Omega OS643W manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omega OS643W, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega OS643W one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omega OS643W. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omega OS643W should contain:
- informations concerning technical data of Omega OS643W
- name of the manufacturer and a year of construction of the Omega OS643W item
- rules of operation, control and maintenance of the Omega OS643W item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega OS643W alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega OS643W, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega OS643W.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega OS643W item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OMEGA OS643W Infrared Thermometer[...]

  • Page 2

    OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com For immediate technical or application assistance: USA and Canada: Mexico and Latin America: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA SM Tel: (95) 800-TC-OMEGA SM Customer Service: 1-800-622-2378 / 1-800-622-BEST SM FAX: (95) 203-359-7807 Engineering Service: 1-80[...]

  • Page 3

    1 INTRODUCTION This instrument is a portable easy use 3½ digit, compact-sized digital thermometer designed to use infrared or K-type thermocouple as input. Meter with Backlit LCD, Auto-hold function and auto power off (15 seconds approx.) feature after releasing MEAS button to extend battery life and with analog signal output function. Temperature[...]

  • Page 4

    2 WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. The symbol on the instrument indicates that the operator must refer to an explanation in this manual.[...]

  • Page 5

    3 CAUTION • Do not use the unit near any device which generates strong electromag- netic radiation or near a static electrical charge, as these may cause errors. • Do not point the lens at the sun or at any other source of strong light. If you do, the sensor may be damaged. • Do not contact the lens against the object whose temperature is to [...]

  • Page 6

    4 SPECIFICATIONS GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999. Overrange : (OL) or (-OL) is displayed. Low battery indication: the " " is displayed when the battery voltage drops below the operating level. Measurement rate: 2.5 times per second, nominal. Operating Environment: 32°F to 122°F (0°C [...]

  • Page 7

    5 Infrared Radiation ELECTRICAL Temperature Range: 0°F to 500°F, -20°C to 260°C. Display Resolution: 1°F / 1°C. Accuracy: ±3% of reading or ±6°F/3°C, whichever is greater @ 64.4 to 82.4°F (@ 18 to 28°C) ambient operating temperature. Temperature Coefficient: ±0.2% of reading or ±0.36°F/0.2°C, whichever is greater, change in accuracy[...]

  • Page 8

    6 Spot size increases with distance from the probe tip as shown[...]

  • Page 9

    7 K-type thermocouple ELECTRICAL Temperature Range: -58°F to 1999°F, -50°C to 1300°C. Display Resolution: 1°F / 1°C. Accuracy: Accuracy is specified for operating temperatures over the range of 64°F to 83°F (18°C to 28°C), for 1 year, not including thermocouple error. ±(0.3% rdg + 2°F) -58°F to 1999°F ±(0.3% rdg + 1°C) -50°C to 100[...]

  • Page 10

    8 OPERATING INSTRUCTIONS MEAS (MEASURE) Button Depress MEAS button to turn on the meter for measuring temperature. Releasing MEAS button to stop measuring temperature and automatically hold the display reading, the meter turns off automatically after 15 seconds.[...]

  • Page 11

    OPERATION Infrared Radiation Measurements 1. When the power is off, pressing the MEAS button turns on the power. 2. Use "IR / K" switch to select IR Temperature function. 3. Use " " switch to turn on or turn off the display Back-Light. 4. Use "°F/°C" switch to select °F or °C the Temperature Range. 5. Point the len[...]

  • Page 12

    10 K-type thermocouple Measurements 1. When the power is off, pressing the MEAS button turns on the power. 2. Use "IR / K" switch to select K Temperature function. 3. Use " " switch to turn on or turn off the display Back-Light. 4. Use "°F/°C" switch to select °F or °C the Temperature Range. 5. Connect a type K the[...]

  • Page 13

    11 MEASUREMENT CONSIDERATIONS 1. Theory of Measurement Every object emits infrared energy in accordance with its temperature. By measuring the amount of this radiant energy, it is possible to determine the temperature of the emitting object. 2. About Infrared Infrared radiation is a form of energy (electromagnetic radiation), and has the property t[...]

  • Page 14

    12 4. Emissivity All objects emit invisible infrared energy. The amount of energy emitted is proportional to the object's temperature and its ability to emit IR energy. This ability, called emissivity, is based upon the material that the object is made of and its surface finish. Emissivity values range from 0.10 for a very reflective object to[...]

  • Page 15

    13 MAINTENANCE Battery Replacement Power is supplied by four 1.5V (AAA size) batteries. The " " appears on the LCD display when replacement is needed. To replace the batteries, remove the screw from the back of the meter and lift off the battery cover case. Remove the batteries from battery contacts. Cleaning Periodically wipe the case wi[...]

  • Page 16

    Substance Thermal Substance Thermal emissivity emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Lather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 W ater 0.92 to 0.96 Lacquer (matt) 0.97 I c e 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0[...]

  • Page 17

    W ARRANTY OMEGA warrants this unit to be free of def ects in materials and workmanship and to give satisfactory ser vice for a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month g race per iod to the nor mal one (1) year pr oduct warranty to cov er handling and shipping time . This ensures that OMEGA's [...]

  • Page 18

    It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply . OMEGA is constantly pursuing cer tification of its products to the European New Approach Directives . OMEGA will add the CE mark to ev er y appropr iate device upon certification. The information contained in this document is believ ed to be correct b[...]

  • Page 19

    Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! HEATERS þ Heating Cable þ Cartridge & Strip Heaters þ Immersion & Band Heaters þ Flexible Heaters þ Laboratory Heaters PRESSURE/STRAIN AND FORCE þ Transducers & Strain Gauges þ Load Cells & Pressure Gauges þ Displacement Transducers þ [...]