Nimbus Water Systems MN-800-TF manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Nimbus Water Systems MN-800-TF, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Nimbus Water Systems MN-800-TF one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Nimbus Water Systems MN-800-TF. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Nimbus Water Systems MN-800-TF should contain:
- informations concerning technical data of Nimbus Water Systems MN-800-TF
- name of the manufacturer and a year of construction of the Nimbus Water Systems MN-800-TF item
- rules of operation, control and maintenance of the Nimbus Water Systems MN-800-TF item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Nimbus Water Systems MN-800-TF alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Nimbus Water Systems MN-800-TF, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Nimbus Water Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Nimbus Water Systems MN-800-TF.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Nimbus Water Systems MN-800-TF item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MN-800-TF REVERSE OSMOSIS TREATMENT SYSTEM OWNERS MANUA L Nimbus W ater Systems 41840 McAlby Court, Suite A Murrieta, CA 92562-7036 800-451-9343[...]

  • Page 2

    2 THE NIMBUS M N-800 TF REVERSE OSMOSIS TREATMENT SYSTEM TABLE OF CONTENT S §1.0 MN -800 TF SYSTEM SPECIFICATIONS .......................................................................... 3 §2.0 SYSTEM COM PONENTS (See Figure 1) .......................................................................... 3 §3.0 PRE-INSTALLATION PROCEDURES........[...]

  • Page 3

    3 THE NIMBUS M N-800 TF REVERSE OSMOSIS TREATMENT SYSTEM The Nimbus MN-800 TF is the per fect system f or a wide variety of applicat ions. Features include stainless steel pressur e vessels, fram e and concentrate r ecirculation valve. There ar e pressure gaug es on the pre- filt er outlet , post-f ilter inlet and the hig h pressure outlet of t he [...]

  • Page 4

    4[...]

  • Page 5

    5 CONCENTRAT E RECIRCULAT ION VALVE: A needle valve that controls t he amount of concentrate fr om t he desalinator arr ay to be recirculat ed back into t he feed st ream. T his f eature allows for hig her recovery rates. Addit ionally, adjustment of t his valve regulates the pum p discharge pressur e. FLOW CONTRO L: A f ixed orifice that controls [...]

  • Page 6

    6 ANCILLARY EQUI PMENT: The f ollowing items are also covered in this m anual to f orm a com plete water treat ment system. PRESSURE TANK: T he tank pr ovides storag e f or approximat ely 34 gallons of treated water at a pressure of 40 to 60 psi. REMOTE BY-PASS PANEL: This panel monit ors tr eated water TDS and st orage t ank pressur e. It includes[...]

  • Page 7

    7 §3.0 PRE-INSTA LLA TION PROCEDURES PLEASE READ CAREFULLY. FAI LURE TO FOLLOW T HESE PROCEDURES CAN RESULT I N DAMAGE TO YO UR SYSTEM AND VOID YO UR W ARRANTY. §3.1 PA CKA GING Upon delivery, inspect packag ing f or damag e and report it to your carrier at that time. After unpacking the system, inspect it caref ully f or sig ns of dam age. All d[...]

  • Page 8

    8 §4.0 INSTA LLAT ION PLEASE READ CAREFULLY BEFORE BEGI NNING I NSTALLAT ION. FAILURE TO FOLLOW THESE PROCEDURES CAN RESULT I N DAMAGE TO YOUR SYSTEM AND VOI D YOUR W ARRANTY. §4.1 LOCAT ION It is recom mended that systems be locat ed where they are protected f rom harsh environments such as r ain, snow and extreme temperat ures (bot h hot and co[...]

  • Page 9

    9[...]

  • Page 10

    10 piece of black 5/8” t ubing f rom t he valve up to the 5/8” compression fitt ing at the back right side of t he RO system manif old. §4.2.2 BY-PASS PA NEL PREPA RA TIO N AND INSTA LLA TIO N : The by-pass panel is to be located convenient t o the RO where the T DS monitor is visible and the valve can be operated without diff iculty. The stan[...]

  • Page 11

    11[...]

  • Page 12

    12 §5.0 SYSTEM FLUSH A ND PERFORMANCE VERIFICA TIO N Although MN-800-TF system s are fully test ed at the f actory prior t o shipping, it is recommended t o flush and verify your system's perf orm ance on-site. §5.1 SYSTEM FLUSH AND O PERATI O N New membranes have a preservative on them that needs to be f lushed bef ore use. • Open the f a[...]

  • Page 13

    13 • As a f inal check turn on the city water valve to the By-Pass Panel and check the plum bing for leak s. §5.2 PERFORM ANCE VERI F I CATI O N Factory test data is supplied with the system. To ensure optim um perf ormance, on-site data should be taken and com pared to the f actor y test data. T his data should be tak en aft er the system has b[...]

  • Page 14

    14 gauge r eads about 60 psi (4. 1 bar). Now, by opening the t ank inlet valve the tank pressure should begin to drop and t he system should turn on when the pressure drops below about 40 psi (2.8 bar). I f the system fails t o shut of f at 60 psi (4.1 bar), watch the gauge and be sure that it does not rise above 80 psi ( 5.5 bar). If it reaches 80[...]

  • Page 15

    15 psi (1 .4 bar). • Befor e servicing, always disconnect power to the unit to avoid shock. • To adjust , remove cover and ref er to the diag ram inside t he cover. • Turn adjustment nut #1 count erclockwise to decrease cut -out pressure and clock wise to increase cut- out pr essure. Under nor mal circumst ances it is not necessary to adj ust[...]

  • Page 16

    16 • Tag and disconnect the three t ubing connections on the desalinat or namely the f eed, concentrate and product . • Unsnap the desalinator r etainers and pull desalinator (s) out . • Remove retaining clips f rom ends of desalinator by tapping the open ends of the clips with a plastic or r awhide mallet until t hey are through t he slots i[...]

  • Page 17

    17[...]

  • Page 18

    18 • Since the membr ane is new it will need to be f lushed and tested. Follow procedures outlined in §5.0 SYST EM FLUSH AND PERFORMANCE VERIFICATIO N. §7.4 PRE FILTER CA RBON CA RTRIDGE REPLA CEMENT • Befor e servicing, always disconnect power to the unit to avoid shock. • Close feed water and t ank valves. • Activate the switch on the s[...]

  • Page 19

    19 • Inspect sump f or crack s. Replace as necessary. • Lubricate O- ring with an appropriat e petroleum or silicone-based lubricant. Install O-ring into i ts seat in sump . • Install new carbon cartr idge with the white rubber ring up. • Replace sump by screwing it onto cap in a count er-clock wise direction (as viewed from top). A wrench [...]

  • Page 20

    20 §8.0 PA RTS A ND ACCESSORIES ITEM PART N UMBER DESCRIPT ION MOT ORS & PUMPS 102612 Motor, ¾ HP 101168 Clam p, V Band 101199 Pump , 165 gph, Brass DESALINAT ORS, MEMBRANES & 104459 Des alinator, T F, Com plete (MN-800 T F & MN-800 T F) HOUSINGS 100716 Mem brane, AG 2525 (High Rejec tion) 104167 Pressur e Vesse l, Stainless Steel 104[...]

  • Page 21

    21 §9.0 A TTA CHMENTS §9.1 REMO TE BYPA SS SYSTEM INSTRUCTIONS Indication – W hen water is requir ed even though RO pr oduct water of the desired q uality is not available. This unit allows f or the supply of feed water t o supplement the RO water requir ement. Installation – See the diag ram below f or plumbing the system. As a m inimum, use[...]

  • Page 22

    22 §9.2 TDS MONITOR I NSTRUCTIONS Model TDS-2B TDS Monitor Part # 100860 The Nimbus T DS-2B TDS Monitor is desig ned to operat e within the Remote Bypass Unit of the Nimbus MN system. It is installed inside t he upper lef t corner of the Bypass Unit f rame and is connected to a tee f itting installed in the pr oduct water output line. The Monitor [...]

  • Page 23

    23 §9.3 WA RRA NTY Nimbus Wat er Systems Limited One Year Warra nty Commercial and Industr ial Sys tems The Nimbus W ater S ystem s (Nim bus) Lim ited W arranty extends to the original purchas er of the s ystem . This warranty covers all pa rts and factory labor needed t o repair any Nimbus -supplied item that proves to be defec tive m aterial, wo[...]

  • Page 24

    24[...]