A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of NETGEAR GS524T, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of NETGEAR GS524T one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of NETGEAR GS524T. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of NETGEAR GS524T should contain:
- informations concerning technical data of NETGEAR GS524T
- name of the manufacturer and a year of construction of the NETGEAR GS524T item
- rules of operation, control and maintenance of the NETGEAR GS524T item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of NETGEAR GS524T alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of NETGEAR GS524T, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the NETGEAR service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of NETGEAR GS524T.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the NETGEAR GS524T item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    R Copper Gigabit Switch Inst allation Guide 24 PORT 10/1 00/1 000 Mbps GS 524 T MODEL[...]

  • Page 2

    ii © 2002 by N ETGEAR, Inc. All rights rese r ved. T rademarks N ETGEAR ® is a reg istered trademar k of NETG EAR, Inc. in the Un ited States and other Countries. All other tr ademarks and reg is tered trademarks are the pr operty of their perspec tive owners. Statement of Conditions In the inte res t of impro vin g inter nal design, operati onal[...]

  • Page 3

    iii F ederal Communications Commission (FCC) Compliance Notice: Radio F requency Notice T his device compl ies with par t 15 of the FCC Rules. Oper ation is subject to the follo wing two conditi ons: • T his device may not cause harmful i nterference. • T his device must accept any interfe rence received, includi ng inte rference that may cause[...]

  • Page 4

    iv Customer Support F or assis tance with installing and conf ig urin g your N ETGEAR system or with questions or pr oblems follo wing i ns tallation: • Check the N ETGEAR Web page at http://www .NETG EAR.com. • Call T echnical Support at the phone number listed on the Support Informati on Card that shipped with your switch. • Email T echn ic[...]

  • Page 5

    contents v CONTENTS CHAPTER 1 Introduction Features 1-1 P ackage Contents 1-2 CHAPTER 2 Physical Description F ront P anel 2-1 RJ-45 2-2 A u to-upl ink TM 2-2 LEDs 2-4 Rear P ane l 2-4 CHAPTER 3 Applications Desktop Switchi ng 3-1 Segment Switchi ng and Bri dg ing fr om 10 Mbps or 100 Mbps to 1000 Mbps 3-2 CHAPTER 4 Installation Prepari ng the Site[...]

  • Page 6

    contents vi APPENDIX A T echnical Specif ications A-1 APPENDIX B Connector Pin Assignments RJ-45 Plug and RJ-45 Connector B-1 APPENDIX C Cab ling Guidelines Usin g 1000BASE-T Gig abit Ethernet o ver Categ or y 5 Cable C-1 Overview C-1 Cabl in g C-1 Length C-1 Return Loss C-2 Near End Cross T alk (N EXT) C-2 P atch Cab les C-3 Conclusi ons C-3 F ast[...]

  • Page 7

    contents vii FIGURES Fi gure 1-1. Model GS524T Switch P ackage Contents 1-2 Fi gure 2-1. F ront P anel of the Model GS524T Switch 2-1 Fi gure 2-2. Rear P ane l of the Mod el GS524T Switch 2-2 Fi gure 2-3. W arn ing! Creati ng loops disab les your networ k (Example 1) 2-3 Fi gure 2-4. W arn ing! Creati ng loops disab les your networ k (Example 2) 2-[...]

  • Page 8

    contents viii T ABLES T ab le 2-1. LED Descripti ons 2-4 T ab le 4-1. Oper ating En vir onment Requirements 4-1 T ab le 5-1. T r oubleshootin g Infor mation 5-1 T ab le B-1. 10/100/1000 Mbps RJ-45 Plug and RJ-45 Connector Pin Assi gnments B-2 T ab le C-1. Electrical Requirements of Category 5 Cable C-4[...]

  • Page 9

    intr oduc tion 1-1 CHAPTER 1: INTR ODUCTION T he N ETGEAR Mode l GS524T 24-P or t Copper Gig abit Switch pro vi des you with a low-cost, hi gh-perf ormance network soluti on and is d esigned to anchor and i ntercon- nect 10/100/1000 megabits per second (Mbps) wor kgroups usi ng copper Gi gabit l inks. F eatures T he Model GS524T switch has the f ol[...]

  • Page 10

    intr oduc tion 1-2 Package Contents Fi gure 1-1 i llustrates the Model GS524T switch package contents. Figure 1-1. Model GS524T Switch Package Contents V er ify that your package contai ns the follo wing: • Model GS524T switch • Rubber f ootpads f or tabletop installati on • T he Ins tallation Gui d e • Rack mount kit f or 19-inch rack i ns[...]

  • Page 11

    physical descripti on 2-1 CHAPTER 2: PHYSIC AL DESCRIPTION T his chapte r d escribes the hardware features of the N ETGEAR Mode l GS524T Copper Gi gabit Switch. F ront Panel T he front pane l of the Mod el GS524T switch contains the f ollowi ng LEDs that cor re- spond to each network port: FDX/COL (full-duple x/coll ision), Ac tivity(RX/TX)/10Mbps [...]

  • Page 12

    physical descripti on 2-2 RJ-45 P orts T he Model GS524T switch has 24 auto-s ensing 10/100/1000 Mbps UTP ports. Each por t can operate at 1000 Mbps full-duple x mod e, 100 Mbps full/half duple x mode, or 10Mbps full/half duple x mode, and pro vi de a s tandard UTP for Categ or y 5 or Category 5e cable. Fi gure 2-2 sho ws a RJ-45 connec tor . F or [...]

  • Page 13

    physical descripti on 2-3 Note: Usin g Auto Upl ink to create multiple active paths between any two network devices can cause undesirab le loops in the network, resultin g in an endless broadcast traff ic that disab les your networ k. Loops occur when there are alte rnate r ou tes between two network dev ices. In Fi g ure 2-3, f or e xample, a loop[...]

  • Page 14

    physical descripti on 2-4 100-240 VAC 50-60 Hz AC po wer Receptacle F ans LEDs T ab le 2-1 d escribes the activity of the LEDs. T able 2-1. LED Descriptions Label Color Activity Descripti on P owe r Green On P owe r is supplied to the switch. Off P owe r is disconnected. FDX/COL Green On T he por t is operati ng in full-duple x mode. Off T he por t[...]

  • Page 15

    applicati ons 3-1 CHAPTER 3: APPLICA TIONS T his chapte r pres ents an ove r view of the topolog ies possible by i ncorporati ng the N ETG EAR Mod el GS524T Copper Gi gabit Switch i nto y our network. Desktop Switching Fi gure 3-1 i llustrates the Model GS524T switch, used as a d esktop switch to buil d a powe rful network that enab les us ers to h[...]

  • Page 16

    applicati ons 3-2 Segment Switching and Bridging from 10 Mbps or 100 Mbps to 1000 Mbps T he Model GS524T switch, as illustrated i n Fi gure 3-2, connec ts multiple power workg roups and servers usi ng hi gh-speed g i gabit l inks. Each power wor kgr oup is anchored by a N ETG EAR Mod el FS518T switch. Other workg roups are connected by a N ETG EAR [...]

  • Page 17

    installation 4-1 CHAPTER 4: INSTALLA TION T his chapte r d escribes the installati on procedures f or the N ETGEAR Mode l GS524T Copper Gi gabit Switch. Preparing the Site Bef ore you beg i n installi ng your switch, prepare the installati on site. Mak e sure your oper ating en vir onment meets the operati ng env ironment requirements of the equip-[...]

  • Page 18

    installation 4-2 • T he Ins tallation Gui d e • Suppor t Infor mation Card Installing the Switch on a Flat Surface T o i ns tall the switch on a f lat surface, be sure to attach the rubber f ootpads to the bottom of the switch. Installing the Switch in a Rack Refer to F ig ure 4-1 w hen installi ng the switch in a r ack. Figure 4-1. Attaching M[...]

  • Page 19

    installation 4-3 Refer to F ig ure 4-2 w hen connec ting the switch. Figure 4-2. Connecting to the Model GS524T Switch V erifying Installation When powe r has been applied to the switch, ver ify that: • T he green po wer LED on the front pane l is on. • T he green l ink LED on each connected por t is on. When the switch is connected and operati[...]

  • Page 20

    CHAPTER 5: TR OUBLESHOOTING T his chapte r pro vides i nfor mation about troub leshooting the N ETG EAR Model GS524T Copper Gi gabit Switch. T able 5-1 l is ts symptoms, causes, and solu tions of possible pr oblems. T able 5-1. T roub leshooting Information Symptom Cause Solution P owe r LED is off . No powe r is received Check the po wer cord conn[...]

  • Page 21

    troub leshooting 5-2 Network Adapter Cards Make sure the networ k adapter cards i ns talled in the PCs are i n workin g conditi on and the software dri ver has been i ns talled. Conf iguration If prob lems occur after alte rin g the network conf ig urati on, restore the ori g inal con- nections and deter mi ne the problem by i mplementin g the new [...]

  • Page 22

    technical spec ificati ons A-1 APPENDIX A: TECHNICAL SPECIFICA TIONS T his append ix pro vides techn ical specif icati ons for the N ETG EAR Model GS524T Copper Gi gabit Switch. Network Protocol and Standards Compatibility IEEE 802.3ab 1000BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3i 10BASE-T IEEE 802.3x f low contr ol Data Coding 1000 Mbps with P AM5[...]

  • Page 23

    technical spec ificati ons A-2 Interface RJ-45 Connector s for 10BASE-T Ethe rnet, 100BASE-TX F as t Ethernet, and 1000BASE-T Gi gabit Ether net P ower Consumption 75 W Heat Radiation: 34.9812 Btu/hr Acoustic Noise: 50.2dB Input V oltage (Po wer Adapter) 100 – 240 V AC Physical Specif ications Di mensions: 13.0 x 1.7 x 8.0 i n.; 33.0 x 4.3 x 20.7[...]

  • Page 24

    technical spec ificati ons A-3 Safety Agency Appro vals UL Listed (UL 1950), cUL TUV Licensed (EN 60 950)[...]

  • Page 25

    connector pin assignments B-1 APPENDIX B: CONNECTOR PIN ASSIGNMENTS T his append ix pro vides i nfor mation about the RJ-45 plug and the RJ-45 connector used for the N ETG EAR Model GS524T Coppe r Gig abit Switch. RJ-45 Plug and RJ-45 Connector It is i mpor tant that all 1000 BASE-T cer tified Categ or y 5 or Category 5e cabl ing use RJ-45 plugs. T[...]

  • Page 26

    connector pin assignments B-2 T able B-1 l is ts the pin assignments f or the 10/100/1000Mbps RJ-45 plug and the RJ-45 connector . T able B-1. 10/100/1000 Mbps RJ-45 Plug and RJ-45 Connector Pin Assignments Pin Channe l Descr iption 1 A Rx/Tx Data + 2 Rx/Tx Data - 3 B Rx/Tx Data + 6 Rx/Tx Data - 4 C Rx/Tx Data + 5 Rx/Tx Data - 7 D Rx/Tx Data + 8 Rx[...]

  • Page 27

    cabl ing g uidel ines C-1 APPENDIX C: CABLING GUIDELINES T his append ix pro vides spec ificati ons f or cables used with the N ETGEAR Mode l GS524T Copper Gi gabit Switch. Using 1000BASE-T Gigabit Ethernet o ver Categ ory 5 Cable Overvie w When usin g the 1000BASE-T s tandard, the l im itations of cab le installations and the steps necessar y to e[...]

  • Page 28

    cabl ing g uidel ines C-2 Return Loss Return loss measures the amount of ref lected signal ene rgy resulti ng from i mpedance changes i n the cabl ing l ink. T he nature of 1000BASE-T rend ers this measurement very i mpor tant; if too much energ y is ref lec ted back on to the receive r , the device wi ll not perf orm opti mally . All f our pair s [...]

  • Page 29

    cabl ing g uidel ines C-3 Patch Cab les When install ing y our equipment, replace ol d patch panel cab les that do not meet Category 5e specif icati ons. As po inted out in the N EXT sec tion, this near end piece of cable is cr itical for successful ope rati on. Conclusions F or optimum pe rfor mance of your 1000BASE-T pr oduc t, it is i mpor tant [...]

  • Page 30

    cabl ing g uidel ines C-4 Categ ory 5 Cable Category 5 distributed cable that meets ANSI/EIA/TIA-568-A bui ld ing wir ing standards can be a max imum of 328 feet (ft) or 100 mete r s (m) in length, d ivide d as f ollows: • 20 ft (6 m) between the hub or switch and the patch panel (if used) • 295 ft (90 m) from the wir ing closet to the wall out[...]

  • Page 31

    cabl ing g uidel ines C-5 Tx Rx 1 2 3 6 Tx Rx 1 2 3 6 A B B B 1 2 3 6 1 2 3 6 Tx Rx Tx Rx T wisted Pair Cables f or 100 BASE-TX F or two devices to commun icate, the transm itter of each device must be connec ted to the receive r of the other device. T he crosso ver function is usuall y implemented inte rnall y as par t of the circuitry in the dev [...]

  • Page 32

    cabl ing g uidel ines C-6 Patch Panels and Cab les If y ou are using patch pane ls, make sure that they meet the 100BASE-TX require- ments. NETG EAR recommends Categ or y 5e UTP cable f or all patch cables and work area cab les to ensure that your UTP patch cab le rati ng meets or e xceeds the distributi on cable rati ng. T o wire patch pane ls, y [...]

  • Page 33

    cabl ing g uidel ines C-7[...]

  • Page 34

    R NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA Phone: 1-888-NETGEAR www .NETGEAR.com M-GS524TNA-0[...]