Pelco FR82011 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco FR82011, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco FR82011 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco FR82011. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco FR82011 should contain:
- informations concerning technical data of Pelco FR82011
- name of the manufacturer and a year of construction of the Pelco FR82011 item
- rules of operation, control and maintenance of the Pelco FR82011 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco FR82011 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco FR82011, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco FR82011.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco FR82011 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® INST ALLA TION F T82011/FR82011 Ethernet Media Converter One 10BASE-T/100BASE-TX Port and One 100BASE-FX Fiber Port C2653M (6/07)[...]

  • Page 2

    [...]

  • Page 3

    C2653M (6/0 7) 3 Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Product Overview . . . . . . . . . . . . . . . . .[...]

  • Page 4

    4 C2653M (6/07) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Inst all in accordance with the manufacturer’ s instructions. 8. Do not install ne[...]

  • Page 5

    C2653M (6/0 7) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO N[...]

  • Page 6

    6 C2653M (6/07) Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation. RADIO AND TELEVIS ION INTERFERENCE T[...]

  • Page 7

    C2653M (6/0 7) 7 Product Overview DESCRIPTION The F T82011/FR82011 Ethernet media co nverter co n ve r ts 10 B AS E -T / 100BASE-TX data to 100BASE-FX data and vice versa. Designed for point -to-point applica tions, the F T82011/F R 82011 me d ia c on v er t er provides one 10BASE-T/100BASE-TX port and one 100BASE-FX fiber port. The F T82011 and FR[...]

  • Page 8

    8 C2653M (6/07) • Compatible with ot her Ethernet equipment: – 10BASE-T/100BASE-TX compat ibility with all Pelco © and third-pa rty 10BASE-T/ 100BASE-TX Ethernet devices – Fiber optic compatibility with all Pelco Ethernet devices that support WDM • Environmentally hardened • Designed to meet NEMA TS 2 and Caltrans traff ic signal control[...]

  • Page 9

    C2653M (6/0 7) 9 MODELS The F T82011 and FR82011 modules consist of the following se ries of models: Multimode Models:* F T82011MSTR-1 Ethernet media converter , one 10 BASE-T/100BASE-T X port, one multimode ST fiber port, one fiber , fiber optic co mpatibity with FR82011MSTR-1 and other multimode ST Pelco Ethernet devices that support WD M FR82011[...]

  • Page 10

    10 C2653M (6/07) FRONT PANEL Figure 2 illustrates the front panel of the F T82011 and FR82011 modules. Figure 2. Front Panel of F T82011 and FR82011 Modules For detailed information about the front-panel LEDs, refer to the T roubleshooting section. ì RESET BUTTON (restarts the unit) î 100BASE-FX ST A TUS LED ï OPTIC F AUL T LED (opt ical signal [...]

  • Page 11

    C2653M (6/0 7) 11 REAR PANEL Figure 3 illustrates the rear pa nel of the F T82011 and FR82011 modules. Figure 3. Rear Panel of F T82011 and FR82011 Mo dules (SC Fiber Connector Shown) For additional informati on about rear -panel connections, refer to the Installation section. For detailed information about the RJ-45 LEDs, refer to the T roubleshoo[...]

  • Page 12

    12 C2653M (6/07) Installation PACKAGE CONTENTS The following it ems are supplied: 1 F T82011 or FR82011 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4 -40 x 0.250-inch Phillips pa n head screws wi[...]

  • Page 13

    C2653M (6/0 7) 13 Using the TX Mode switch, you can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the F T82011/FR82011 module to automatically negotiate with the device to which the port is connected for data rate and duplex modes of operation: 10 Mbps or 100[...]

  • Page 14

    14 C2653M (6/07) MOUNTING The F T82011/FR82011 module can be mounted into a ra ck or can be used as a stand-alone module. As a stand-alone module, the un it can be placed on a desktop or can be mounted to a wall. NOTE: As a matter of convenience, it is recommended that you set the modes of operation for the 10BASE-T/100-BASE-TX port—if required?[...]

  • Page 15

    C2653M (6/0 7) 15 Mounting the F T82011/FR82011 Module Using the Wall Clip NOTE: Before mounting the F T82011/FR82011 module to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for making the various rear-pa nel cable connections. T o attach the F T82011/FR82011 module to a wall usi ng the supplied wall [...]

  • Page 16

    16 C2653M (6/07) CONNECTIONS Connections to the F T82011/FR82011 module are made on the rear panel of the unit (refer to Figure 6). Figure 6. F T82011/FR82011 Module Connecti ons As illustrated in Figure 6, F T82011/FR82011 connections consist of the following: • Power connection NOTES: – A 12 VDC or 24 VA C power supply can be us ed to power t[...]

  • Page 17

    C2653M (6/0 7) 17 • Fiber connection NOTE: Fiber port A of the F T82011 module connects to fiber port B of the FR82011 module or of any other Pelco Ethernet sw itch that supports wavelength division multiplexing (WDM). Similarly , fiber port B of the FR82011 module connects to fiber port A of the F T82011 module or of any other Pelco Ether net sw[...]

  • Page 18

    18 C2653M (6/07) T roubleshooting LED indicators on the front and rear panels of the F T82011/FR82011 module allow you to monitor operational status: • LED indicators on the front panel allow you to monitor operating power , 100BASE-FX port status, and optic signal/l aser status. Refer to T able B fo r information about the front-panel indicators[...]

  • Page 19

    C2653M (6/0 7) 19 100BASE-FX Status LED ( ) (Continued) Red Ethernet link is down. NOTE: In addition to a red 100BASE-FX Status LED, the Optic Fault LED is green or flashing red and the left RJ-45 Port Status LED (Link/Activity) is not lit . A link-down detection c ondition exists due to any of the followi ng fault conditions: • Laser fault (Opti[...]

  • Page 20

    20 C2653M (6/07) Optic Fault LED ( ) (Continued) Red Ethernet link is down. NOTE: In addition to a red Optic Fault LED, the 100BASE-FX LED and the left RJ-45 Port Status LED (Link/Activity) LED are not lit. A link-down detection c ondition exists due to any of the followi ng fault conditions: • 100BASE-FX port does not transmit or receive optical[...]

  • Page 21

    C2653M (6/0 7) 21 Optic Fault LED ( ) (Continued) Flashing red Ethernet link is down. NOTE: In addition to a flashing red Optic Fault LED, the 100BASE-FX LED is red and the left RJ-45 Port Status LED (Link/Activity) LED is not lit. Laser has shut down due to either of the following fault conditions: • Module is operating in extreme environmental [...]

  • Page 22

    22 C2653M (6/07) T able C. T roubleshooting with Rea r-Panel Indicators Indicator Color Meaning Possible Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port St atus LED - Left (Link/Activity) Amber A 10BASE-T link is estab- lished. — If 10BASE-T operation is desired, no action is required. If 10BASE-T operation is not desired, refer to the Set[...]

  • Page 23

    C2653M (6/0 7) 23 RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit Ethernet link is down. A link-down det ection condition exists due to any of the following fault conditions: • 10BASE-T/100BASE-TX fault on local module (Optic Fault LED is green or blinking red and 100BASE-FX Status LED is red) or 10BASE-T/100B[...]

  • Page 24

    24 C2653M (6/07) RJ-45 10BASE-T/100BASE-TX Port Stat us LED - Right (Duplex/Co llision) Amber Port is set to 10BASE-T full-duplex mode. — If 10BASE-T full-duplex operation is desired, no action is required. If 10BASE-T full-duplex operation is not desired, refer to the Setting 10BASE-T/ 100BASE-TX Port Modes of Operation section in this manual fo[...]

  • Page 25

    C2653M (6/0 7) 25 RJ-45 10BASE-T/100BASE-TX Po rt Status LED - Right (D uplex/Collision) (Continued) Green Port is set to 100BASE-TX full-duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required. If 100BASE-TX full-duplex operation is not desired, refer to the Setting 10BASE-T/100BASE-TX Port Modes of Operation section[...]

  • Page 26

    26 C2653M (6/07) RJ-45 10BASE-T/100BASE-TX Po rt Status LED - Right (D uplex/Collision) (Continued) Not lit Por t is set to 10BASE-T half-duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired, no action is required. If 10BASE-T half-duplex operation is not desired, refer to the Setting 10BASE-T/ 100BASE-TX Po[...]

  • Page 27

    C2653M (6/0 7) 27 Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Full- duplex or half-duplex Address T able Size 1,024 MAC address ent ries with automatic learning and aging Quality of Service IEEE 802.1p pr[...]

  • Page 28

    28 C2653M (6/07) OPTICAL POWER BUDGET AND MAXI MUM TRANSMISSION DIST ANCE Model Number Wavelength (T ransmit/Receive)* Optical Power Budget Maximum T ransmission Distance T ransmitter End Receiver End Fiber Port A Fiber Port B Multimode (62.5/125 μm) F T82011MSTR-1 FR82011MSTR-1 1310/850 nm 850/1310 nm 26 dB † 2 km (1.2 mi) ‡ F T82011MSCR-1 FR[...]

  • Page 29

    C2653M (6/0 7) 29 Appendix. RJ-45 Connector Pinouts Figure 7 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 7. RJ-45 MDI/MDI-X Connector Pinouts T able D summarizes RJ-45 MDI/MDI-X connector pinouts. T able D. RJ-45 MDI/MDI-X Connector Pinouts Pin Number MDI (Normal Mode) MDI-X (Crossed Mode) 1R X + T X + 2R X - T X - 3 TX+ RX+ 4 Not used No[...]

  • Page 30

    30 C2653M (6/07) The materials used in the manufacture of this document and its components are compliant to t he requirements of Directive 2002/95/EC. This equipment contains electrica l or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the E ur opean Union rega rding the disposal of waste electrical and[...]

  • Page 31

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment. Exception s to this warranty are as noted below: • Five years on fiber o ptic products and TW3 000 Series unshield ed twisted pair tr an[...]

  • Page 32

    ® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Canada | Finland | France | Germany | Italy | Macau | The Netherlands | Russia | Singapore South Africa | Spain | Sweden | United Ara[...]