Omnitron Systems Technology 8000-0 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omnitron Systems Technology 8000-0, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omnitron Systems Technology 8000-0 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omnitron Systems Technology 8000-0. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omnitron Systems Technology 8000-0 should contain:
- informations concerning technical data of Omnitron Systems Technology 8000-0
- name of the manufacturer and a year of construction of the Omnitron Systems Technology 8000-0 item
- rules of operation, control and maintenance of the Omnitron Systems Technology 8000-0 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omnitron Systems Technology 8000-0 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omnitron Systems Technology 8000-0, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omnitron Systems Technology service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omnitron Systems Technology 8000-0.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omnitron Systems Technology 8000-0 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    iConverter ® Network Management Module USER MANUAL Release 3.4[...]

  • Page 2

    Page 2 T able of Contents 1.0 Overview .................................................................................................................... 3 2.0 Port S tructure ............................................................................................................. 4 2.1 Overview ...............................................[...]

  • Page 3

    1.0 OVERVIEW The iConverter ® Network Management Module (NMM) is the heart of the iConverter management system. It features a 32-bit, high performance RISC microprocessor executing a realtime operating system. It supports the SNMP and T elnet protocols and is capable of controlling up to 19 managed chassis. The NMM delivers Operations, Administrat[...]

  • Page 4

    2.0 PORT STRUCTURE 2.1 OVERVIEW The Network Management Module front panel provides the access to the Management ports. Management can be accessed through the serial port or the UTP port. The module features a backplane Ethernet port for connectivity to adjacent modules. Serial Port Daisy Chain Port UTP Management Port 2.1.1 Serial Console Port The [...]

  • Page 5

    The illustration below shows how multi-chassis are managed using Omnitron’ s NetOutlook Management Software. From the chassis view screen, each of the chassis are available. NetOutlook Chassis V iew Multi-chassis configuration can also be managed through the serial console port. From the Chassis Selection section of screen, each of the chassis co[...]

  • Page 6

    The iConverter 19-Module, 5-Module and 2-Module Chassis backplanes provide ethernet data connectivity between adjacent slots. The A and B backplane ports connect the slots as illustrated. AA A AA AA AA A AA A AA AA AA BB BBB BBB BB B BBB BBB BB 1 2 3 4 5 6789 1 0 11 1 2 13 14 15 16 17 18 19 “A” Data bus “B” Data bus 19-Module Chassis A B 12[...]

  • Page 7

    The backplane data bus supports Out-of-Band Management and In-Band Management configurations. Out-of-Band Management Out-of-Band Management is available by directly connecting the Network Management Station (NMS) to the UTP port on the front of the NMM. This isolates the management traf fic from the rest of the traffic in the chassis. Chassis Backp[...]

  • Page 8

    3.0 INST ALLA TION PROCEDURE 3.1 OVERVIEW The following steps outline the installation and configuration procedures for the NMM. Refer to the specified sections for detailed instructions. • Configuring Switches (Section 3.2) • Installing the Module and Connecting the UTP Cable (Section 3.3) • Configure the Module via Command Line Interface (S[...]

  • Page 9

    3.4 CONFIGURE THE MODULE VIA COMMAND LINE INTERF ACE T o configure, attach the NMM to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperT erminal. Using a standard serial cable, connect the serial port of the PC and the Serial Console Port of the NMM. This is a standard asynchronous DCE serial interface. The pin[...]

  • Page 10

    The Management Options screen will be displayed. Management Options iConverter, Serial Agent Network Management 1: Chassis and Module Management 2: Set Module Identifier Management Module Preferences 3: IP and Control Preferences 4: SNMP Preferences 5: Abandon Preference Changes 6: Save Preference Changes 7: Restore to Factory Defaults 8: Restart M[...]

  • Page 11

    3.4.1 Setting IP and Control Preferences An IP address is required for the SNMP or T elnet access. The factory default setting is 192.168.1.220. The IP address can be configured manually or automatically as a DHCP client. 3.4.1.1 Setting IP Parameters Manually T o manually configure the IP address and control parameters, select 3 from the Managemen[...]

  • Page 12

    3.4.1.2 Setting IP Parameters as DHCP Client T o configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The Other Networking Features screen will appear . Management Options iConverter, Serial Agent Network Management 1: Chassis and Module Management 2: Set Module Identifier Management Module Preferences 3: IP[...]

  • Page 13

    T o set the Chassis Name, select 5 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis name. IP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.255.255.0 3: Set Gateway 192.168.1.1 4: Chassis Number 1 5: Chassis Name (also sysName) NMM [...]

  • Page 14

    3.4.2 Setting SNMP Preferences T o set the SNMP Preferences for the NMM, select 4 from the Management Options screen, press < ENTER > to enter the SNMP Preferences screen. SNMP Preferences Screen iConverter, Serial Agent Chassis Number = 1 SNMP Engine ID 80001CAE03000687003B19 1: sysContact Omnitron (949) 250-6510 2: sysLocation Irvine, CA US[...]

  • Page 15

    Page 15 The module supports the three levels of Authentication and Encryption (Security Levels) for User 1 and User 2; noAuthNoPriv , authNoPriv and authPriv . noAuthNoPriv uses username for authentication, authNoPriv provides authentication based on the HMAC-MD5 algorithm and authPriv provides DES 56-bit encryption based on the HMAC-MD5 algorithm.[...]

  • Page 16

    3.4.3 Management Support 3.4.3.1 VLAN The NMM Management Processor can independently transmit and receive Management Data with an IEEE 802.1Q tag. T o enable and configure this feature, type 9 from the Management Options screen to access the Other Networking Features screen. Other Networking Features Screen iConverter, Serial Agent 1: Enable/Disabl[...]

  • Page 17

    switch settings, then the module’ s hardware settings take effect. T o set the Soft-switch Reload function, select 8 at the IP and Control Preferences screen, press < ENTER > and then follow the screen prompts to change the setting. IP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.255[...]

  • Page 18

    Page 18 3.4.5 Access the NMM Remotely Remote access to the NMM is provided via SNMP , T elnet, FTP or an external serial modem connected to the Serial Console Port. 3.4.5.1 Accessing the NMM via NetOutlook (SNMP) The NMM can be remotely accessed by SNMP-client software such as Omnitron’ s NetOutlook SNMP Management Software or third-party SNMP ma[...]

  • Page 19

    IP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.255.255.0 3: Set Gateway 192.168.1.1 4: Chassis Number 1 5: Chassis Name (also sysName) NMM 6: Enable/Disable TELNET Enabled 7: Enable/Disable FTP Disabled 8: Enable/Disable Soft Switch Reload Disabled 9: TELNET Password ***** 10: FTP Password [...]

  • Page 20

    Page 20 3.4.5.4 Up dating the NMM Firmware via FTP Using an FTP application, upload the new firmware into the FTP root directory of the NMM. When the file transfer is complete, the NMM verifies the file and then automatically restarts with the newly loaded firmware. For detailed instructions on updating the management modules and other modules in t[...]

  • Page 21

    4.0 MODULE ST A TUS 4.1 OVERVIEW The Module status screen provide information on the NMM. The Module status screen is accessible by selecting the module slot number from the Chassis V iew screen. T o access the Module status screen, select 1 at the Management Options screen, press < ENTER >. The Chassis Selection screen will be displayed. Fro[...]

  • Page 22

    Module - iConverter NMM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8000-0 Serial Number = xxxxxxxx Manufacturing Date = xxxxxxxx Hardware Revision = xx Software Revision = xx LED 1: Power = On 2: Power Supply 1 = Off 3: Power Supply 2 = On 4: Power Supply 3 = Off 5: Master(on)/Slave = On 6: Mgmt Activity[...]

  • Page 23

    5.0 NMM SPECIFICA TIONS Prot ocol s I P , UD P , S NMP v 1 , S NMP v2c, S NMP v 3 , TC P , AR P , I C M P , T el n et , FT P , 802. 3ah Copper Connect ors R J -4 5 , D B -9 Contr ol s UTP C r o s s o v e r , F ro n tp la ne /B a c k p la ne LED Di spl a ys Pw r , Pw r Su p pl y ( 3) , M an age m en t Lin k, Ma s te r /S la ve, Mg t P o ll Support e[...]

  • Page 24

    6.0 TROUBLESHOOTING GUIDE 6.1 OVERVIEW The NMM module has several LED indicators available to assist in the determination of problems. Refer to Section 3.5, V erify Operation, for LED definitions. 6.1.1 Power Issues Problem: The Power LED does not illuminate after installation is complete or no LED indicators ar e ON Possible Causes: A. Confirm tha[...]

  • Page 25

    7. 0 WARRANTY This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. T O REGISTER, COMPLETE AND MAIL OR F AX T[...]