Pelco SW2 manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco SW2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco SW2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco SW2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco SW2 should contain:
- informations concerning technical data of Pelco SW2
- name of the manufacturer and a year of construction of the Pelco SW2 item
- rules of operation, control and maintenance of the Pelco SW2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco SW2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco SW2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco SW2.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco SW2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Spectra III ™ Series Spectra III ™ SE Series Dome Drive ® QUICK ST ART GUIDE C2472M-A (12/05)[...]

  • Page 2

    2 C2472M-A (12/05) SW1 SW2 SW3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 on on ON SW1-1 is set to the ON position. All other switches are set to the OFF position. Figure 1. Default Switch Settings WELCOME Thank you for purchasing Pelco’ s Spectra III ™ SE/Spectra III ™ Series dome system. This manual provides the information required to set up and in[...]

  • Page 3

    C2472M-A (12/05) 3 SW2–T ermination Setting When connecting more than one Spectra dome to a single controller , terminate the unit farthest from the controller . T ermination is only required for the last dome in the series. The dome drive is shipped from the factory in the unterminated (OFF) position. T o terminate the dome drive, set the SW2 sw[...]

  • Page 4

    4 C2472M-A (12/05) Figure 2. Dome Drive Installation SPECTRA SWITCH SETTING ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 1 OFF OFF OFF OFF OFF OFF OFF OFF 2O N OFF OFF OFF OFF OFF OFF OFF 3 OFF O N OFF OFF OFF OFF OFF OFF 4O N O N OFF OFF OFF OFF OFF OFF 5 OFF OFF O N OFF OFF OFF OFF OFF 6O N OFF O N OFF OFF OFF OFF OFF 7 OFF O N O N OFF[...]

  • Page 5

    C2472M-A (12/05) 5 SPECTRA SWITCH SETTING ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 1O N OFF OFF OFF OFF OFF OFF OFF 2 OFF O N OFF OFF OFF OFF OFF OFF 3O N O N OFF OFF OFF OFF OFF OFF 4 OFF OFF O N OFF OFF OFF OFF OFF 5O N OFF O N OFF OFF OFF OFF OFF 6 OFF O N O N OFF OFF OFF OFF OFF 7O N O NO N OFF OFF OFF OFF OFF 8 OFF OFF OFF O N O[...]

  • Page 6

    6 C2472M-A (12/05) SPECTRA SWITCH SETTING ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 9 9O N O N OFF OFF OFF O N O N OFF 100 O F F OFF O N OFF OFF O N O N OFF 101 O N O F F ON OFF OFF O N O N OFF 102 O F F O N ON OFF OFF O N O N OFF 103 O N ON ON O F F OFF O N O N OFF 104 O F F OFF OFF O N OFF O N O N OFF 105 O N O F F OFF O N OFF O N O[...]

  • Page 7

    C2472M-A (12/05) 7 T able B. D Protocol Receiver Address (Continued) SPECTRA SWITCH SETTING ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 197 O N O F F ON OFF OFF OFF O N O N 198 O F F O N ON OFF OFF OFF O N O N 199 O N ON ON O F F OFF OFF O N O N 200 O F F OFF OFF O N OFF OFF O N O N 201 O N O F F OFF O N OFF OFF O N O N 202 O F F O N OF[...]

  • Page 8

    W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East[...]