Pelco C2434M manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C2434M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C2434M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco C2434M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco C2434M should contain:
- informations concerning technical data of Pelco C2434M
- name of the manufacturer and a year of construction of the Pelco C2434M item
- rules of operation, control and maintenance of the Pelco C2434M item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C2434M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C2434M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C2434M.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C2434M item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CC5BCBW Series Heavy-Duty Spectra ® Back Box Installation Manual C2434M (7/01) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120 ®[...]

  • Page 2

    2 Pelco Manual C2434M (7/01) IMPOR T ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser ved. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X ,6 o[...]

  • Page 3

    Pelco Manual C2434M (7/01) 3 DESCRIPTION The Heavy-Duty Spectra is perfect for installations where structural integrity and vandalism are a prior ity . The system features hea vy-duty constr uction and tamper-resistant barrel ke y locks . The in-ceiling model has a reinforced brac ket mounting system for installation in a fixed ceiling. Pendant mod[...]

  • Page 4

    4 Pelco Manual C2434M (7/01) 00535 SPRING CLIP 8-32X.275 INCH SCREW 00537 00530 00531 00532 CEILIN G MOUNTING RING S 00533 AT TA C H S A F E T Y CHAIN HERE 00534 INST ALLA TION OF IN-CEILING MODEL STEP 1 - PREP ARE CEILING a. Locate the center point of the mount- ing location. Drill a hole in the ceiling using a 3/32-inch drill. b. Insert the compa[...]

  • Page 5

    Pelco Manual C2434M (7/01) 5 LABEL SW1 L A B E L S W 2 SW1 SW2 RS-422 TERMINA TION SWITCH ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 SW2 00538 GREEN T AB RED T AB 00539 BARREL KEY LOCK BALL STUD RECEIVER BALL STUD 00497 TRIM LEASH TO USE YOUR DOME, REFER TO THE OPERA TION AND PROGRAMMING MANUAL. +5 to +24 VDC NOT USED NOT USED TX- TX+ VIDEO IN CONTROLLE[...]

  • Page 6

    6 Pelco Manual C2434M (7/01) INST ALLA TION OF PENDANT MODELS STEP 1 - DISASSEMBLE BACK BOX a. Tu rn the thumbscre w and open the hinged door located inside the back box. 01082 01081 01080 b. Unscrew the three Phillips scre ws located under neath the hinged door . Remove the inside portion of the back box. c. Remov e the inside mounting plate by lo[...]

  • Page 7

    Pelco Manual C2434M (7/01) 7 STEP 3 - INST ALL THE BACK BOX 01079 01078 a. Secure the conduit fitting to the hole located on the inside base of the octagonal back box. b. Pull the cable and wiring for the system through the octagonal back box and conduit fitting. Mount the back bo x to the mounting surface , cor ner , or pole mount. c. Thread the c[...]

  • Page 8

    8 Pelco Manual C2434M (7/01) STEP 5 - INST ALL DOME DRIVE LABEL SW1 L A B E L S W 2 SW1 SW2 RS-422 TERMINA TION SWITCH ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 SW2 00538 a. Set the DIP switches f or SW1 and SW2 on the bottom of the dome drive for the appropriate receiver address. Refer to the labels on the dome drive or T ables C through E in the Appe[...]

  • Page 9

    Pelco Manual C2434M (7/01) 9 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Unit does not operate. The controller is not communicating with the Spectra unit. Fan does not operate. Ve r tical roll on monitor when switching between cameras. DOME 1 POWER DOME 2 POWER DOME 3 POWER Check to see if the red LED on the circuit board in the back box is lit[...]

  • Page 10

    10 Pelco Manual C2434M (7/01) APPENDIX Ta b le A. Video Coaxial Cable Requirements Cable T ype* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) * Minimum cable requirements: 75 ohms impedance. All-copper center conductor . 95% braided copper shield. Ta b le B. 24 V A C Wiring Distances The follo wing are the re[...]

  • Page 11

    Pelco Manual C2434M (7/01) 11 Ta b le D. Switch Settings f or SW2 – P-T ype Control NOTE: F or Coaxitron controls , SW2 is not used; set all s witches OFF . For D-type control systems , refer to T able E. Baud Rate Switch Setting SW2-6 SW2-7 SW2-8 2400 OFF OFF OFF 4800 ON OFF OFF 9600 OFF ON OFF Receiver Switch Setting Address SW2-1 SW2-2 SW2-3 S[...]

  • Page 12

    12 Pelco Manual C2434M (7/01) Ta b le E. Switch Settings for SW2 – D-T ype Control (continued) (Continued on next page) Receiver Switch Setting Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OFF ON ON OFF OFF 52 OFF OFF ON OFF ON ON OFF OFF 53 ON OFF ON OFF ON O[...]

  • Page 13

    Pelco Manual C2434M (7/01) 13 Ta b le E. Switch Settings for SW2 – D-T ype Control (continued) Receiver Switch Setting Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 161 ON OFF OFF OFF OFF ON OFF ON 162 OFF ON OFF OFF OFF ON OFF ON 163 ON ON OFF OFF OFF ON OFF ON 164 OFF OFF ON OFF OFF ON OFF ON 165 ON OFF ON OFF OFF ON OFF ON 166 OFF ON[...]

  • Page 14

    14 Pelco Manual C2434M (7/01) SPECIFICA TIONS MECHANICAL Construction Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic Cable Entry In-Ceiling: .75-inch (1.91 cm) conduit fitting Pendant: Through 1.5-inch (3.81 cm) NPT pendant mount Pan Movement: 360 ° continuous pan rotation Vertical Tilt: Unobstructed +2 ° to -92 ° Manua[...]

  • Page 15

    Pelco Manual C2434M (7/01) 15 GENERAL Environment In-Ceiling: Indoor only Pendant: Indoor/outdoor Operating Range In-Ceiling: 32 to 122 ° F (0 to 50 ° C) Pendant: (Assumes no wind chill factor; for detailed test conditions, contact Pelco) Maximum: 140 ° F (60 ° C) absolute maximum 122 ° F (50 ° C) sustained maximum Minimum -15 ° F (-9.4 ° C[...]

  • Page 16

    16 Pelco Manual C2434M (7/01) REVISION HISTOR Y Manual # Date Comments C2434M 7/01 Original version. P elco, the P elco logo, Camclosure , Esprit, Genex, Legacy , and Spectra are registered trademarks of P elco. © Copyright 2001, Pelc o. Endura and ExSite are trademarks of P elco. All rights reser v ed. PRODUCT WARRANTY AND RETURN INFORMA TION WAR[...]