PSB Speakers G5C 0250 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of PSB Speakers G5C 0250, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of PSB Speakers G5C 0250 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of PSB Speakers G5C 0250. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of PSB Speakers G5C 0250 should contain:
- informations concerning technical data of PSB Speakers G5C 0250
- name of the manufacturer and a year of construction of the PSB Speakers G5C 0250 item
- rules of operation, control and maintenance of the PSB Speakers G5C 0250 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of PSB Speakers G5C 0250 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of PSB Speakers G5C 0250, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the PSB Speakers service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of PSB Speakers G5C 0250.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the PSB Speakers G5C 0250 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 1/16 Cod. 710.062.01.00 – Rev .08 – 02.05.02 Cy clin g Refrigerated Comp ressed Air Dryers with “Zero-Loss” Drain Trap Operation & Maintenance M[...]

  • Page 2

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 2/16 Cod. 710.062.01.00 – Rev .08 – 02.05.02 1. 0 GENERAL 1.1 How to use thi s ma nual All features of t his m achine, includi ng inf orm ation on saf e[...]

  • Page 3

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 3/16 Cod. 710.062.01.00 – Rev .08 – 02.05.02 1.6 Use The use of a dryer is recomm ende d for ne ar ly al l com presse d ai r appli cati ons, but espe ci[...]

  • Page 4

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 4/16 Cod. 710.062.01.00 – Rev .08 – 02.05.02 3.0 SET-UP 3.1 Posit ioni ng The drye r should be located in an area with a fl at f loor and prot e cti on [...]

  • Page 5

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 5/16 Cod. 710.062.01.00 – Rev .08 – 02.05.02 3.5 Dryer Transpor tati on or Long-Term St orage • Close inlet and outl e t valves, switch of f the de vi[...]

  • Page 6

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 6/16 Cod. 710.062.01.00 – Rev .08 – 02.05.02[...]

  • Page 7

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 7/16 Cod. 710.062.01.00 – Rev .08 – 02.05.02 6. 0 CONTRO L PANEL O PERATIO N These dr ye r s are e qui ppe d with an electroni c control ler. Pleas e no[...]

  • Page 8

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 8/16 Cod. 710.062.01.00 – Rev .08 – 02.05.02 6.4 Digi tal Di splay M essage (NOT flashing) Descriptio n Numeric Valu e D ewp oin t T emp er at ur e “I[...]

  • Page 9

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 9/16 Cod. 710.062.01.00 – Rev .08 – 02.05.02 Fan doesn't start and/or stop. Fault y fan therm ostat or pressostat Low refrigerant char ge Low load [...]

  • Page 10

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 10/16 C o d. 710.062.01.00 – R e v .08 – 02.05.02 8. 0 ZERO- LOSS DRAI N TRAP 8.1 O peration • The Zero-l oss drai n is designed to remove conde nsate[...]

  • Page 11

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 11/16 C o d. 710.062.01.00 – R e v .08 – 02.05.02 9. 0 DIM ENSI ONAL DATA M ODEL G5C 50 THRU 100 M ODEL G5C 120 THRU 250 M ODEL G5C 18 THRU 30[...]

  • Page 12

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 12/16 C o d. 710.062.01.00 – R e v .08 – 02.05.02 10. 0 REFRI GERATI ON CI RCUIT DI AGRAM S 1 Com pre s so r 8 R ef r i ger an t Fi lt er / D ryer 2 C o[...]

  • Page 13

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 13/16 C o d. 710.062.01.00 – R e v .08 – 02.05.02 G5C 100 (115/ 1/60) Cod. 714. 001.01. 00 µ G5C 120 (115/ 1/60) Cod. 714. 003.03. 00[...]

  • Page 14

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 14/16 C o d. 710.062.01.00 – R e v .08 – 02.05.02 G5C 150 (230/ 1/60) Cod. 714. 003.01.00 – Rev. 05 –10.01.01 µ µ µ µ µµ µ ICE 200 ICE 250[...]

  • Page 15

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 15/16 C o d. 710.062.01.00 – R e v .08 – 02.05.02 G5C 200 - 250 ( 230/1/60) ELEC TRIC WIRING DIAG RA M - Cod. 714. 002.01.00 – Rev. 05 – 29. 04.02 G[...]

  • Page 16

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 16/16 C o d. 710.062.01.00 – R e v .08 – 02.05.02 G5C 250 (460/ 3/60) PO W ER W IRING DIAGRAM - Cod. 714.003. 02.00 – Rev. 03 – 02.05. 02 G5C 250 (4[...]

  • Page 17

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 17/16 C o d. 710.062.01.00 – R e v .08 – 02.05.02 G5C 250 (460/ 3/60) TERM INAL BLOCK DIAGRAM - Cod. 714.003. 02.00 – Rev. 03 – 02.05. 02 G5C 250 (4[...]

  • Page 18

    PSB IND USTRIES IN C. • General Air Di vision • 1202 West 12th St reet, Erie, P A. 16501 G5C Drye rs Phone : 814-45—3651 Fax : 814-454-3492 • www.PSBI N DUSTR IES.com • psb@genair.net 18/16 C o d. 710.062.01.00 – R e v .08 – 02.05.02 G5C 250 (460/ 3/60) PARTS LIST - Cod. 714. 003.02.00 – Rev. 03 – 02.05.02 12. 0 SYSTEM INSTALLATI [...]