Pelco EPS5000-300 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco EPS5000-300, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco EPS5000-300 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco EPS5000-300. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco EPS5000-300 should contain:
- informations concerning technical data of Pelco EPS5000-300
- name of the manufacturer and a year of construction of the Pelco EPS5000-300 item
- rules of operation, control and maintenance of the Pelco EPS5000-300 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco EPS5000-300 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco EPS5000-300, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco EPS5000-300.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco EPS5000-300 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INSTALLATION For Endura Modules EPS5000-300 External Redundant Power Supply C1631M-B (9/06)[...]

  • Page 2

    [...]

  • Page 3

    C1631M-B (9/06) 3 Contents Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 4

    4 C1631M-B (9/06)[...]

  • Page 5

    C1631M-B (9/06) 5 Regulatory Notices This device co mplies with Pa rt 15 of the FCC Rules. Operat ion is subject to the following two conditions: (1) this device may n ot c ause harmful interference, and (2 ) this device must accept any inte rference received, including interference tha t may cause undesired operat ion. RADIO AND TELEVISION INTERFE[...]

  • Page 6

    6 C1631M-B (9/06) Before Y ou Begin Please familiarize yourself with the parts list before in stalling the unit. PARTS LIST Qty Description 1 EPS5000-3 00 2 USA standard powe r cord 2 European st andard power cor d 2 UK standard power cord 2 Over -molded G-power cables 4 Screws wi th washers, 10- 32 x 0.750- inch, Phill ips, pan head 1 Rail Kit 2R [...]

  • Page 7

    C1631M-B (9/06) 7 Figure 1. Package Components Figure 2. Support Rail Kit EPS5000-300 SUPPORT RAIL KIT RACK MOUNT SCREW WITH WASHER 10-32 X 0.750 4 EA. INSTALLATION MANUAL OVER-MOLDED G-POWER CABLES 2 EA. UK STANDARD POWER CORD (250 VAC) 2 EA. EUROPEAN STANDARD POWER CORD (230 VAC) 2 EA. USA STANDARD POWER CORD (110 VAC) 2 EA. SHIPPING BOX SHOWN AC[...]

  • Page 8

    8 C1631M-B (9/06) Description The EPS5000-30 0 external redund ant power supply , which is 1 rack unit (RU) high, has dual 30 0 W power supplies tha t slide into a tray . The external po wer supply ca n be mounted into a 19-i nch, EIA-sta ndard rack. The EPS5000-3 00 can be us ed in the f ollowing ways: • Provide redund ant power to two fully pop[...]

  • Page 9

    C1631M-B (9/06) 9 Installation MOUNTING AN EPS5000-300 The power su pply , which is 1 RU hi gh, can prov ide redundant power to one or two fully populated RK5000PS-5 U. T o mount the power supply , follow these steps and refe r to Figure 5. 1. Insert the EPS5000- 300 into the rack. 2. Secure the EPS50 00-300 to the rack with four of the supplied 10[...]

  • Page 10

    10 C1631M-B (9/06) ATTACHING RAILS TO AN EPS5000-300 The rails gi ve the EP S5000-300 more support for rack mo unting, esp ecially i n deeper racks . T o at tach the ra ils, follow th ese st eps and re fer to Figure 7. 1. Secure th e two brac kets to the ba ck of the E PS5000-300 with the four s upplied 6-32 x 0.375-inch screws. 2. Place the rails [...]

  • Page 11

    C1631M-B (9/06) 11 Figure 8. Connecting to an RK5000PS-5U OVER-MOLDED CABLE EPS5000-300 RK5000PS-5U RK5000PS-5U OVER-MOLDED CABLE POWER CORD POWER CORD[...]

  • Page 12

    12 C1631M-B (9/06) Service REPLACING A POWER SUPPLY Y o u can easily replace either of the two power supplies in the EPS5000- 300 with a replacemnet (EPSPWR-300). Y ou will know if th er e is a prob- lem with a power supply beca use the blue Pelco badge on the fron t panel will turn off . Before replacing a power supply , check t he fuse. It ca n b[...]

  • Page 13

    C1631M-B (9/06) 13 Specifications ELECTRICAL Input V olt age 100-240 V AC Output Voltage 12 VDC Power Consumption Operating Maximum (non-inclusive of components within the rack) 100 V AC 103 W , 352 BTU/H 115 V AC 104 W , 355 BTU/H 220 V AC 109 W , 372 BTU/H Fuse 4 amps MECHANICAL Rack Units 1 Construction Aluminum Finish Black ENVIRONMENT AL Ambie[...]

  • Page 14

    14 C1631M-B (9/06)[...]

  • Page 15

    PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, witho ut charge, any m erchandise pro ved defective in mat erial or workmanship for a period of one year after the date of sh ipment. Exceptions to this warranty a re as noted below: • Five years on FR/ F T/FS Series fiber optic products an d TW3000 Series unshi elded[...]

  • Page 16

    W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .p elco.c om ISO 9001 Australia | Canada | Finland | France | Italy | Russia | Singapore | Spain | Sweden | The Netherlands | United Arab Emirates | United Kingdom | Un[...]