Panasonic EX-10 Series manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Panasonic EX-10 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panasonic EX-10 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Panasonic EX-10 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Panasonic EX-10 Series should contain:
- informations concerning technical data of Panasonic EX-10 Series
- name of the manufacturer and a year of construction of the Panasonic EX-10 Series item
- rules of operation, control and maintenance of the Panasonic EX-10 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panasonic EX-10 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panasonic EX-10 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panasonic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panasonic EX-10 Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Panasonic EX-10 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EX-10 Ultra-slim Photoelectric Sensor Amplifier built-in extraordinarily small and slim size 226 SERIES Smallest body , just 3.5 mm 0.138 in thick High-speed response time: 0.5 ms Flexib le mounting It can be mounted in a very small space as its size is just W10  H14.5  D3.5 mm W0.394  H0.571  D0.138 in (thru- beam, front sensing type).[...]

  • Page 2

    227 EX-10 APPLICA TIONS V erifying position of PCBs Detecting ICs Detecting PCB rack EX-14  Transparent stick IC EX-15 EX-19  Detecting wafer cassette Detecting thin ring Checking f or absence of capacitor in tray EX-14  Guide EX-13E  EX-14  Mountable with M3 scre ws Minimum sensing object: " 1 mm " 0.039 in Long sensing ra[...]

  • Page 3

    228 EX-10 Light-ON Dark-ON Light-ON Dark-ON Light-ON Dark-ON Light-ON Dark-ON Light-ON Dark-ON Light-ON Dark-ON ORDER GUIDE 500 mm 19.685 in 150 mm 5.906 in 500 mm 19.685 in 150 mm 5.906 in 500 mm 19.685 in 150 mm 5.906 in 500 mm 19.685 in 2 to 25 mm 0.079 to 0.984 in (Note) (Conv ergent point: 10 mm 0.394 in ) 150 mm 5.906 in T ype Appearance Sens[...]

  • Page 4

    229 EX-10 ORDER GUIDE Flexible cab le type and 5 m 16.404 ft cable length type Flexib le cable type and 5 m 16.404 ft cab le length type (standard: 2 m 6.562 ft ) are also availab le. • T able of model Nos. EX-11A EX-11B EX-13A EX-13B EX-19A EX-19B EX-15 EX-17 EX-11EA EX-11EB EX-13EA EX-13EB EX-15E EX-17E EX-14A EX-14B EX-11A-R EX-11B-R EX-13A-R [...]

  • Page 5

    230 EX-10 Slit on both sides  Sensing range: 500 mm 19.685 in [ EX-19  ] 300 mm 11.811 in [ EX-13  ]  Min. sensing object: " 1.5 mm " 0.059 in Designation Model No . Description Mounting brack et f or the front sensing type sensor [Cold rolled carbon steel (SPCC)] (The thru-beam type sensor needs two brack ets.) Mounting brack[...]

  • Page 6

    231 EX-10 12 to 24 V DC  10 % Ripple P-P 10 % or less < NPN output type > NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) 0.4 V or less (at 16 mA sink current) < PNP output type > PNP open-collector tr[...]

  • Page 7

    232 EX-10 I/O CIRCUIT AND WIRING DIA GRAMS EX-11  EX-13  EX-19  EX-14  I/O circuit dia gram NPN output type PNP output type NPN output type Wiring diagram Users’ circuit Internal circuit Color code 50 mA max. Sensor circuit Tr D Z D Load (Brown)  V (Black) Output (Note) (Blue) 0 V   12 to 24 V DC  10 % Not e: The emitter o[...]

  • Page 8

    233 EX-10 All models SENSING CHARA CTERISTICS (TYPICAL) Correlation between setting distance and excess gain 0 200 7.874 600 23.622 800 31.496 1,000 39.370 1 10 5 100 400 15.748 Excess gain 50 EX-13  EX-17  EX-11  EX-15  Setting distance L (mm in ) 01 3.281 3 9.843 4 13.123 5 16.404 1 10 5 100 2 6.562 Excess gain 50 Setting distance L ([...]

  • Page 9

    234 EX-10 Operation mode switch L : Light-ON D: Dark-ON Lights up when the output is ON. Operation indicator (Orange) Switch position Description • V ertical (up and down) direction SENSING CHARA CTERISTICS (TYPICAL) Conv ergent reflectiv e type Sensing fields • Horizontal (left and right) direction Correlation between lightness and sensing ran[...]

  • Page 10

    235 EX-10 EX-11A  EX-11B  EX-13A  EX-13B  EX-19A  EX-19B  Sensor Emitter Receiver 2- " 2.2 " 0.087 mounting holes Beam- emitting part 11 0.433 1.75 0.069 4.5 0.177 14.5 0.571 5.5 0.217 10 0.394 1.75 0.069 2.1 0.083 3.5 0.138 " 2.5 " 0.098 cable, 2 m 6.562 ft long 6.5 0.256 4 0.157 2.1 0.083 4 0.157 3.5 0.138 5.[...]

  • Page 11

    236 EX-10 DIMENSIONS (Unit: mm in ) EX-14A  EX-14B  Sensor Stability indicator (Green) Operation indicator (Red) 1.75 0.069 2.75 0.108 6.45 0.254 13 0.512 2.1 0.083 3.5 0.138 4.5 0.177 Beam- receiving part Beam-emitting part 2- " 2.2 " 0.087 mounting holes " 2.5 " 0.098 cable, 2 m 6.562 ft long 4.5 0.177 14.5 0.571 11 0.43[...]

  • Page 12

    237 EX-10 DIMENSIONS (Unit: mm in ) MS-EX10-3 Sensor mounting brac ket (Optional) 4-M2  0.4 0.016 thru-hole threads 2 0.079 6.5 0.256 3.2 0.126 8 0.315 10.8 0.425 7 0.276 10.5 0.413 1.4 0.055 11 0.433 15 0.591 t 1.2 t 0.047 Beam- receiving part Beam- emitting part (2.75) (0.108) 10.8 0.425 t 1.2 t 0.047 (0.7) (0.028) 13 0.512 5 0.197 1.75 0.069 [...]

  • Page 13

    238 EX-10 DIMENSIONS (Unit: mm in ) MS-EX10-13 Sensor mounting brac ket (Optional) 4-M2  0.4 0.016 thru-hole threads t 1.2 t 0.047 10.8 0.425 11 0.433 10.5 0.413 6.5 0.256 3.2 0.126 2 0.079 15 0.591 7 0.276 1.4 0.055 1.4 0.055 8 0.315 3.2 0.126 11 0.433 3.2 0.126 1.25 0.049 4.25 0.167 15 0.591 8 0.315 3 0.118 3.2 0.126 1.4 0.055 13 0.512 10.5 0.[...]