Procom AL500HYLA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Procom AL500HYLA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Procom AL500HYLA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Procom AL500HYLA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Procom AL500HYLA should contain:
- informations concerning technical data of Procom AL500HYLA
- name of the manufacturer and a year of construction of the Procom AL500HYLA item
- rules of operation, control and maintenance of the Procom AL500HYLA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Procom AL500HYLA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Procom AL500HYLA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Procom service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Procom AL500HYLA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Procom AL500HYLA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OUTDOOR GAS FIREPLACE IMPORTANT: Read this owner's manual carefully and completely before trying to assemble, operate, or service this heater . FOR YOUR SAFETY : Do not store or use gasoline or other flammable vapors and liquids in the vici nity of this or any other appliance. WHA T T O DO IF YOU SMELL GAS:  Do not try to light any applianc[...]

  • Page 2

    2 AL058-01 SAFETY INFORMA TION PRODUCT IDENTIFICA TION 1. Check the heater completely and thoroughly fo r damage. DO NOT run a damaged heater . 2. DO NOT alter the heater or operate a heater that has been modified from its original condition. 3. Use only propane gas. 4. Use only vapor with drawal prop ane gas. If any question, contact your LP deale[...]

  • Page 3

    3 AL058-01 INST ALLA TION TOOLS REQUIRED: ● Philips screwdriver ● Wrench Check if you have the items listed below before installation. ● Logs: 10 ● 4 × 14 self-tapping screw: 5 ● M4 × 10 screw: 32 ● M5 × 1 0 s c r e w : 4 ● C o l u m n : 4 ● Log grate: 1 ● Fixing hoop: 1 ● Hex head screw: 2 ● Handle: 1 ● Screen: 4 Caution[...]

  • Page 4

    4 AL058-01 7. Attach the four columns to the burne r plate with M4 × 10 screws provided. Do not tighten at this time. (See FIG .7) INST ALLA TION INSTRUCTIONS Continued Fi g ure 7 -Column installation 5. Install log s 1,2,3,4,5 by inserting each log screw into holes of corresponding grate branch . Make sure e ach log is placed in proper sequence.([...]

  • Page 5

    5 AL058-01 8. Set the top p anel in place on the columns and secure with M4 × 10 screws provided. Do not tighten at this time. (See FIG .8) 12. From the outer side, use M5 × 10 screws to fasten the fixing hoop on the right and left support. Fasten the other side of the fixing hoop af ter the cylinder is in place. (See FIG .1 1) Note: The installe[...]

  • Page 6

    6 AL058-01 CONNECTING TO GAS SUPPL Y C o n t i n u e d FUEL REQUIREMENTS:  Connect reg ulator/hose with sta ndard 20-pound LP cylinder coupler .  Call the LP gas supplier to inspe ct the cylinder . Do not use a damaged LP gas cylinder .  Do not use LP gas without proper decompression.  Do not connect irregul ar LP gas supply with heater[...]

  • Page 7

    7 AL058-01 11. S piders and insects can nest a nd live in outd oor appliances, especially in the bu rners and orifice s. This will interrupt the normal flow of LP gas to the heater and can be a very dangerous situation. Inspect for insect infiltration of burner/orifice when one of the following occurs: A. The smell of gas along with predomin ating [...]

  • Page 8

    8 AL058-01 PARTS NOT UNDER WARRANTY: Contact authorized dealers of this product or Parts Central if they can't supply original replacement part(s) Call P RO-COM's Parts Department at 1-877-886-5989 for referral information. When calling PRO-COM, have ready  Model number of your heater  The replacement part number ACCESSORIES Purchas[...]

  • Page 9

    9 AL058-01 PARTS LIST HP500MA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 7 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 AB01001 Top Panel 1 2 AB29001 Mesh Screen 2 3 AB29002 Mesh Screen 2 4 AL002-01 Column 6 5 AL009-01 Burner Fixing Plate 6 [...]

  • Page 10

    10 AL058-01 ILLUSTRATED PARTS BREAKDOWN AL500HYLA[...]

  • Page 11

    11 AL058-01 PARTS LIST HP500MA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 7 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 NBY50-200A1 Burner 1 2 NDW-L600×4 Safety Pilot 1 3 AB31002 Safety Pilot Inlet Tube ASM 1 4 NV2020-1217 Control Valve 1 [...]

  • Page 12

    12 AL058-01 ILLUSTRATED PARTS BREAKDOWN AL500HYLA[...]

  • Page 13

    13 AL058-01 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 7 of this manual. LOGS LIST AL500HYLA KEY NO. PART NUMBER DESCRIPTION QTY. 1 AL057-01 Log 1 1 2 AL057-02 Log 2 1 3 AL057-03 Log 3 1 4 AL057-04 Log 4 1 5 AL057-05 Log 5 1 6 AL057-06 Log 6 1 7 AL057[...]

  • Page 14

    1 4 AL058-01 LOGS LIST AL500HYLA NANJING PRO-COM ELECTR IC APPLIANCE CO.,LTD. #6 CHUANGYE ROAD, HIGH NEW TECH. ZONE, NANJING, 210061, CHINA PRO-COM T o ll-F r ee number : 1-877-886-5989[...]