Omega Speaker Systems HX93DA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omega Speaker Systems HX93DA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega Speaker Systems HX93DA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omega Speaker Systems HX93DA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omega Speaker Systems HX93DA should contain:
- informations concerning technical data of Omega Speaker Systems HX93DA
- name of the manufacturer and a year of construction of the Omega Speaker Systems HX93DA item
- rules of operation, control and maintenance of the Omega Speaker Systems HX93DA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega Speaker Systems HX93DA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega Speaker Systems HX93DA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega Speaker Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega Speaker Systems HX93DA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega Speaker Systems HX93DA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    www .omega.com e-mail: info@omega.com U ser ’ s Guide HX93A, HX93DA SERIES RH/T emperature T ransmitter MADE IN Shop online at[...]

  • Page 2

    Servicing Nor th America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Ser[...]

  • Page 3

    TABLE OF CONTENTS HX93A, HX93DA SERIES RH/Temperature Transmitter i Section Page 1. General Description .................................................................... 1 2. Unpacking .................................................................................... 1 3. Theory of Operation ....................................................[...]

  • Page 4

    FIGURES HX93A, HX93DA SERIES RM/Temperature Transmitter ii Figure Page Figure 1 Basic Transmitter Set-up With Current Loop Output .............................................. 2 Figure 2 Wall Mount Model Dimensions ...................................... 3 Figure 3 Duct Mount And Remote Probe Model Dimensions .......................................[...]

  • Page 5

    1 HX93A, HX93DA SERIES RH/Temperature Transmitter 1 1. General Description The OMEGA ® HX93A and HX93DA Series Relative Humidity/ Temperature Transmitter’s provide a linearized and temperature compensated output signal of 4 to 20 mA or 0 to 1 Vdc depending upon the model selected for both relative humidity and temperature measurement. The output[...]

  • Page 6

    2 HX15AV-W Wall mount “High Ambient Temperature” application RH/Temperature transmitter (dual 0 to 1 Vdc Output) HX15AC-W Wall mount “High Ambient Temperature” application RH/Temperature transmitter (dual 4 to 20 mA Output) HX15AV-D Duct mount “High Ambient Temperature” application RH/Temperature transmitter (dual 0 to 1 Vdc Output) HX1[...]

  • Page 7

    3 Complimentary Instruments Power Supply, OMEGA ® Part No.: PSU-93 Csi32 Series Panel Meters and Controllers Recommended Accessories Shielded Transmitter Cable, OMEGA ® Part No.: TX4-100 (100 ft) RH Calibration Kit, OMEGA ® Part No.: HX92-CAL 4. Mounting OMEGA’s HX93A and HX93DA transmitter’s are designed for either wall, duct or remote prob[...]

  • Page 8

    4 5. Electrical Connections All electrical connections and wiring should be performed by a suitably trained professional only. Models: HX93AC, HX93AC-D, HX93AC-RP1, HX93DAC, HX93DAC- D,HX93DAC-RPI (Current Output) TB1 - Relative Humidity TB2 - Temperature 1. + Power Supply 1. + Power Supply 2. No Connection 2. No Connection 3. 4-20 mA Output 3. 4-2[...]

  • Page 9

    5 Models: HX93AV, HX93AV-D HX93AV-RP1 (Voltage Output) TB1 - Relative Humidity TB2 - Temperature 1. + Power Supply 1. + Power Supply 2. + Output 2. + Output 3. - Power Supply 3. - Power Supply 7. Voltage Transmitter Wiring Examples For voltage output models (0 to 1 Vdc) Figure 5 - Voltage Transmitter Wiring Example 8. Relative Humidity Output Calcu[...]

  • Page 10

    6 9. RH Measured Vs Output Reading 10. Temperature Output Calculations To calculate Temperature by measuring the current or voltage output use the following formulas. For Current output in ºC (-20 to 75ºC) ºC = (Output measured in miliamps – 4) ÷ .1684 - 20 = ºC EXAMPLE: (12.0 mA – 4) ÷ .1684 - 20 = 27.5ºC For Current output ºF (-4 to 1[...]

  • Page 11

    7 11. Calibration Your transmitter has been factory calibrated to meet or exceed the specifications outlined in this manual. To maintain original specifications it is generally recommended that your transmitter be re- calibrated on an annual basis depending on operating conditions. 12. Calibration Procedure for HX93AC (all styles) Relative Humidity[...]

  • Page 12

    8 13. Calibration Procedure for HX93AC (all styles) Temperature Adjustment Recommended equipment: • RTD Simulator OMEGA ® Model No.: CL510-1 • Handheld Digital Multi-meter, OMEGA ® Model No.: HHM29 • Dc Power Supply, OMEGA ® Model No.: PSU-93 1. Remove enclosure cover 2. Connect the power supply and multimeter as shown in the figure below.[...]

  • Page 13

    9 14. Calibration Procedure for HX93AV (all styles) Relative Humidity Adjustment Recommended equipment: • Humidity Calibration Kit, OMEGA ® Model No.: HX92-CAL • Handheld Digital Multi-meter, OMEGA ® Model No.: HHM29B • Dc Power Supply, OMEGA ® Model No.: PSU-93 1. Remove enclosure cover. 2. Connect transmitter as shown in figure below. 3.[...]

  • Page 14

    10 15. Calibration Procedure for HX93AV (all Styles) Temperature Adjustment Recommended equipment: • 100 Ohm RTD Simulator OMEGA ® Model No.: CL510-1 • Handheld Digital Multi-meter, OMEGA ® Model No.: HHM29 • Dc Power Supply, OMEGA ® Model No.: PSU-93 1. Remove enclosure cover 2. Connect the power supply and multimeter as shown in the figu[...]

  • Page 15

    11 15A. Display Scaling for HX93DAC (all styles) Your HX93DA transmitter comes with dual built-in LCD indicators for displaying both Humidity and Temperature. Before the meter adjustment or re-scaling can be done the transmitters current output should be checked as per the calibration procedure in Section 12 and 13 to verify the display will be adj[...]

  • Page 16

    HX93A, HX93DA SERIES RH/Temperature Transmitter 15A 12 Temperature Display Scaling Recommended equipment: • RTD Simulator OMEGA ® Model No.: CL510-1 • Handheld Digital Multi-meter, OMEGA ® Model No.: HHM29 • Dc Power Supply, OMEGA ® Model No.: PSU-93 For ºF Display 1. Remove enclosure cover 2. Connect the power supply and multimeter as sh[...]

  • Page 17

    13 16. Maintenance If your Humidity transmitter will be used in a dusty environment, the protective sensor filter, if clogged, may be removed for cleaning. Unscrew the protective cover and gently blow compressed air through the filter screen. A soft brush may also be used to remove dirt particles from the screen. If the sensor is subjected to 100% [...]

  • Page 18

    14 Max Loop Resistance: Ohms = (V supply – 6 V)/.02 A Sensor Type: 100 Ohm Platinum RT 18. General Specifications Enclosure Housing: Gray Polycarbonate, (IP 65, DIN 40050) NEMA rated up to 13, UL Listed. Connections Cable Strain Relief: Nylon, Liquid-tight with neoprene gland for 2.29 to 6.73 mm (.09 to .265") diameter cable. Wire Connection[...]

  • Page 19

    WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers r[...]

  • Page 20

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, Controllers [...]