Omron E5GN manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron E5GN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron E5GN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron E5GN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron E5GN should contain:
- informations concerning technical data of Omron E5GN
- name of the manufacturer and a year of construction of the Omron E5GN item
- rules of operation, control and maintenance of the Omron E5GN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron E5GN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron E5GN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron E5GN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron E5GN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Digital T emperature Controller E5GN Compact and Intelligent 1/32 DIN T emperature Controller with Communications Function  Auto-tuning and sel f-tuning avai lable. Can auto-tune even duri ng execution of self-tuning  V arious temper ature inputs: thermocouple, pl atinum resistance thermometer , non-contact temperature sensor , and analog inp[...]

  • Page 2

    E5GN E5GN E5GN CO MMUNI CA TION M ODELS IMPORT ANT : The alarm function is NOT available with the communications models. Descrip tion Part number Size Power supply voltage Communicat ion functi on Output Thermocouple model Platinum resistance therm ometer model 1/32 DI N 4 8 ( W ) 100 to 240 V A C RS-485 Relay E5GN-R03TC-FLK AC100-240 E5GN-R03P-FLK[...]

  • Page 3

    E5GN E5GN INPUT RANG ES Platinum Resistance Thermometer Input/Thermocouple Input T emperature range 1800 1700 1600 1500 1400 1300 1200 1 100 1000 900 800 700 600 500 400 300 200 100 0 - - 100 - - 200 Pt100 JPt100 Input type Platinum resistance thermometer input Platinum resistance thermometer Name 850 Set value 12 3 4 - -200 500.0 - -199. 9 100.0 0[...]

  • Page 4

    E5GN E5GN Specifications RA TINGS Supply voltage 100 to 240 V AC, 50/60 Hz 24 V AC, 50/60 Hz/24 VDC Operating v oltage range 85% to 1 10% of rat ed supply volt age Power cons umption 7V A 4V A / 2 . 5W Sensor i nput Thermocouple: K, J , T , E, L, U, N, R, S , B Platinum resis tance t hermometer: Pt100, JPt 100 Non-contac t tem perature sens or: K 1[...]

  • Page 5

    E5GN E5GN Characteristics T able - - c ontinued from previ ous page Weight Approx. 90 g Mounting bracket: approx. 10g Protective structur e Front Panel NEMA 4 for indoor use (equi valent to IP 66) Rear Case IP20 T erminals IP00 Memory protecti on EEPROM (non-volatile memory ) (number of writes : 100,000) EMC Emis sion E nclosure: EN5501 1 Group 1 c[...]

  • Page 6

    E5GN E5GN Nomenclature E5GN T emperature Unit The temperat ure unit is dis played when the di splay unit paramet er is set t o a t emperature. Indicat ion is determined by the currently select ed “temperature unit ” parameter set v alue. When this parameter is set to “ ° C,” “ ” is dis played, and when s et to “ ° F, ” “ ” is [...]

  • Page 7

    E5GN E5GN Dimensions Unit: mm (in ch) E5GN Panel Cutout * When carry ing out maintenance on the E 5GN, only the t erminal pl ate c an be drawn out wit h the t erminal leads s till attached. 24 3 (48 number of units -2.5) 60 min. 60 min. +1.0 0 45 22 +0.3 0 +0.6 0 22 +0.3 0 Mounted Separately • Insert t he Controller through the hole in t he panel[...]

  • Page 8

    E5GN E5GN Installation MOUNTI NG 1. Insert the E5GN into the mounting hole in t he panel f rom the front. 2. Push the adapter along t he E5GN body from the terminals up to the panel, and secure i t tem porarily . 3. Tighten the two fixi ng screws on the adapter . When tight en- ing sc rews, tighten t he two screws alternately (keeping the torque to[...]

  • Page 9

    E5GN E5GN Operation INITIA L SE TUP On previous Controllers , s ensor input type, alarm t ype and control period were set on DIP swit ches. These hardware setti ngs are now set i n parameters in s etup menus . The and keys are used to swit ch bet ween set up menus, and the amount of time that y ou hold t he key s down determines which setup m enu y[...]

  • Page 10

    E5GN E5GN 2. PID Control Using Auto-tuning • Changing Param eters indicates that there is a parameter . K eep on pressing the mode key until the de- sired parameter is selected. • Changing Set V alues Use the or keys to change the set value displayed in the setup menu. Displa y E5CN E5GN No. 1 display No. 2 display No. 1 display No. 2 display I[...]

  • Page 11

    E5GN E5GN Specification Setting After T urning ON Power OUTLINE O F OPERA TI ON PRO CEDURES Key Operation In the following descript ions, all the parameters are introduced in the display sequence. Some paramet ers m ay not be display ed depending on t he protec t set tings and operation conditions . Note: 1. Of thes e lev els, the init ial s etting[...]

  • Page 12

    E5GN E5GN Protect Level T o sel ect t his l evel, simult aneously press the and keys for at least one second. This l evel i s to prevent unwant ed or accident al modificat ion of parameters. Protected levels will not be display ed, and s o the parameters in that level c annot be modified. Communications Setting Level T o select this le vel, press t[...]

  • Page 13

    E5GN E5GN SPECIFICA TI ON SETTI NG (AFTER TURNI NG O N POW ER) Initial Setting Level This l evel is used for sett ing bas ic s pecifi cations of t he T emperature Controller . Using t his l evel, set t he input type f or select ing the input t o be connec ted s uch as the t hermocouple or platinum resist ance t hermometer and set t he range of set [...]

  • Page 14

    E5GN E5GN INPUT TYPE Using a Thermocouple Input T ype When using a thermoc ouple input type, follow t he spec ific ations listed in the following table. Input t ype Specif icati ons S et V alue Input T emperature Range Thermocouple K 0 - - 200 t o 1300 ( ° C) / - - 300 t o 2300 ( ° F) 1 - - 20.0 to 500.0 ( ° C) /0.0 to 900.0 ( ° F) J 2 - - 100 [...]

  • Page 15

    E5GN E5GN ALARM 1 AND ALARM 2 For the al arm 1 and alarm 2, select alarm t ypes out of t he 12 alarm types list ed in the foll owing table. Set V alue Alarm T ype Alarm O utput Operat ion y When X i s pos itive When X is negative 0 Alarm f unction OFF Output OFF 1 *1 Upper- and lower-li mit (deviation) *2 2 Upper-limit (deviati on) 3 Lower-limit (d[...]

  • Page 16

    E5GN E5GN P ARAMETERS Parameters related to set ting it ems for each level are marked in boxes in the f lowcharts and brief descript ions are given as required. A t the end of eac h set ting i tem, press t he mode k ey t o return to the beginni ng of eac h level . Display E5CN E5G N No. 1 display No. 2 display No. 1 display No. 2 display Password i[...]

  • Page 17

    E5GN E5GN Initial Setting Level Input type Scaling upper limi t Decimal point T emperature unit Set point upper limit PID / ON/OFF Standard/heating and cooling ST Control period (heat) Alarm 1 type Move to advanced function setting level Set the pulse output cycle. Direct/reverse operation Alarm 2 type Limit the set point. Select the control system[...]

  • Page 18

    E5GN E5GN Protect Level Operation/adjustment protection Restricts display and modification of menus in the operation and adjustment levels. Initial setting/communications protecti on Restricts display and modification of menus in the initial setting, operation level and adjustment levels. Setting change protection Protects changes to setups by oper[...]

  • Page 19

    E5GN E5GN Communications Setting Level Set the E5CN/E5GN comm unicati ons speci ficat ions in the communicat ions set ting level. For sett ing communi cations paramet ers, use the E5CN/E5GN panel. The communic ations parameters and their s etti ngs are l isted in the following t able. Parame ter Display ed charac ters S et (moni tor) val ue Set v a[...]

  • Page 20

    E5GN E5GN TROU BLE SHOOT ING When an error oc curs, an error c ode will be display ed on t he No. 1 display . Check the c ontents of an error and tak e appropriate countermeas ures. No. 1 display T ype of error Countermeasures Input error Check the wiri ng of i nputs f or mis wiring, disconnect ions, short-c ircuit s, and the input type. Memory err[...]

  • Page 21

    E5GN E5GN Precautions OPER A TING ENV IRONME NT • Use the T emperature Controller wit hin the rated operating temperature, storage temperature, and operating humidity specif ied for each model . • Use the T emperature Controller acc ording t o the perf or- mance spec ific ations s uch as vibrat ion, s hock, and degree of protecti on spec ified [...]

  • Page 22

    E5GN E5GN Cat. No. GCTC12 1/99 Spec ific ations subject to c hange without notice. Printed in U.S. A. OMRON ELECTRONICS, INC. O n eE a s t C o m m e r c eD r i v e Schaumburg, IL 60173 1- 80 0- 55- OM RO N OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M 1B 5V 8 416-286-6465[...]