Pelco C1666M-A (4/06) 3 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C1666M-A (4/06) 3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C1666M-A (4/06) 3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco C1666M-A (4/06) 3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco C1666M-A (4/06) 3 should contain:
- informations concerning technical data of Pelco C1666M-A (4/06) 3
- name of the manufacturer and a year of construction of the Pelco C1666M-A (4/06) 3 item
- rules of operation, control and maintenance of the Pelco C1666M-A (4/06) 3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C1666M-A (4/06) 3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C1666M-A (4/06) 3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C1666M-A (4/06) 3.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C1666M-A (4/06) 3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLA TION TW3001AR Active Receiver Single Channel for UTP T ransmission C1666M-A (4/06)[...]

  • Page 2

    [...]

  • Page 3

    C1666M-A (4/06) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install nea[...]

  • Page 4

    4 C1666M-A (4/06) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE Thi[...]

  • Page 5

    C1666M-A (4/06) 5 Description The TW3001AR is a single-channel active receiver that can receive live video over unshielded twisted pair (UTP) cable. The adaptive technology in the TW3001AR automatically adjusts the low , medium and high frequency components of the video signal allowing for the best possible video transmission. The adaptive technolo[...]

  • Page 6

    6 C1666M-A (4/06) PARTS OF THE RECEIVER Figure 1. TW3001AR Parts  Rubber Feet (4): For placing unit on a fl at surface, such as a desk or shelf.  Status LED: Lights red when there is no UTP video being received. Lights green when there is UTP video being received. Flashes amber when Coaxitron pan/tilt/zoom (PTZ) control commands are being re[...]

  • Page 7

    C1666M-A (4/06) 7 Installation Make sure all parts are present for the unit. 1 Universal power supply (Part #PS04-1502-0512G) 1 Wall clip 1 2-pin power connector 1 2-pin UTP connector MOUNTING The TW3001AR receiver is 3 rack units high and can be mounted into a fi ber rack, onto a wall using a fiber wall mount kit or into the supplied wall clip. [...]

  • Page 8

    8 C1666M-A (4/06) USING A WALL CLIP To attach the TW3001AR receiver to a wall using the supplied wall clip, refer to Figure 2 and do the following: 1. Attach the wall clip to a wall using two screws (not supplied). 2. Slide the receiver into the clip until the two holes on the bottom of the receiver align with the two holes on the lower fl ange of[...]

  • Page 9

    C1666M-A (4/06) 9 SETTING THE DIP SWITCHES Y ou can override the adaptive technology by manually adjusting switches 1-4 on the DIP Switch. The factory default switch positions are shown in Figure 3. Switches 1-4 are set to AUTO and Switch 5 is set to High Mode. Figure 3. Default Switch Positions If you want to transmit video over 4,000 feet (1,219 [...]

  • Page 10

    10 C1666M-A (4/06) APPLICATIONS Y ou can connect the TW3001AR active receiver to transmitters, such as the TW3001P passive trans- ceiver and the TW3001A T active transmitter , and to Pelco UTP cameras, such as the CC3710/CC3610 Series. Although you can connect these products using an unshielded twisted pair Cat3 and Cat5 cable, Cat5e and Cat6 are r[...]

  • Page 11

    C1666M-A (4/06) 11 Figure 4 shows a TW3001AR connected to a UTP camclosure. Figure 4. TW3001AR Connected to a UTP Camclosure + - CAMCLOSURE TW3001AR UTP MONITOR 12 VDC OR 24 VAC POWER SUPPLY BLUE WIRE = GRAY WIRE = POWER FROM RK5000PS-3U OR[...]

  • Page 12

    12 C1666M-A (4/06) Figure 5 shows a TW3001AR connected to a UTP fi xed camera. Figure 5. TW3001AR Connected to a UTP Fixed Camera + - TW3001AR FIXED CAMERA 8 PINS (4-/5+) MONITOR UTP PIN 5 + PIN 4 - 10 PINS (5-/6+) 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR[...]

  • Page 13

    C1666M-A (4/06) 13 Figure 6 shows a TW3001AR connected to a UTP Spectra dome for Coaxitron PTZ control. Figure 6. TW3001AR Connected to a Spectra Dome + - TW3001AR UTP VIDEO COAXITRON SPECTRA MONITOR MATRIX VC-UTP BOARD 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR[...]

  • Page 14

    14 C1666M-A (4/06) Figure 7 shows a TW3001AR connected to a TW3001P passive transceiver . The TW3001P then connects to a non-UTP fi xed camera. Figure 7. TW3001AR Connected to a Single Passive T ransceiver + - TW3001AR TW3001P UTP MONITOR DIRECT CONNECTION FIXED CAMERA 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR[...]

  • Page 15

    C1666M-A (4/06) 15 Figure 8 shows a TW3001AR connected to a TW3032P passive transceiver . Figure 8. TW3001AR Connected to a 32-Channel Passive T ransceiver + - TW3001AR TW3032P MONITOR UTP 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR[...]

  • Page 16

    16 C1666M-A (4/06) Figure 9 shows a TW3001AR connected to a TW3004P passive transceiver . The TW3004P then connects to a non-UTP fi xed camera. Figure 9. TW3001AR Connected to a 4-Channel Passive T ransceiver + - TW3001AR TW3004P 1 2 3 4 UTP MONITOR FIXED CAMERA 12 VDC OR 24 VAC POWER SUPPLY POWER FROM RK5000PS-3U OR[...]

  • Page 17

    C1666M-A (4/06) 17 Specifications ELECTRICAL Input Voltage 12 VDC or 24 VAC, 50-60Hz Power Consumption 2.5 watts Wire T ype Unshielded T wisted Pair (24 AWG maximum) Wire Category Cat3 or better DC Loop Resistance 52 ohms per 1,000 feet Differential Capacitance 19pF/ft max T ransient Immunity 300 W peak pulse power (8/20 US) Insertion Loss 72 dB o[...]

  • Page 18

    18 C1666M-A (4/06)[...]

  • Page 19

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FR/FT/FS Series fiber optic products and TW3000 Series unshielded twisted p[...]

  • Page 20

    Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East[...]