Pelco C1306M manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C1306M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C1306M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco C1306M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco C1306M should contain:
- informations concerning technical data of Pelco C1306M
- name of the manufacturer and a year of construction of the Pelco C1306M item
- rules of operation, control and maintenance of the Pelco C1306M item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C1306M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C1306M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C1306M.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C1306M item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ExSite ™ EHXM Series Explosionproof Fixed System INSTALLATION C1306M (8/05)[...]

  • Page 2

    2 C1306M (8/05) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 3

    C1306M (8/05) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’ s instructions. 6. T o reduce the risk of ignition of hazardous atmospheres, disconnect the equipment from th[...]

  • Page 4

    4 C1306M (8/05) Getting Started Thank you for purchasing Pelco’ s ExSite ™ EHXM Series explosionproof system. This manual includes instructions for installing all the components of the system. Once the system installation is complete, refer to the operation/programming manual for instructions on how to operate and pro- gram your system. METHODS[...]

  • Page 5

    C1306M (8/05) 5 Install the Power Module Attach the power module to the mounting surface. Use only installation methods and materials capable of supporting four times the maximum specified load of the system (140 lb/63.5 kg). NOTE: If required, install the optional TXB translator , fiber module, or UTP board before installing the power module. Re[...]

  • Page 6

    6 C1306M (8/05) CONNECT WIRING Refer to the following information to connect the wires and cables as required. NOTES: • Relay 3 is allocated specifically for an external washer (not supplied by Pelco). • All relays are specified for 32 VDC, 0.5 A. • Wiring/cable for UTP and fiber optic are not provided on the wire harness. The installer mu[...]

  • Page 7

    C1306M (8/05) 7 DIP SWITCH SETTINGS Configure the receiver address, termination, and baud setting for the system. The DIP switches to configure these settings are located on the top of the power module. NOTE: No DIP switch settings are required for Coaxitron control. Figure 3 shows the default settings for the DIP switches. Refer to the following[...]

  • Page 8

    8 C1306M (8/05) ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 1 OFF OFF OFF OFF OFF OFF OFF OFF 2 ON OFF OFF OFF OFF OFF OFF OFF 3 OFF ON OFF OFF OFF OFF OFF OFF 4 ON ON OFF OFF OFF OFF OFF OFF 5 OFF OFF ON OFF OFF OFF OFF OFF 6 ON OFF ON OFF OFF OFF OFF OFF 7 OFF ON ON OFF OFF OFF OFF OFF 8 ON ON ON OFF OFF OFF OFF OFF 9 O[...]

  • Page 9

    C1306M (8/05) 9 ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OFF ON ON OFF OFF 52 OFF OFF ON OFF ON ON OFF OFF 53 ON OFF ON OFF ON ON OFF OFF 54 OFF ON ON OFF ON ON OFF OFF 55 ON ON ON OFF ON ON OFF OFF 56 OFF OFF OFF ON ON ON OFF OFF 57 ON OFF OF[...]

  • Page 10

    10 C1306M (8/05) T able B. D Protocol Receiver Address (Continued) ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 143 ON ON ON ON OFF OFF OFF ON 144 OFF OFF OFF OFF ON OFF OFF ON 145 ON OFF OFF OFF ON OFF OFF ON 146 OFF ON OFF OFF ON OFF OFF ON 147 ON ON OFF OFF ON OFF OFF ON 148 OFF OFF ON OFF ON OFF OFF ON 149 ON OFF ON OF[...]

  • Page 11

    C1306M (8/05) 11 ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 239 ON ON ON ON OFF ON ON ON 240 OFF OFF OFF OFF ON ON ON ON 241 ON OFF OFF OFF ON ON ON ON 242 OFF ON OFF OFF ON ON ON ON 243 ON ON OFF OFF ON ON ON ON 244 OFF OFF ON OFF ON ON ON ON 245 ON OFF ON OFF ON ON ON ON 246 OFF ON ON OFF ON ON ON ON ADDRESS SWITCH SET[...]

  • Page 12

    12 C1306M (8/05) Install the Camera Module To install the camera module, do the following: 1. Refer to Figure 4. Loosen the set screw at the back of the camera enclosure with the provided 1.5 mm Allen wrench. Figure 4. Loosen Set Screw 2. Use the supplied spanner wrench to loosen the back of the camera enclosure (refer to Figure 5). Once the back i[...]

  • Page 13

    C1306M (8/05) 13 3. Slide the camera module into the camera enclosure. Refer to Figure 6 to position the camera module properly in the camera enclosure. Carefully mate the camera’ s power connector to the mating connector located inside the camera enclosure. Models with a wiper: The tab located inside the camera enclosure must be pointing down be[...]

  • Page 14

    14 C1306M (8/05) 4. Models with a wiper: Refer to Figure 8 and do the following to install the arm of the wiper: a. Place the supplied green bushing on the stud located behind the handle of the camera module. The bushing should be in the same orientation as shown in Figure 8. b. Install the wiper arm. Place the ridge of the arm in the notch of the [...]

  • Page 15

    C1306M (8/05) 15 Install the Enclosure and Set Pan Position 1. Lightly apply O-ring lubricant (supplied) to the O-ring, and then install the O-ring on the rim of the power module (refer to Figure 9). Figure 9. Lightly Lubricate and Install O-Ring 2. Refer to Figure 10 and attach the enclosure unit to the power module. Align the pins of the enclosur[...]

  • Page 16

    16 C1306M (8/05) Set the T ilt Angle of the Camera Module 1. Place a 41 mm open end or crescent wrench on the tilt locking nut and a 21 mm open end wrench on the tilt shaft (refer to Figure 11). Figure 11. Set the T ilt Position 2. Hold the tilt shaft in position with the 21 mm wrench, and then turn the 41 mm wrench to loosen the tilt locking nut. [...]

  • Page 17

    C1306M (8/05) 17 Install the Sun Shroud 1. Place the supplied nylon washers on the 6-32 Phillips pan head screws. Refer to Figure 12. 2. Align the mounting holes of the sun shroud with the holes on top of the camera enclosure. 3. Use the supplied nylon washers and screws to secure the sun shroud to the camera enclosure. Figure 12. Install the Sun S[...]

  • Page 18

    18 C1306M (8/05) Maintenance CAMERA MODULE REPLACEMENT To replace the camera module, do the following: 1. Remove the back cap of the camera enclosure. Refer to Figure 13 and do the following: a. Loosen the set screw with a 1.5 mm Allen wrench. b. Use the supplied spanner wrench to loosen the back cap of the camera enclosure. Once the back is loose,[...]

  • Page 19

    C1306M (8/05) 19 3. Models with a wiper: Remove the wiper arm and the green bushing from the unit (refer to Figure 14). 4. Slide the camera module out of the enclosure. 5. Install the new camera module by doing the following: Slide the camera module into the camera enclosure. Refer to Figure 15 to position the camera module properly in the camera e[...]

  • Page 20

    20 C1306M (8/05) 6. Models with a wiper: Refer to Figure 14 and do the following to reinstall the arm of the wiper: a. Reinstall the green bushing on the stud located behind the handle of the camera module. b. Reinstall the wiper arm. Place the ridge of the arm in the notch of the camera enclosure tab and the slot of the arm over the green bushing.[...]

  • Page 21

    C1306M (8/05) 21 Specifications ELECTRICAL Input V oltage 24 V AC or 100-240 VAC Input V oltage Range ±10% Power Consumption Maximum 60 watts (120 V A) per system Heater and Defroster Microprocessor controlled Electrical Connections 6-foot wire harness with connections for power , video, data control, alarm inputs, and auxiliary outputs MECHANICA[...]

  • Page 22

    22 C1306M (8/05) *Manual control of camera setup functions can be done with CM6700, CM6800, CM8500, CM9500, CM9740, CM9760, CM9770, CM9780, KBD200A, KBD300A, and MPT9500 controllers, but not with CM7500, MPT9000, or KBD9000 controllers. CAMERA/OPTICS Camera Day/Night (23X) Color LowLight ™ (22X) Color Signal Format NTSC, P AL NTSC, P AL Scanning [...]

  • Page 23

    PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex ® Series [...]

  • Page 24

    W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East[...]