A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Panamax M1500-UPS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panamax M1500-UPS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Panamax M1500-UPS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Panamax M1500-UPS should contain:
- informations concerning technical data of Panamax M1500-UPS
- name of the manufacturer and a year of construction of the Panamax M1500-UPS item
- rules of operation, control and maintenance of the Panamax M1500-UPS item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panamax M1500-UPS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panamax M1500-UPS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panamax service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panamax M1500-UPS.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Panamax M1500-UPS item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MAX ® Home Cinema UPS Owner’ s Manual POWER TEST M AX ® Hom e Cinem a UPS Pure Sine Wave  Intelligent Critical Load Control UNSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL 1690 Corporate Circle, Petaluma, CA 94954 • www .panamax.com M1500-UPS[...]

  • Page 2

    © 2005 P ANAMAX CORP . All Rights Reserved. P ANAMAX, the Panamax logo and MAX are registered US trademarks of Panamax. Protect or Disconnect, and SignalPerfect are trademarks of PANAMAX. SIDACtor is a registered US trademark of T eccor Electronics, Inc. TiV o is a trademark of TiVo, Inc. Important Safety Instructions..............................[...]

  • Page 3

    POWER TEST M AX ® Hom e Cinem a UPS Pure Sine Wave  Intelligent Critical Load Control UNSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL MODEL # M1500-UPS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read and follow all ins[...]

  • Page 4

    Installing Y our UPS HARDWARE INST ALLA TION GUIDE 1. Y our new UPS may be used immediately upon receipt. However , recharging the batter y for at least four hours is rec- ommended to insure that the battery’ s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery , simply leave the unit p[...]

  • Page 5

    UNSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL 1 2 3 4 RS232 CONTROL CRITICAL LOAD OUTLET BANK NON CRITICAL LOAD OUTLET BANK AC INPUT IR1 IR OUTPUT PROGRAM / TEST 30 SEC. 5 MIN. IN OUT OUTPUT DELAY IR DETECTOR IR2 MAIN 3 2 1 Basic Operation (continued) Power On Indicator This LED is illuminated when the utility co[...]

  • Page 6

    4 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Advanced Operation Audio/Video components such as Digital Video Recorders, DLP projectors and any component with volatile memory can benefit from connection to a UPS. The Panamax M1500-UPS takes this to the next level with a number of features designed specifically for the [...]

  • Page 7

    5 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 5. If the learning process was successful, the controlled equip- ment should accept the IR command and turn off or go into standby mode. 6. Reprogram the IR command if the controlled equipment does not respond. a . Be sure that the batteries in the “teaching remote” are[...]

  • Page 8

    6 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 5. Windows will recognize your UPS as “New Hardware”. 6. Insert the software disk into the computer’ s drive. The instal- lation program should start automatically . If the installation pro- gram does not start automatically , open it manually with the Window’ s “[...]

  • Page 9

    7 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Home Cinema Power Control Software Instructions Overview Panamax’ s Home Cinema Power Control software is designed for use with Windows 95, Windows 98, Windows Me, Windows NT , Windows 2000 and Windows XP . It works in conjunction with the UPS to provide full protection o[...]

  • Page 10

    8 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Home Cinema Power Control Software Instructions (continued) MAIN WINDOW DESCRIPTIONS SETUP MENU 2. Input Voltage: Shows the current input voltage. The input normally appears in green, but will turn red if the input voltage is lower than 85v or higher than 150v . 9. Schedule[...]

  • Page 11

    9 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Home Cinema Power Control Software Instructions (continued) ADV ANCED SETUP MENU SCHEDULE MENU - SPECIAL 1. Low Battery HTPC Shutoff: For use with a Home Theater PC. Sets the low battery cutoff level. The user can slightly extend the UPS run time by adjusting this setting. [...]

  • Page 12

    2. Event: When this option is selected, the log will display a list of events such as power failure, program start, and program end. 3. Closed Application Information: When this option is selected, the log will display the names and location of any files that were auto-saved by the software. 1. Log Display: This window displays the information as s[...]

  • Page 13

    Diagnostics UNSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL M A X ® Hom e C inem a UPS P ure S ine Wave Intelligent Critical Load Control 11 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Batter y Features (continued) Battery Replacement Procedure 2. Remove the two retaining screws of th[...]

  • Page 14

    T roubleshooting T echnical Specifications 12 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 AC SPECIFICA TIONS CAP ACITY (V A)__________________________________________________________1500V A (Watts)________________________________________________________1000W INPUT V oltage Range_________________________________________[...]

  • Page 15

    RS232 Communications Protocol & Command Set 13 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Communications Protocol Controller Commands Commands and responses are in the form of ASCII character strings terminated with a carriage return <CR> ASCII character 13 (hex). It is important to understand how the UPS ci[...]

  • Page 16

    RS232 Communications Protocol & Command Set (continued) 14 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Non Critical Load Outlets On This command controls the relay that feeds power to the NCL Outlets. Note that if the MAIN relay is off, the outlets will still be un-energized. Send to UPS: NCL_ON<CR> Action: N[...]

  • Page 17

    15 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 RS232 Communications Protocol & Command Set (continued) Request Input Voltage Level T ransmit the input AC voltage status Send to UPS: ?INPUTVOL TS<CR> Response from UPS: XXX<SP>VAC<SP>IN<CR> XXX is the input AC voltage represented in ASCII. Req[...]

  • Page 18

    16 USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 RS232 Communications Protocol & Command Set (continued) Condition CL Outlet Bank switches ON CL Outlet Bank switches OFF NCL Outlet Bank switches ON NCL Outlet Bank switches OFF Response from UPS CL_OUTLETS_ON<CR> CL_OUTLETS_OFF<CR> NCL_OUTLETS_ON<CR>[...]

  • Page 19

    FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reason- able protection against harmful interference in residential installation. This equipment gener- ates, uses, and can radiate radio frequency energy and, if not [...]

  • Page 20

    1690 Corporate Circle, Petaluma, CA 94954 Te l: (707) 283-5900 Fax:: (707) 283-5901 Email: sales@panamax.com W eb: www .panamax.com © 2005 Panamax INS0763 REV . B 7/05[...]