Panasonic AJ9 (J9) manual

1
2
3
4
5
6

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Panasonic AJ9 (J9), along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panasonic AJ9 (J9) one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Panasonic AJ9 (J9). A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Panasonic AJ9 (J9) should contain:
- informations concerning technical data of Panasonic AJ9 (J9)
- name of the manufacturer and a year of construction of the Panasonic AJ9 (J9) item
- rules of operation, control and maintenance of the Panasonic AJ9 (J9) item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panasonic AJ9 (J9) alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panasonic AJ9 (J9), and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panasonic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panasonic AJ9 (J9).

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Panasonic AJ9 (J9) item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    AJ9 (J9) CONSTR UCTION PO WER R OCKER SWITCH AJ9 (J9) SWITCHES VDE AJ9 s witch snap-in mounting type AJ9 s witch screw mounting type FEA TURES 1. P ower roc ker switches f or safety requirements. • All versions comply with Class II EN61058-1 insulation grade . Insulation distance: 8mm Min. Contact gap: 3mm Min. • International Standard-appr o v[...]

  • Page 2

    AJ9 (J9) ORDERING INFORMA TION PR ODUCT TYPES 1. Snap-in mounting type (1) Without indication on actuators (Standard flange color is blac k. For other colors type, they are custom ordered.) Remarks: 1. A letter indicating the actuator color is entered in place of ∗ symbol. (W: White B: Blac k R: Red Z: Dar k gra y H: Light gray L: Blue G: Green [...]

  • Page 3

    AJ9 (J9) (2) With indication on actuators (Standard flange color is blac k. For other colors type, they are custom ordered.) Remarks: 1. A letter indicating the actuator color is entered in place of ∗ symbol. (W: White B: Blac k R: Red Z: Dar k gra y H: Light gray L: Blue G: Green Y : Y ellow) For requests of other flange color , please suffix[...]

  • Page 4

    AJ9 (J9) SPECIFICA TIONS 1. Contact rating Remark: The motor load is in accordance with EN61058-1. Inr ush current can be s witched up to the value of 6 times the indicated rating. 2. Characteristics Remark: T est conditions are in accordance with EN61058-1, UL1054 and JIS C 6571. DIMENSIONS mm General tolerance: ± 0.5 T ype V oltage Resistive loa[...]

  • Page 5

    AJ9 (J9) 2. Screw mounting type 15 29 19 0.8 1.75 dia. 4.4 30 ° 33 0.8 9.7 6.35 11 7.5 4 34 19.9 15 1.2 7 10 12.4 50 42 ± 0.2 OFF ON 2-pole 1-pole Remark: For soldering compatib le with .250 Quick-connect terminal and PC board terminal, only ter minal shape is changed. mm General tolerance: ± 0.5 2) Soldering compatible with .250 Quick-connect t[...]

  • Page 6

    AJ9 (J9) NO TES REFERENCE 1. Switch mounting Mount the s witch with the recommended panel mounting hole dimensions shown in the dimensions. Contact us if you are considering using a panel of other than the recommended size and shape . 2. Regar ding fastening lead wires to terminals 1) When connecting the tab terminals, use a .250 Quick-connect and [...]