Pelco C2622M manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C2622M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C2622M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco C2622M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco C2622M should contain:
- informations concerning technical data of Pelco C2622M
- name of the manufacturer and a year of construction of the Pelco C2622M item
- rules of operation, control and maintenance of the Pelco C2622M item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C2622M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C2622M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C2622M.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C2622M item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® INST ALLA TION FX82051 Unmanaged Ethernet Switch Five 10BASE-T/100BASE-TX Ports and One 100BASE-FX Fiber Port C2622M (2/07)[...]

  • Page 2

    2 C2622M (2/07) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Product Overview . . . . . . . . . . . . . . . . . [...]

  • Page 3

    C2622M (2/0 7) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Inst all in accordance with the manufacturer’ s instructions. 8. Do not install n[...]

  • Page 4

    4 C2622M (2/07) The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO NO[...]

  • Page 5

    C2622M (2/0 7) 5 Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation. RADIO AND TELEVIS ION INTERFERENCE [...]

  • Page 6

    6 C2622M (2/07) Product Overview DESCRIPTION The FX82051 unmanaged Ethernet switch provid es five 10BASE-T/100BASE-TX ports and one 100BASE-FX fiber port for the trans port of bidirectional Ethernet data. T wo fi bers are required to transport bidirectional data over th e fiber port. Available in mult imode and single-mode versions, the FX82051 Eth[...]

  • Page 7

    C2622M (2/0 7) 7 • Designed to meet NEMA TS 2 and Caltrans traff ic signal control equipment standards for ambient operating temperature, mechanical shock and vibrati on, humidity with condensation, high-line/low-line voltage conditions, and transient voltage protection NOTE: Conformal coating is required for operati on in environments with relat[...]

  • Page 8

    8 C2622M (2/07) FRONT PANEL Figure 2 illustrates the front panel of the FX82051 module. Figure 2. Front Panel of FX82051 Module For detailed information about t he front-panel LEDs, refer to T roubleshooting on page 17. ì Reset Button: Restarts the unit î 100BASE-FX Status LED ï Optic Fault LED: Optical signal status/l aser status indicator ñ P[...]

  • Page 9

    C2622M (2/0 7) 9 REAR PANEL Figure 3 illustrates the rear panel of the FX82051 module. Figure 3. Rear Panel of FX82051 Modul e (SC Fiber Connector Shown) For additional information about r ear -panel connections, refer to Installation on page 10. For detailed information about the RJ-45 LEDs, refer to T roubleshooting on page 17. ì Rack Power/Alar[...]

  • Page 10

    10 C2622M (2/07) Installation PACKAGE CONTENTS The following it ems are supplied: 1 FX82051 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4 - 40 x 0.250-inch Phillips pa n head screws with lock wa [...]

  • Page 11

    C2622M (2/0 7) 11 Using the TX Mode switch for a parti cular port, y ou can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the FX82051 mo dule to automatically negotiate with the device to which the port is connected fo r data rate and duplex modes of operatio[...]

  • Page 12

    12 C2622M (2/07) Ta b l e A . TX Mode Switch Settings TX Mode Switch Position 10BASE-T/100BASE-TX Modes of Operation 0 Auto Neg/Dis FC: Enables autonegotiation between 10 Mbps and 100 Mbps and between half-duplex and full-duplex modes, disable s flow control ( default setting) 1 100 FD/Dis FC: Selects 100 Mbps fu ll-duplex, disables flow control 2 [...]

  • Page 13

    C2622M (2/0 7) 13 MOUNTING The FX82051 module can be mounted into a rack or c an be used as a stand-alone module. As a stand- alone module, the unit can be placed on a desktop or can be mounted to a wall. NOTE: As a matter of convenience, it is recommended that you set t he modes of operation for each 10BASE-T/100BASE-TX port—if r equ ired—befo[...]

  • Page 14

    14 C2622M (2/07) Mounting the FX82051 Module Using the W all Clip NOTE: Before mounting the FX82051 module to a wall, ens ure that there is adequate space at both ends for viewing the front-panel LEDs and for ma king the various rear- panel cable connections. T o attach the FX82051 module to a wall using the supplied wall clip, refer to Figure 5 an[...]

  • Page 15

    C2622M (2/0 7) 15 CONNECTIONS Connections to the FX82051 module are made on the rear panel of the modul e (refer to Figure 6). Figur e 6. FX82051 Module Connection s As illustrated in Figure 6, FX82051 c onnections consist of the following: • Power connection NOTES: – A 12 VDC or 24 VA C power supply can be us ed to power the module when used a[...]

  • Page 16

    16 C2622M (2/07) Figure 7. Fiber Port Connections in Point-to-Point Application[...]

  • Page 17

    C2622M (2/0 7) 17 T roubleshooting LED indicators on the front and rear panels of the FX82051 module allow you to monitor operational status: • LED indicators on the front panel (refer to Fi gure 2) allow you to moni tor operating power , 100BASE-FX port status, and optic signal/laser status. Refer to T able B for information about the front-pane[...]

  • Page 18

    18 C2622M (2/07) Optic Fault LED ( ) Green The optical signal is being received and laser is operating properly . — No action required. Red The optical signal is not being received. Remote module is not powered on. Check power connections. Replace power supply if necessary . Fiber optic cable is not connected. Check fiber optic connections. Fiber[...]

  • Page 19

    C2622M (2/0 7) 19 Ta b l e C . T roubleshooting with Rear -Panel Indicators Indicator Color Meaning Possi ble Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port St atus LED - Left (Link/Activity) Amber A 10BASE-T link is established. — If 10BASE-T operation is desired, no action is required. If 10BASE-T operation is not desired, refer to Sett[...]

  • Page 20

    20 C2622M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit A 10BASE-T or 100BASE-TX link cannot be established. A problem may exist with the cable: • Cable is not connected to the module or to the 10BASE-T/100BASE-TX compatible device. • Cable is defective. • Cable is not the proper cable type. • C[...]

  • Page 21

    C2622M (2/0 7) 21 RJ-45 10BASE-T/100BASE-TX Port St atus LED - Right (Duplex/Collision) Amber Port is set to 10BASE-T full- duplex mode. — If 10BASE-T full-duplex operation is desired, no action is required. If 10BASE-T full- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 10 for information. [...]

  • Page 22

    22 C2622M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LE D - Right (Duplex/Collision) (Continued) Green Port is set to 100BASE-TX full- duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required. If 100BASE-TX full- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 10 [...]

  • Page 23

    C2622M (2/0 7) 23 RJ-45 10BASE-T/100BASE-TX Port Status LE D - Right (Duplex/Collision) (Continued) Not lit Port is set to 10BASE-T half- duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired, no action is required. If 10BASE-T half- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port M[...]

  • Page 24

    24 C2622M (2/07) Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Half-duplex or full-duplex Address T able Size 1,024 MAC address ent ries with automatic learning and a[...]

  • Page 25

    C2622M (2/0 7) 25 OPTICAL POWER BUDGET , TRANSMISSION DIST ANCE, AND LASER CLASS 1 LIMIT Model Number Wavelength (T ransm it/Receive) Optical Power Budget Maximum T ransmission Distance Laser Class 1 Limit* Multimode (62.5/125 μm) FX82051MSTR-2 1310/1310 nm 26 dB † 6 km (3.7 mi) ‡ <15.6 mW FX82051MSCR-2 1310/1310 nm 26 dB † 6 km (3.7 mi) [...]

  • Page 26

    26 C2622M (2/07) Appendix. RJ-45 Connector Pinouts Figure 8 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 8. RJ-45 MDI/MDI-X Connector Pinouts T able D summarizes RJ-45 MDI/MDI-X connector pinouts. T able D. RJ-45 MDI/MDI-X Connector Pinouts Pin Number MDI (Normal Mode) MDI-X (Crossed Mode) 1R X + T X + 2R X - T X - 3 TX+ RX+ 4 Not used Not[...]

  • Page 27

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment. Exception s to this warranty are as noted below: • Five years on fiber o ptic products and TW3 000 Series unshield ed twisted pair tr an[...]

  • Page 28

    ® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Canada | Finland | France | Germany | Italy | Macau | The Netherlands | Russia | Singapore South Africa | Spain | Sweden | United Ara[...]