Pelco C1005M-G manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C1005M-G, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C1005M-G one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco C1005M-G. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco C1005M-G should contain:
- informations concerning technical data of Pelco C1005M-G
- name of the manufacturer and a year of construction of the Pelco C1005M-G item
- rules of operation, control and maintenance of the Pelco C1005M-G item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C1005M-G alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C1005M-G, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C1005M-G.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C1005M-G item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ICI1000PIM Personality Interface Module C1005M-G (10/02) ® INST ALLA TION/OPERA TION[...]

  • Page 2

    2 C1005M-G (10/02) GENERAL UNP ACKING INSTRUCTIONS Unpack and inspect all parts carefully . The following items are supplied: 1 ICI1000PIM Personality Interface Module 1 RJ-14 cable for Inter -Check ® and the DX2000 DVR 1 RJ-45 coupler for the DX2000 DVR DESCRIPTION The ICI1000PIM Personality Interface Module (PIM) is a data protocol translator th[...]

  • Page 3

    C1005M-G (10/02) 3 INST ALLA TION NOTE: The information in this manual is for PIM software version 4.02 and above. INST ALLA TION FOR INTER-CHECK Refer to the ICI1000S Inter -Check manual as you install the ICI1000PIM. 1. Configure DIP switch bank 1 on the PIM (refer to Configuring DIP Switch Bank 1 section). 2. Configure DIP switch bank 2 on the P[...]

  • Page 4

    4 C1005M-G (10/02) Figure 2. Configuration for Wiring ICI1000PIM Module WHITE BLUE BLACK YELLOW RED GREEN WHITE BLUE BLACK YELLOW RED GREEN STRAIGHT -THROUGH PHONE CABLE TO INTER-CHECK UNIT USER-SUPPLIED CABLE, 18 AWG, SHIELDED WIRE IS SUGGESTED FROM ICI1000PIM[...]

  • Page 5

    C1005M-G (10/02) 5 INST ALLA TION FOR DX2000 DVR AND DX2000DH DA T A HUB Refer to Figure 3 and the DX2000 Digital Video Recorder Installation/Operation Manual (C690M) and DX2000DH Data Hub Manual (C698M) as you install the ICI1000PIM. 1. Configure DIP switch bank 1 (refer to the Configuring DIP Switch Bank 1 section) for the device to which you are[...]

  • Page 6

    6 C1005M-G (10/02) Figure 4. ICI1000PIM Switch Locations 12 3 4 5 67 8 ON 12 3 4 5 67 8 REGISTER/INTERF ACE I PUT N BANK 1 BANK 2 D ATA POWER ON CONFIGURING DIP SWITCH BANK 1 The switches in this bank serve several purposes. Selections include polling or non-polling operation, PIM addressing, clock signal manipulation, and ICI1000PIM graphics mode [...]

  • Page 7

    C1005M-G (10/02) 7 Table A. PIM Address Settings for Switch Bank 1 + = OPEN (FLIP THE SWITCH DOWN) – = CLOSED (FLIP THE SWITCH UP) SWITCH # 45678 POLLING PIM ADDRESS (PIM #) – –––– 1 –––– + 2 ––– + – 3 –––+ + 4 –– + –– 5 –– + – + 6 – – + + – 7 –– + + + 8 – + – – – 9 – + – – + 1[...]

  • Page 8

    8 C1005M-G (10/02) Table B. Cash Register/Interface Configurations + = OPEN (FLIP THE SWITCH DOWN) X = POLLING/NON-POLLING R = RECEIPT (Normally CLOSED = – ) – = CLOSED (FLIP THE SWITCH UP) – = POLLING – = JOURNAL + = NON-POLLING + = SELECT G = GRAPHICS (Normally CLOSED = – ) Register/Interface T ype Bank 1 Switch Bank 2 Switch 123 123456[...]

  • Page 9

    C1005M-G (10/02) 9 Table B. Cash Register/Interface Configurations (Continued) Register/Interface T ype Bank 1 Switch Bank 2 Switch 123 12345678 P ANASONIC JS-6500 Dot Matrix Printer - X G + - - + + - + + RCALLEN RC204 Drum Printer + X - + - - + - + + + RUBY VERIFONE/RS-232 Standard Serial Printer + X + + - - - + - - + SAMSUNG 4900, 4915, 4940 Dot [...]

  • Page 10

    10 C1005M-G (10/02) SPECIFICA TIONS ELECTRICAL Power Input V oltage: 120 V AC, 60 Hz to wall mounted transformer (5 VDC, 300 mA from transformer to ICI1000PIM) Connectors: One 16-pin interface connector One RJ-14 modular data connector One transformer power connector DIP Switches: T wo eight-position DIP switches GENERAL Construction: Black plastic[...]

  • Page 11

    C1005M-G (10/02) 11 W ARRANTY AND RETURN INFORMA TION W ARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/M[...]

  • Page 12

    World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada ®[...]