Panasonic LE Relays manual

1
2
3
4
5

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Panasonic LE Relays, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panasonic LE Relays one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Panasonic LE Relays. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Panasonic LE Relays should contain:
- informations concerning technical data of Panasonic LE Relays
- name of the manufacturer and a year of construction of the Panasonic LE Relays item
- rules of operation, control and maintenance of the Panasonic LE Relays item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panasonic LE Relays alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panasonic LE Relays, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panasonic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panasonic LE Relays.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Panasonic LE Relays item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    LE (ALE) SPECIFICA TIONS 16A PO WER RELA Y FOR MICR O W A VE O VEN LE RELA YS (ALE) VDE 12.4 24.9 28.6 .488 .980 1.126 12.4 .488 28.6 1.126 24.9 .980 PCB type TMP type RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ FEA TURES 1. Supports magnetron and heater loads. Capable f or switching magnetron and heater loads f [...]

  • Page 2

    LE (ALE) ORDERING INFORMA TION TYPES 1. Standar d type ❍ : Input the follo wing letter . Class B: B, Class F: F 2. High sensitive type ❍ : Input the follo wing letter . Class B: B, Class F: F COIL D A T A (at 20 ° C 68 ° F ) 1. Standar d type Contact arrangement Coil voltage , V DC TMP type/PCB side three terminals (includes one dummy termina[...]

  • Page 3

    LE (ALE) 2. High sensitive type DIMENSIONS mm inch Nominal voltage , V DC Pick-up v oltage, V DC (max.) (at 20 ° C 68 ° F ) Drop-out voltage , V DC (min.) (at 20 ° C 68 ° F ) Coil resistance, Ω ( ± 10%) (at 20 ° C 68 ° F ) Nominal operating current, mA ( ± 10%) (at 20 ° C 68 ° F ) Nominal operating power , mW (at 20 ° C 68 ° F ) Maxim[...]

  • Page 4

    LE (ALE) REFERENCE D A T A PCB side f our terminals mm inch 6.0 0.5 4.75 2.45 1.0 1.0 1.8 3.5 0.5 0.4 24.9 28.6 20.0 3.5 6.35 8.5 7.5 12.4 #187 terminal 0.8 0.8 Dimension: Max. 1mm 1 to 3mm Min. 3mm .118 inch Tolerance ± 0.1 ± 0.2 ± 0.3 ± .004 ± .008 ± .012 .039 inch .039 to .118 inch : : : .236 .020 .187 .096 .039 .039 .071 .138 .020 .016 .9[...]

  • Page 5

    LE (ALE) For Cautions f or Us e , see Rel a y T e c hnical In f ormation. 3. Electr ical lif e test (16 A 277 V AC , resistive load) Sample: ALE14B12, 6 pcs. Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: Room temperature Circuit: 60Hz 12V DC COM NO G 277V AC 0 0 20 10 40 30 50 60 70 10 Max. Min. x Max. Min. x Pick-up[...]