Omron HBP-1300 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron HBP-1300, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron HBP-1300 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron HBP-1300. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron HBP-1300 should contain:
- informations concerning technical data of Omron HBP-1300
- name of the manufacturer and a year of construction of the Omron HBP-1300 item
- rules of operation, control and maintenance of the Omron HBP-1300 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron HBP-1300 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron HBP-1300, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron HBP-1300.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron HBP-1300 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Profe ssional Blood Pressur e Monitor HBP-1300 • Instruction Manual • Mode d’em ploi • Gebrauchsanweisung • Manuale di istruzion i • Manual de instrucciones • Gebruiksaanwijzing •             • Kullanm Klavuzu EN FR DE IT ES IM-HB P-13 00-E -01-0 2/20[...]

  • Page 2

    Content s Intr oduction Intend ed Use ........ ................. ........... ................. ........... ................. ........... ................. .... 1 Exemp tions ........... ........... ................. ........... ................. ........... ................. ........... .......... 1 Notes o n Safety ............... ................[...]

  • Page 3

    1 EN Introduction Intended Use Medical Purpos e The device is a digital m onitor intended for use in measuring blood pressure and pulse rate in adult and pediatric patient population with arm circumference ranging from 12 cm to 50 cm (from 5 inches to 20 inches). Intend ed User This device should be used by a medical prof essional. Pa tie n t Po pu[...]

  • Page 4

    2 Notes on Safe ty The warning signs and symbol exa mples indicated below are intended t o ensure safe us e of the product and prevent damage and injury to you and others. The signs and symbols are explained below . Safety Symbols used in this Inst ruction Manual Wa r n i n g Ind icates the matte rs in which dea th or severe bodily damage may arise[...]

  • Page 5

    3 EN W arnings and Cautions Usage warni ngs and cau tions Setup Wa r n i n g Caution Do not use t he cuff or AC adapt er to lif t the unit, it c an also caus e the unit to m alfunction. If the unit has brok en dow n, contact OMRON HEAL THCARE. Do not use in combination w ith a hyperbaric oxygen therapy device, or in an environment where combustible[...]

  • Page 6

    4 Before use / during use Wa r n i n g The unit complies with the EMC st anda rd (IEC60601-1-2). As such, it can be used simult aneously with multiple medical instrument s. However , if instruments t hat generate noise such as an electric scalpel or a microwave therapy device are near the unit, check the operation of the uni t during and after use [...]

  • Page 7

    5 EN Caution Before using the unit, verify that none of t he following apply to t he pati ent: - Poor peripheral circulation, noticeably low blood pressure, or low body temperature (there will be low blood f low to the measurement position) - The p atient uses an artificial heart and lung (there will be no pulse) -A n S p O 2 sensor and the c uf f [...]

  • Page 8

    6 Cleanin g Wa r n i n g Cauti on Maintena nce a nd insp ection Wa r n i n g When cleaning the unit, t urn off the power and disconnect the AC adapter from the unit. After cl eaning the unit, make sure it is completely dry before connecting to a power outlet. Do not spray , pour , or spill liquids into or on to the unit, acce ssories, connect ors, [...]

  • Page 9

    7 EN W arnings and c autions for safe measurem ent Recha rgeab le b atte ry Wa r n i n g Caution If battery fluid comes in contact with the eye, immediately flush with copious amounts of water . Do not rub. Seek m edical attention immediately . Do not use t he battery pack in any other device besides this unit . Do not throw into flame, disassemble[...]

  • Page 10

    8 Non-Inva sive Bloo d Pre ssure (NI BP) meas ure ment Wa r n i n g Cauti on If a cuf f is used on a pat ient with an inf ection, treat the cuff as medical waste, or disinfect before reuse. If frequently performing NIBP measurement using a cuf f over an extended period of time, periodically check the patient’ s circulation. In addition, wrap t he[...]

  • Page 11

    9 EN Note: Setup • Read and understand the manual for each optional accessory . This manual does not contain cautionary inf ormation for optional acces sory . • Exercise caution with the cables and arrange so t hat the pat ient does not become entangled or bound. Bef ore us e / du r in g use • Check the following af ter turning on the power: [...]

  • Page 12

    10 Using the Unit Component s of the Product Before using the unit, make sure that no accessories are missing and that the unit and accessories are not damaged. If an accessory is missing or there is damage, please contact OMRON HEAL THCARE. Main unit S tand ard Medi cal Accesso r ies • GS CUFF L (32 - 42 cm)/ M (22 - 32 cm) • AC ad apter Other[...]

  • Page 13

    11 EN Optiona l Medi cal Acce ssori es (within the scope of EC Medical Device Directive 93/42/EEC) * UK plug type AC AD APTER-UK 1600 (9994843-9) Caution Only O MRON G S CUFF can be us ed with this device. Features of the Produc t The OMRON HBP- 1300 is an af f ordable professional blood pressure unit that is clinical ly proven accurate and provide[...]

  • Page 14

    12 Features / Functions of Unit Front an d back of un it Meanin g of t he Sy mbols 1 [ST A RT/STOP ] butto n (Pow er ON /OFF) Power ON / Measure blood pressure Pres s when the p ower is of f to tur n on th e power and st art blood pre ssure measur ement. During infla tion or measu rement, press to stop. Powe r OFF Hold down at least 3 sec onds to t[...]

  • Page 15

    13 EN LCD Display * O nly when the battery is inst alled. 1 SYS Displays sys tolic bloo d pressure . 2 DIA Displays diast o lic blood pres sure. 3 Pulse Displays the pulse rate. 4 Puls e synchronizatio n icon Flashes in syn chroniz ation wit h the pulse duri ng measur ement. 5 Irre gular pul se wave icon Light s in the meas urement result dis play [...]

  • Page 16

    14 Inst a lling the Battery Pac k Cauti on Do not short the positive and negative terminals of the battery pack with a wire or other metal object. If battery fluid comes into cont ac t with t he skin or clothes, immediately rinse with wat er . 1. Make su re the AC adap ter has been d isconn ected . 2. Remove the two screws from the top of the rear [...]

  • Page 17

    15 EN Battery ch arging Battery lev el Connecting the AC Adapter AC power V erify that the power out let supplies the specified voltage and frequenc y (100 - 240 V AC, 50/60 Hz). Connect the AC adapter to the DC jack on the unit and the power outlet. Note: When the ba tt ery pack is i nst alle d If there is no pr oblem with the f ollowing. - A C ad[...]

  • Page 18

    16 Syste m Settings The syst em settings are divided into t wo modes, “ Menu Mode” and “Ut ility Mode”. Menu Mode “Menu Mo de” al low s yo u to co nfig ure t he “I niti al In flatio n Pr ess ure V alue ” an d “Au sculta tion Mode ” set tin gs. 1. Press the [MODE] butt on. The “Initial Inflation Pressure V a lue” setting scre[...]

  • Page 19

    17 EN Utility Mode “Utility M ode” a llows y ou to con figure th e “Auto Powe r Off” and “Pr essure Accurac y Confir mation ” setting. 1. Con fir m tha t th e d evi ce i s swit ched o f f. If the power i s on, hold down t he [ST ART/STOP] button for at least 3 seconds t o turn of f the power . 2. Hold down the [MODE] butto n until the ?[...]

  • Page 20

    18 Non-Invasive Blood Press ure (NIBP) Measurement Non-Invasi ve Pressure Measur ement Principle s Oscillometric method The beat in t he pulsation generated by the contraction of the heart is captured as t he pressure inside the cuff to measure the blood pressure. If t he cuff wrapped around t he upper arm is pressurized suf ficiently , the blood f[...]

  • Page 21

    19 EN Cuff Selection and Connection Selectin g the cuff Caution • D o not us e the cuff if it is da maged or has ho les. • U se the appropriate cu ff size to ensur e correct m easurements. If a cuff that is too larg e is used, the measured blood press ure value tends to be lower t han the actual blood pressure . If a cuf f that is too small is [...]

  • Page 22

    20 Applying the Cuff to the Patient 1. Wrap on a bare arm or over thin clothing. Wrap t he cuff on a bare arm or over thin clothi n g . Thick clothing o r a rolled up sleeve will cause inaccurate blood pressure measu rements. The device can be used on either the right or left arm. 2. A lign the ar tery mark “I NDEX AR TER Y” with the br achial [...]

  • Page 23

    21 EN Caution Make sure the cuff is wrapped in the correct arm position an d is at the same he ight as the h eart. A dif ference of 10 cm (4 inches) in hei ght may cause a variation in the blood pres sure value of up to 7 - 8 mmHg. Note: • I f meas urement is dif fic ult due to arrhyt hmia, use a di f feren t blood pressure measure ment met hod. [...]

  • Page 24

    22 Irregula r pulse w ave detect ion function If the pulse wav e interval becom es irregular dur ing measurem ent, the irregular puls e wave det ection icon will light to notify you. Body m ovemen t detectio n function If body m ovement is d etected during measure ment, deflation st ops for 5 seco nds. T he irregular pulse wave icon appears in the [...]

  • Page 25

    23 EN S topping the Meas urement T o stop measurement while measurement is in progress, press [ST ART/STOP] button. Displayi ng Last Reading The previous meas urement value (systolic blood pressure, diastolic blood pres sure, and pulse rat e) and whether or not an irregular pulse wave was det ected can be displayed. In t he case of auscultation mea[...]

  • Page 26

    24 Maintenance Maintenance In spection and Safe ty Management The HBP-1300 must be maintained to ensure func tionality and to secure the saf ety of patien t s and operators. Daily checks and maintenance should be per formed b y the operator . (page 25) In addition, qualified personnel are necessary to maint ain the performance and the sa fety , and[...]

  • Page 27

    25 EN Check be fore Use Before cond ucting safety checks, be su re to imple ment the items in the “Cleaning of the D evice” and “A ccessory Care” sect ions. (page 24) Before turning on t he power Before t urning on the power , check f or the following External appear ance Q The device or accessories are not deformed due to falling or other [...]

  • Page 28

    26 T roubleshooting The power do es not turn on Cause S olutio n If the un it is being powered by the bat tery , the batte ry is not ins ta lled or the charge is depl eted. Insert ba ttery or replace with a ne w batter y (page 14 ). Inte rnal part f ailu re Discon nect the AC ad apter , remo ve t he b attery , and conta ct OMRON HE AL THCAR E. • [...]

  • Page 29

    27 EN Abnormal measurement value Cause / solu tion The causes below are possi ble. Chec k th e pat ient by pa lp ation and th en repeat measure ment. • Body movement (chil ls or oth er tremblin g) • Arrhythmia. • Noi se in the c uff - A nearb y pe rson touc hed t he p atient. - Cardiac mass age was bei ng performed. The meas urement va lue is[...]

  • Page 30

    28 List of Error Codes The alarm lamp flashes when a medi um-priority alarm occur s, and light s steadily when a l ow-priority alarm occurs. T o clear an alarm, press any button. Q If a low-priority alarm and a medium -priority alarm occur at the sam e time, the medium-priority alarm is displayed. If the alarms are the same priority level, the erro[...]

  • Page 31

    29 EN Other problem s Disposal Descriptio n As there is a risk of environmental pollution, follow y our applicable national and local legal regula tions regarding dispos al or recy cling of this equipment and batteries. The main constituents of each p a rt are li sted in the t able below . As there is a risk of inf ection, do not recycle patient at[...]

  • Page 32

    30 S peci ficat ions Factory Default Settings Factory default settings and backup are as shown below . Backup : Setting i s retained even i f the power is interrupted. : Reverts t o factory default setting if the power i s turned off. T echnica l Specifications: HBP-130 0 Main unit Power sup ply Sett ing Pr ess ure V al ue Setti ngs Factory Se ttin[...]

  • Page 33

    31 EN Environme ntal Conditions Non-Invas ive Blood Pressure (NI B P) * C omparison with auscultation method performed by a trained prof essional. DIA determined by the auscultation method is “K5”. Note: S pecifications m ay be c hanged without prior notice. This blood pressure monitor fulfils the requirements of the EC directive 93/42/EEC (Med[...]

  • Page 34

    32 Important information regarding Elec tro Magnet ic Compatibility (EMC ) With the increased number of electronic devices such as PC’ s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrec t operation of t he medical de [...]

  • Page 35

    33 EN Manufacturer ’ s Declarat ion The HBP -1300 is inte nded for use in the electromag netic environm ent specified below . The cust omer or the user of the HBP- 1300 should ass ure that it is used in such an environment . Electromagnetic E missions: (IEC6 0601-1-2) Electromagnetic I mmunity: (IEC6 0601-1-2) Emissi on T est Compliance Elec trom[...]

  • Page 36

    34 Immunity test IEC60601-1-2 test level Compliance level Electromagneti c environment - guidance Conduct ed RF IEC 61000-4 -6 Radiat ed RF IEC 61000-4 -3 3 V rms 150 kHz to 80 MH z 80% A M ( 2H z) 3V / m 80 MH z to 2.5 GH z 80% A M ( 2H z) 3 V rms 3 V/m Port able and mobile RF communicat ions equipmen t shoul d be used no close r to any p art of t[...]

  • Page 37

    35 EN Recomm ended Separation Distances: Recommended separation dist anc e between port able and mobile RF commun ications equipment and the HBP-1300 The HBP- 1300 is intend ed for u se in an elec troma gnetic en v ironme nt in whic h radia ted RF dis turban ces are co ntrolled . The customer or the user of the HBP-1 300 can help preve nt elec trom[...]

  • Page 38

    Made in C hina Manufacturer OMRON HEAL THCA RE Co., Lt d. 53, Kunotsubo, T era do-cho, Muko, Kyoto, 617-0002 JAP AN EU-rep resent ative OMRON HE AL THCARE EUROPE B .V . Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www .omron-healthcare. com Product ion facility OMRON (DALIAN) CO., L TD. Dalian, CHINA S ubs id ia ry OMRON HEAL THCA RE UK L TD. Op[...]