Pelco EH8100 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco EH8100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco EH8100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco EH8100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco EH8100 should contain:
- informations concerning technical data of Pelco EH8100
- name of the manufacturer and a year of construction of the Pelco EH8100 item
- rules of operation, control and maintenance of the Pelco EH8100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco EH8100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco EH8100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco EH8100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco EH8100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® INSTALLATION/OPERATION C1407M-H (1/07) EH8100 Series Pressurized Camera Enclosure[...]

  • Page 2

    2 C1407M-H (1/07) Contents Important Safe ty Instruct ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 3

    C1407M-H (1/07) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed al l warnings. 4. Follow all instructions. 5. Refer all servicing to qualified se rvice pers onnel. Servici ng is requir ed when the apparatus has been damage d in any way, suc h as power - supply cord or plug is damaged , liquid has been[...]

  • Page 4

    4 C1407M-H (1/07) Description Enclosures in the EH81 00 Series are sealed and pr essurized. They will accept CCD came ras with fixed focal length or motorized z oom lenses. The enclosures are wired for len ses with preset capabilities . MODELS EH8104 4-inch diamet er , 17-inch le ngth, two 20-watt heate rs EH8106 6-inch diamet er , 20-inch le ngth,[...]

  • Page 5

    C1407M-H (1/07) 5 Figure 1. EH8100 Series Encl osure - Rear View Figure 2. EH8100 Series Enclosure - Wiring Diagram SCHRAEDER VALVE SPIRAL RETAINING SPRING RETAINING SPRING END PRESSURE RELIEF VALVE T-HANDLE GROUND STUD AC NEUT AC LINE THERMOSTA T HTR * HTR * PP ZOOM PP FOCUS PP COM PP +5V LENS COM ZOOM FOCUS IRIS NOTES: Consult the manual section [...]

  • Page 6

    6 C1407M-H (1/07) MATING CONNECTOR ASSEMBLY T o assemble the 16-pin mating connector , perform the following steps: 1. Discard the white plas tic sleeve that is included with the connector a ssembly . Threa d the cable through the compression nut/strain re lief and co nnector she ll. 2. Prepa re the cabli ng by doin g the follo wing: Control Cable [...]

  • Page 7

    C1407M-H (1/07) 7 RECHARGING THE ENCLOSURE Y ou may use your own chargi ng equipment or Pelco’ s EH80 00RKIT to recharge the enclosur e. If you are using yo ur own equipment, a dj ust the regulator for an ou tput pressure of 12 psi (83 kPa). If you are using th e EH8000RKIT , it uses a regulator wit h a fixed, nonadju stable output pressure of 12[...]

  • Page 8

    8 C1407M-H (1/07) Servicing DISASSEMBLY 1. Disconnect the powe r from the enclosure . 2. Remove th e mating conn ector fro m the rear of the en closure by turning th e outer ri ng counte rclockwise unt il a click is felt; th en pull the mating portion of the conn ector off. Y ou may elect to remove the enclosure from its mount, wh ich will make the[...]

  • Page 9

    C1407M-H (1/07) 9 Specifications Electrical Input V oltage 120 V AC (230 V AC optional) for heaters Power Require ments 40 watts (EH8 104) 80 watts (EH8 106) Connector 16-pin recept acle with jam nut Mating Conne ctor MS-type connec tor (supplie d) Maximum Cable Distan ces 120 V AC EH8104 EH8106 16 AWG (1.5 mm 2 ) 4,477 ft (1 365 m) 2,238 ft (6 82 [...]

  • Page 10

    10 C1407M-H (1/07) Environmental Ambient Oper ating T emperatu re -40° to 1 22°F (-40° to 50°C) (with he ater) Vibr ation 5 to 60 Hz with 0.082-in ch total travel (15 g’ s at 60 Hz). From 60 to 1,0 00 Hz, 5 g’ s rms with random vibration Altitude Sea level to equivale nt of 10,000 feet ( 3,048 m) Acoustic Noise Operates in 150 dB acoustic n[...]

  • Page 11

    PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without char ge, any merchandise proved defective in material or workmanship for a period of one year after the date of sh ipment. Exceptions to this warranty a re as noted below: • Five years on FR/ F T/FS Series fiber optic products and TW3000 Se ries unshielded twi[...]

  • Page 12

    ® W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.c om ISO 9001 Australia | Canada | Finland | France | Italy | Russia | Singapore | Spain | Sweden | The Netherlands | United Arab Emirates | United Kingdom | [...]