Pelco C1662M-A manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C1662M-A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C1662M-A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco C1662M-A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco C1662M-A should contain:
- informations concerning technical data of Pelco C1662M-A
- name of the manufacturer and a year of construction of the Pelco C1662M-A item
- rules of operation, control and maintenance of the Pelco C1662M-A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C1662M-A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C1662M-A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C1662M-A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C1662M-A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLA TION TW3000P Series Passive Multi-Channel V ideo T ransceivers C1662M-A (1/06)[...]

  • Page 2

    2 C1662M-A (1/06) Description The TW3000 Series multi-channel video transceivers can transmit multiple video signals over unshielded twisted pair (UTP) cable. The receivers are passive and require no power . The transceivers are available with 8, 16, or 32 channels and can be mounted into an industry standard 19-inch (48.26 cm) wide equipment rack.[...]

  • Page 3

    C1662M-A (1/06) 3 BACK VIEW Figure 1. Back View of TW3008P , TW3016P , TW3032P  Rack Ears: Allow mounting into an industry standard 19-inch wide equipment rack.  Thumbscrews: Allow back panels to be removed.  Panel with Connectors: The TW3008P and TW3016P have one blank panel.  BNC Connectors: The TW3008P , TW3016P , and TW3032P have 8,[...]

  • Page 4

    4 C1662M-A (1/06) Installation Make sure all parts are present for the units. TW3008P 4 Rack mount screws, 10-32 x 0.750-inch, Phillips, pan head (U.S.) 4 Rack mount screws, M6 x 1, 20 mm 4W ashers 2 Screw T erminal Connectors TW3016P 4 Rack mount screws, 10-32 x 0.750-inch, Phillips, pan head (U.S.) 4 Rack mount screws, M6 x 1, 20 mm 4W ashers 4 S[...]

  • Page 5

    C1662M-A (1/06) 5 MOUNTING The TW3008P , TW3016P , and TW3032P transceivers are 1 RU (1.75”) high and are supplied with the necessary parts for mounting into an industry standard 19-inch (48.26 cm) wide equipment rack. The units can also be placed on a fl at surface, such as a shelf. Figure 2. Rack Mounting[...]

  • Page 6

    6 C1662M-A (1/06) APPLICATIONS Figures 3-6 show how to use the transceivers in various applications. Always connect + to + and - to - . The TW3032P is used as an example in Figures 3-6. T able A shows the distance in feet with coaxitron or video only when using a particular type of Cat cable. T able B shows the maximum allowable wire gauge for sing[...]

  • Page 7

    C1662M-A (1/06) 7 Figure 4. Connecting a UTP Camera to a UTP Receiver NOTE: UTP cameras have a 10-pin RJ-45 connector. Standard RJ-45 connectors have 8 pins. Figure 5. UTP Camclosure to UTP Receiver 12 3 45 678 9 1 0 1 1 1 2 1 3 1 4 1 5 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 TW3032P UTP VIDEO MONITOR + - + - 10 PINS (5-/6+) PIN 5 + PIN [...]

  • Page 8

    8 C1662M-A (1/06) Figure 6. Coaxitron PTZ Control 12 3 45 678 9 1 0 1 1 1 2 1 3 1 4 1 5 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 TW3032P UTP VIDEO MONITOR SPECTRA COAXITRON + - + - VC-UTP BOARD MATRIX[...]

  • Page 9

    C1662M-A (1/06) 9 Service REPLACING A BACK PANEL Y ou can replace a blank back panel or a back panel with connectors easily . Figure 7 shows a blank panel being removed after the two thumbscrews are loosened. The panels with connectors can be removed the same way. Figure 7. Back Panel Replacement[...]

  • Page 10

    10 C1662M-A (1/06) Specifications ELECTRICAL Power Source No power required Wire T ype Unshielded twisted pair (24 AWG maximum) Wire Category Cat3 or better Wire Impedance 100 ohms +/ - 20% Wire Distance 750 feet maximum DC Loop Resistance 52 ohms per 1,000 feet Differential Capacitance 19pF/ft max T ransient Immunity 300 W peak pulse power (8/20 [...]

  • Page 11

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex ® Series p[...]

  • Page 12

    Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East[...]