Panasonic AQ-C Relays manual

1
2
3
4
5

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Panasonic AQ-C Relays, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panasonic AQ-C Relays one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Panasonic AQ-C Relays. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Panasonic AQ-C Relays should contain:
- informations concerning technical data of Panasonic AQ-C Relays
- name of the manufacturer and a year of construction of the Panasonic AQ-C Relays item
- rules of operation, control and maintenance of the Panasonic AQ-C Relays item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panasonic AQ-C Relays alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panasonic AQ-C Relays, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panasonic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panasonic AQ-C Relays.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Panasonic AQ-C Relays item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    A Q-C ORDERING INFORMA TION TYPES 1. Input module Standard packing: Car ton: 50 pcs.; Case: 500 pcs . Miniature DIL 1A contr ol type f or PCBs A Q-C RELA YS T ype Output voltage Input voltage P ar t No. AC input 4 to 32 V DC 80 to 250 V AC AQCD3-IM 100/240 V A C DC input 4 to 32 V DC 3 to 32 V DC AQCD3-IM 4/24 V DC Please contact us about TÜV cert[...]

  • Page 2

    A Q-C 2. Output module Standard packing: Car ton: 50 pcs.; Case: 500 pcs . Note: Rev erse polar ity type (AQC5 ∗∗ and A QC6 ∗∗ ) is also produced by lot after receipt of order . SPECIFICA TIONS Rating [at 20 ° C 68 ° F ; Input voltage ripple (output module) and output voltage ripple (input module): max. 1%] 1. Input module 2. Output modul[...]

  • Page 3

    A Q-C Characteristics [at 20 ° C 68 ° F ; Input voltage ripple (output module) and output voltage ripple (input module): max. 1%] Input module Output module REFERENCE D A T A T ype Item AC Input DC Input Remarks Operate time, max. 20 ms 0.5 ms Input voltage: 24 V DC or 100V AC Output voltage: 24 V DC Output current: 25mA Release time, max 20 ms 0[...]

  • Page 4

    A Q-C DIMENSIONS (mm inch ) A CCESSOR Y 5. Load current vs. ambient temperature characteristics for adjacent mounting =12.7 mm =20.32 mm –30 0 20 40 60 80 0 Ambient temperature, ° C Load current, A 0.2 0.4 0.6 0.8 1.0 =Adjacent mounting pitch .500 inch .800 inch The CAD data of the products with a CAD Data mark can be downloaded from: http://pan[...]

  • Page 5

    A Q-C NO TE For Cautions f or Us e . When used for the load less than rated In the case of the load current less than rated, malfunction ma y result from the residual voltage across the both ends of the load e ven if the solid state rela y is turned off. Use a dummy resistor as a countermeasure. The total of the current through the resistor and the[...]