Pelco c2462m-e manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco c2462m-e, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco c2462m-e one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco c2462m-e. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco c2462m-e should contain:
- informations concerning technical data of Pelco c2462m-e
- name of the manufacturer and a year of construction of the Pelco c2462m-e item
- rules of operation, control and maintenance of the Pelco c2462m-e item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco c2462m-e alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco c2462m-e, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco c2462m-e.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco c2462m-e item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLA TION C2462M-E (3/09) 090 Series Camclosure ® Indoor Integrated Camera System Surface Mount/In-Ceiling[...]

  • Page 2

    2 C2462M-E (3/09) Contents Important Safety Instructi ons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Descripti[...]

  • Page 3

    C2462M-E (3/09) 3 List of Illustrations 1 Removing the Dome Bubble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 Ceiling/W all In stallation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3 Concrete Ceilin[...]

  • Page 4

    4 C2462M-E (3/09) Important Safety Instructions 1. Installation and servicing should be d one only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moist[...]

  • Page 5

    C2462M-E (3/0 9) 5 Description The ICS090 Series Camclosure ® integrated camera system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted or recessed to the surface of a ceiling or wall. Prior to the installation of your n ew system, thoroughly familiarize yourself with the information [...]

  • Page 6

    6 C2462M-E (3/09) Remove the Dome Bubble T urn the dome bubble counterclockwise and lift (refer to Figure 1 ). Place the bubble on a non abrasive surface. Figure 1. Removing the Dome Bubb le If the unit is supplied with a dome liner , remove the li n er before installing the unit. T o remove the liner , gently lift it from the unit. Place t he line[...]

  • Page 7

    C2462M-E (3/0 9) 7 Installation The installation methods for the ICS090 Series include the following options: • Mount to the surface of a ceiling or wall • Install in a suspended ceiling • Install in a fixed ceiling or wall • Mount to the surface of a 4S standard electrical bo x • Install in a 4S deep electrica l box SURFACE INSTALLATION:[...]

  • Page 8

    8 C2462M-E (3/09) 4. Use 6-32 toggle bolts (not supplied) to attach the surface mount ring and back box to the mounting surface (refer to Figure 2 ). Figure 3. Concrete Ceiling/W all Installation Figure 2. Ceiling/Wall Installati on NOTE: For a concrete ceiling or wall installation, use 8-32 mounting hardware (not supplied), ref er to Figure 3.[...]

  • Page 9

    C2462M-E (3/0 9) 9 IN-CEILING INSTALLATION: SUSPENDED CEILING 1. Remove the ceiling tile from the ceiling (refer to Figure 4 ). 2. Cut a 4-inch diameter h ole in the ceiling tile. 3. Remove the surface mount ring from the back box (refer to Figure 5 on page 10 ): a. Place your fingers on the circular marks loca ted on the s ides of the surface moun[...]

  • Page 10

    Figure 5. How to Remove Surfac e Mount Ring from Back Box 10 C2462M-E (3/09) AC operation only: If you are wiring more than one Camclosure to the same transformer , connect one side of the transformer to the red wire on all uni ts; connect the other side of the transformer to the black wire on all units. NOTE: Failure to connect all of the units in[...]

  • Page 11

    C2462M-E (3/0 9) 11 IN-CEILING INSTALLATION: FIXED CEILING OR WALL 1. Cut a 4-inch diameter h ole in the ceiling/wall (refer to Figure 6 on p age 11 ). 2. Remove the surface mount ring from the back box (refer to Figure 5 on page 10 ). a. Place your fingers on the circular marks loca ted on the s ides of the surface mount ring. b. Pinch the sides. [...]

  • Page 12

    12 C2462M-E (3/09) SURFACE INSTALLATION: 4S STANDARD ELECTRICAL BOX 1. Attach the adapter ring to the 4S box with tw o 8-32 x 1.00-inch screws (supplied; refer to Figure 7 ). 2. Connect the video cable and wires. BNC: Connect the BNC connector from the Camclosure to a mating BNC connector . T wisted pair: Connect the blue wire to Video +; c onnect [...]

  • Page 13

    C2462M-E (3/0 9) 13 IN-CEILING INSTALLATION: 4S DEEP ELECTRICAL BOX 1. Remove the surface mount ring from the back box (refer to Figure 8 ): a. Place your fingers on the circular marks loca ted on the s ides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 2. Attach the adapter ring to the [...]

  • Page 14

    14 C2462M-E (3/09) Camera Positioning Figure 9. Positioning the Camera Manually rotate and tilt the came ra module to position th e camera. Do not over-rot ate the module. WAR NI NG : E xcessively turning the module in one direct ion could result in damage to the wiring.    ì T ilt 140° (20° to 160°) î Pan 360° ï Rotation 360°[...]

  • Page 15

    C2462M-E (3/0 9) 15 Camera Adjustments SWITCH SETTINGS FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS Refer to the switch drawing. The switch is located n ext to the lens. Automatic backlight compensation (factory setting) is used under va ry ing lighting conditions (suc h as ou tdoors) or fixed lighting con ditions where there are no bright spots that [...]

  • Page 16

    16 C2462M-E (3/09) FOCUS ADJUSTMENT NOTE: Y o u will need a miniature Phillips or flat-tip screw driver to loosen and tighten the locking screw. T o adjust the fo cus: 1. Loosen the focus locking screw . 2. Position the inverted dome appro ximately 0.125 inch (3.175 mm) from the front of the lens. Make sure that the len s and the dome are centered [...]

  • Page 17

    C2462M-E (3/0 9) 17 V ERTICAL PHASE ADJUSTMENT (24 V ac Operation Only) When using more than one camera power supply, a brief vertical roll may occur on the monitor when a camera view is switched. T o elim inate vertica l roll, reverse the 24 V AC connections on one camera. If both cameras are connected to the same transformer , this should solve t[...]

  • Page 18

    18 C2462M-E (3/09) Install Liner and Bubble DOME LINER INSTALLATION If the unit is supplied with a dome liner , reinstall th e liner be fore installing the dome bubble (refer to Figure 13 ): 1. Align the studs located on the camera module with the clips on the liner . 2. Lightly pinch the sides of the liner , opposite fro m the clips, and place the[...]

  • Page 19

    C2462M-E (3/0 9) 19 DOME BUBBLE INSTALLATION T o install the d ome bubble (refer to Figure 14 ): 1. Select the bubble (clear or smoked). 2. Align the standoffs of the bubble with the slots of the back box. Figure 14. Installing the Dome Bubble 3. T urn the bubble clockwise until it locks in place.[...]

  • Page 20

    20 C2462M-E (3/09) Service Connector An optional 4-foot service/monitor cable, part numb er ICS090-SC, is available for on- site setup and adjustments. T o use the cable, simply plug one end of the cable directly into the service connector of the ICS090, and then connect the other end to any st andard BNC (VIDEO IN) connector on a monitor . T o ass[...]

  • Page 21

    C2462M-E (3/09) 21 Specifications ELECTRICAL Input V oltage* 12 VDC or 24 V AC (±10%), autosensing Power Consumption 3 W or less Video Connector BNC *24 V AC power is recommended when installing any Camclosure integrated camera system under fluorescent lighting conditions. GENERAL Pan/T ilt Adjustment Pan 360° T ilt 140° (20° to 160° range) Ro[...]

  • Page 22

    22 C2462M-E (3/09) REVISION HISTORY Manual # Date Comments C2462M 11/02 Original version. C2462M-A 1/03 Added Regulatory Noti ces for FCC Class B. C2462M-B 10/05 Revised switch-set ting descript ions for vari focal lens. Adde d WEEE statement. C2462M-C 1/06 Updated factory sw itch setting s for varifo cal lens per ECO 13164. Updated w iring informa[...]

  • Page 23

    The materials us ed in the manufactu re of this documen t and its component s are compliant to th e requirement s of Directive 20 02/95/EC. This equipment co ntains electr ical or electron ic components t hat must be rec ycled properly to comply with Dir ective 2002/96/EC of the European Union re garding the disp osal of waste electrical and elec t[...]

  • Page 24

    Pelco, Inc. W orldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el (800) 289-9100 Fax (800) 289-9150 International T el +1 (559) 292-1981 Fax +1 (559) 348-1120 www .pelco.com[...]