8 (205mm ) 42-5/8 (10 82mm) Ø 8 (205mm ) 12 (305mm ) EL ECTR ICAL ACCE SS GAS L IN E ACCE SS 34-3/4 (883m m) 4-1/ 16 (102m m) 4-1/2 (114mm) 4-3/4 (121mm ) 2-5/16 (58m m) 37- 7/16 (95[...]

  • Page 12

    12 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 3. Diagram of the QV -ST -HV -IPI 5-14 (133mm) 12 (306mm) 1/2 (13mm) (4) 46-5/8 (1 183mm) 42 (1067mm) 32-5/16 (821mm) 21-9/16 (548mm) 36-3/16 (919mm) 2-5/16 (58mm) 4-3/4 (121mm) 4-1/16 (102mm) 4-1/2 (114mm) ELECT RICAL ACCES S GAS LINE ACCES S 12 (305mm) 4-1/2 [...]

  • Page 13

    13 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 3 Inst alling the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance require- ments for locating a fireplace within a room. Figure 4A. Fireplace Dimensions and Locations Clearance Requirements The top, back, and sides of the fireplace[...]

  • Page 14

    14 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Sides or Ends .......... 3 6 .................... 9 1 4 Floor . .. ................................ 0 ....................... 0 Rear V ent ........................... 1/ 2 .................[...]

  • Page 15

    15 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Framing should be constructed of 2 X 4 lumber or heavier . Model A B C D E QV -PIER-HV -IPI 42-1/8 42-1/2 23 35-3/4 48 QV -ST -HV -IPI 47-5/8 42-1/2 23 35-3/4 48 Figure 5. Framing Dimensions NOTE: DIMENSIONS SHOWN IN INCHES Shows center of 10” x 12” vent framing h[...]

  • Page 16

    16 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 NOTE: PIPES OVERLAP 1-1/4 INCHES A T EACH JOINT . Figure 6. DVP-Series Direct V ent Component Specifications (5-inch inner pipe / 8-inch outer pipe) D V P 9 0 S T 12- 9/1 6 11 - 1 / 4 7-1 /4 1-1/4 T YP 1/2 TYP 8-9 /16 DVP36 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN.[...]

  • Page 17

    17 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 7. V ent System Components and T ermination Kit s Step 3. Inst alling the V ent System A. V ent System Approvals These models are approved to use DVP series direct vent pipe components and terminations (see Figures 6 and 7). Approved vent system components are [...]

  • Page 18

    18 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 8 NOTE: On vertical venting configurations you may want to install the flue re- strictor (385-128). See flue restrictor installation in- structions. Flue Restrictor Instructions 1. Locate the flue restrictor which is in the manual bag. Figure 9 2. Break the Flu[...]

  • Page 19

    19 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 NA TURAL GAS VENTING WITH ONE 90° ELBOW V (FT .) H (FT .) 90 0 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ [...]

  • Page 20

    20 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 15. V enting with T wo 90° Elbows H 1 H V V V 1 H NA TURAL GAS VENTING WITH TWO 90° ELBOWS V (FT .) H + H 1 (FT .) 90 0 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9&[...]

  • Page 21

    21 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 16. V enting with T wo 90° Elbows Figure 17. V enting with T wo 90° Elbows H 1 V H V H H 1 NA TURAL GAS VENTING WITH TWO 90° ELBOWS V (FT .) H + H 1 (FT .) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914m[...]

  • Page 22

    22 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 18. V enting with three 90° elbows H H 1 H 2 V H V H 1 V 1 NA TURAL GAS VENTING WITH THREE 90° ELBOWS V + V 1 (FT .) H + H 1 (FT .) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4&[...]

  • Page 23

    23 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 19. V enting with three 90° elbows V H H 1 V 1 V H H 1 V 1 NA TURAL GAS VENTING WITH THREE 90° ELBOWS V + V 1 (FT .) H + H 1 (FT .) 90 0 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3&apos[...]

  • Page 24

    24 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 1. Att ach the First V ent Component to the Starting Collars T o attach the first vent component to the st arting collars of the fireplace: • Slide the first vent section onto the unit and push in until they snap lock in position. • Rotate this section to the desi[...]

  • Page 25

    25 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 4. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes. NOTE: Model DVP-TRAP does not need an exterior firestop on an exterior combustible wall. The firestop is built into the cap. T o instal[...]

  • Page 26

    26 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 25 Hole & New Framing Members CEILING NEW FRAMING MEM BERS EXIST ING CEILING JOIST S CHIMNEY HOLE 10" ( 254 mm) 10" (254 mm) NOTE: There must be NO INSULA TION or other combustibles inside the framed firestop opening. ! C. V ent T ermination For H[...]

  • Page 27

    27 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. V ent T ermination Minimum Clearances A = 12 " ....................... clearances above grade, veran- da, porch, deck or balcony B = 12 " ....................... cleara[...]

  • Page 28

    28 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 For V ertical T erminations - T o locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint. • Make the outline of the roof hole around the centerpoint nail. • The[...]

  • Page 29

    29 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Step 4. Positioning, Leveling, and Securing the Fireplace • Place the fireplace into position. • Level the fireplace from side to side and from front to back. • Shim the fireplace with non-combustible material, such as sheet metal, as necessary . • Secure the [...]

  • Page 30

    30 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible in[...]

  • Page 31

    31 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENT AL FIREPLACE OPERA TION. For Intermittent Pilot Ignition Wiring Ap[...]

  • Page 32

    32 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Wall Switch Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W .G . minimum wire and connect it to the fireplace ON/OFF switch pigtails. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING[...]

  • Page 33

    33 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 QV-S T - HV-I PI TO P E DG E SI DE E D GE QV- PI ER-HV -IPI TO P E DG E SI DE E DG E 0” GAP 0” GAP Step 9. Finishing Figure 38 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above th[...]

  • Page 34

    34 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Inst alling the T rim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sea[...]

  • Page 35

    35 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Figure 45. Figure 46. S tart by applying the teco-sil (granulated glass) to the base pan (see Figure 46). Pile a thin layer and follow the pattern on the base pan (see Figure 47). Figure 47. The electric ember bed must be prepared before the logs are set up (see Figur[...]

  • Page 36

    36 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Turn on the electric ember lights and paint the glass to a darkness as desired (see Figure 50). Figure 50. Make sure to paint the glass from both sides (see Figure 5 1 ). Figure 51. The ember bed is now complete (see Figure 52). Figure 52. Placing the Ember Material E[...]

  • Page 37

    37 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Ember Light Replacement Bulb In the lower gas valve compartment you will find three ac- cess panels for the three light bulbs (see Figure 54). Figure 54. Using a 5/16” nut driver remove the two bolts (see Figure 55 ). Figure 55. Pull the access panel to expose the l[...]

  • Page 38

    38 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at t[...]

  • Page 39

    39 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 T roubleshooting 5 With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and t[...]

  • Page 40

    40 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Intellifire Ignition System - (continued) Sym pt om Possibl e C auses C orr ecti ve Act i on s c. M odu l e is n ot grou n ded. V er i fy t h at m odu le is secu r ely gr ou n ded t o met al c h assis of applian ce. V erify t h at w ire h arn ess is f i rm ly con n ec[...]

  • Page 41

    41 Quadra-Fire • QV -PIER, QV -ST Series: HV -IPI • 2005-901 Rev . G • 2/06 Lifet ime Warrant y Î LIMITED LIFETIME W ARRANTY The Hearth & Home T echnologies limited Lifetime Warranty guarantees that the following component s will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them[...]