Omega CCT-05 Series manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omega CCT-05 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega CCT-05 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omega CCT-05 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omega CCT-05 Series should contain:
- informations concerning technical data of Omega CCT-05 Series
- name of the manufacturer and a year of construction of the Omega CCT-05 Series item
- rules of operation, control and maintenance of the Omega CCT-05 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega CCT-05 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega CCT-05 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega CCT-05 Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega CCT-05 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    M2216/1201 http://www.omega.com e-mail: info@omega.com ® U ser ’ s Guide CCT -05 Frequency Input Signal Conditioners[...]

  • Page 2

    Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com For immediate technical or application assistance: USA and Canada: Sales Service:[...]

  • Page 3

    NOTES T ABLE OF CONTENTS PAGE Open the Housing . . . . . . . . . . . . . . . . . . . . . . . . 3 Internal Overview . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Supply module MA . . . . . . . . . . . . . . . . . . 4 Changing the Power Supply . . . . . . . . . . . . . . . . 4 Signal Output module MS . . . . . . . . . . . . . . . . . . 5 Ch[...]

  • Page 4

    MECHANICAL DIMENSIONS 75 mm (2.952") 110 mm (4.33") 36 mm (1.417") 45 mm (1.771") OUTPUT S / SALI DAS m A Vdc INPU T / ENTR A D A S U PP L Y / AL IME N T ACI ON 3 4 5 6 9 10 1 1 12 7 1 + Lo H i + -- TECHNICAL DATA WEIGHT . . . . . . . . . . . . . . . . . . . 270 g. HOUSING BASE . . . . . . . . . . . . Polycarbonate, RAL 7032, UL[...]

  • Page 5

    SIGNAL OUTPUT Current SIGNAL OUTPUT Voltage Sensor NAMUR CONNECTIONS + OUTPUTS / SALIDA S mA V dc INPUT / ENTRA DA SUPPL Y / ALIM ENT ACIO N 3 4 5 6 9 10 1 1 1 2 7 1 + Lo H i + -- POWER SUPPLY The side label, shows the type and value of the power supply. SIGNAL OUTPUT Voltage OUTPUTS / SALIDA S mA Vdc INPUT / ENTRA DA SUPPL Y / ALIM ENT ACIO N 3 4 [...]

  • Page 6

    3 2 1 4 5 6 7 9 8 10 PT1 Fine gain adjust PT2 Trigger adjust SELECTOR A FIG. 8 The frequency ranges are interpreted as follow : Range A (0 to 40/70 Hz.) which means that the minimum range is from 0 to 40 Hz, and the maximum range from 0 to 70 Hz. The high level of the signal output can be adjusted for any value between 40 to 70 Hz. SELECTOR B SIGNA[...]

  • Page 7

    INPUT SIGNAL TYPE PNP, NPN, Namur, Vac FREQUENCY Min. 10 Hz. Max. 40 KHz. AUXILIARY POWER SUPPLY +24 Vdc @ 25 mA. for PNP, NPN. 8.2 Vdc for Namur OUTPUT 0 to 20 mA or 4 to 20 mA R L < 600 Ω max. 22 mA ±3% 0 to 10 Vdc R L > 1000 Ω max. 11 V ±3% ACCURACY ≤ 0.2 % FS RESPONSE TIME ≤ 250 mS GALVANIC ISOLATION Input, Output and Power Supp[...]

  • Page 8

    INPUT SIGNAL TYPE PNP, NPN, Namur, Vac FREQUENCY Min. 10 Hz. Max. 40 KHz. AUXILIARY POWER SUPPLY +24 Vdc @ 25 mA. for PNP, NPN. 8.2 Vdc for Namur OUTPUT 0 to 20 mA or 4 to 20 mA R L < 600 Ω max. 22 mA ±3% 0 to 10 Vdc R L > 1000 Ω max. 11 V ±3% ACCURACY ≤ 0.2 % FS RESPONSE TIME ≤ 250 mS GALVANIC ISOLATION Input, Output and Power Supp[...]

  • Page 9

    3 2 1 4 5 6 7 9 8 10 PT1 Fine gain adjust PT2 Trigger adjust SELECTOR A FIG. 8 The frequency ranges are interpreted as follow : Range A (0 to 40/70 Hz.) which means that the minimum range is from 0 to 40 Hz, and the maximum range from 0 to 70 Hz. The high level of the signal output can be adjusted for any value between 40 to 70 Hz. SELECTOR B SIGNA[...]

  • Page 10

    SIGNAL OUTPUT Current SIGNAL OUTPUT Voltage Sensor NAMUR CONNECTIONS + OUTPUTS / SALIDA S mA V dc INPUT / ENTRA DA SUPPL Y / ALIM ENT ACIO N 3 4 5 6 9 10 1 1 1 2 7 1 + Lo H i + -- POWER SUPPLY The side label, shows the type and value of the power supply. SIGNAL OUTPUT Voltage OUTPUTS / SALIDA S mA Vdc INPUT / ENTRA DA SUPPL Y / ALIM ENT ACIO N 3 4 [...]

  • Page 11

    MECHANICAL DIMENSIONS 75 mm (2.952") 110 mm (4.33") 36 mm (1.417") 45 mm (1.771") OUTPUT S / SALI DAS m A Vdc INPU T / ENTRAD A S U PP L Y / A L IMEN T AC I ON 3 4 5 6 9 10 1 1 12 7 1 + Lo H i + -- TECHNICAL DATA WEIGHT . . . . . . . . . . . . . . . . . . . 270 g. HOUSING BASE . . . . . . . . . . . . Polycarbonate, RAL 7032, UL [...]

  • Page 12

    NOTES T ABLE OF CONTENTS PAGE Open the Housing . . . . . . . . . . . . . . . . . . . . . . . . 3 Internal Overview . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Supply module MA . . . . . . . . . . . . . . . . . . 4 Changing the Power Supply . . . . . . . . . . . . . . . . 4 Signal Output module MS . . . . . . . . . . . . . . . . . . 5 Ch[...]

  • Page 13

    WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers recei[...]

  • Page 14

    Where Do I Find Everything I Need for Process Measurement and Control? OM EGA…Of Course! TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers & Process Monitors M U Infrared Pyrometers PR[...]