National Instruments NI 9403 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments NI 9403, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments NI 9403 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of National Instruments NI 9403. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of National Instruments NI 9403 should contain:
- informations concerning technical data of National Instruments NI 9403
- name of the manufacturer and a year of construction of the National Instruments NI 9403 item
- rules of operation, control and maintenance of the National Instruments NI 9403 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments NI 9403 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments NI 9403, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments NI 9403.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments NI 9403 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OPERATING INSTRUCTIONS AND S PECIFICATIONS NI 9403 32-Channel, TTL D igital Input/Output Module ni.com/manuals Deutsch Français[...]

  • Page 2

    NI 9403 Operating I nstruction s and Specificati ons 2 ni.com This doc u ment describes ho w to u se the National Instr u ments 9 403 and incl u des specif ications and pin assignments for the NI 9403. Vi s i t ni.com/info and enter rd s oftwarever s ion to determine which software yo u need for the mod u les yo u are u sing. For information abo u [...]

  • Page 3

    © National Inst ruments Corp. 3 NI 9403 Operating Instructi ons and Specific ations Safety Guidelines Operate the NI 9403 only as described in these operating instr u ctions. Hot Surface This icon denotes that the component may be hot. T o u ching this component may res u lt in bodily inj u ry . Safety Guidelines fo r Hazardous Loca tions The NI 9[...]

  • Page 4

    NI 9403 Operating I nstruction s and Specificati ons 4 ni.com Caution S u bstit u tion of components may impair s u itability for Class I, Division 2. Caution For Zone 2 applications, install the system in an enclos u re rated to at least IP 54 as defined b y IEC 60529 an d EN 60529 . Caution For Zone 2 applications, connected signals m u st be wit[...]

  • Page 5

    © National Inst ruments Corp. 5 NI 9403 Operating Instructi ons and Specific ations Special Conditions fo r Marine Appli cations Some mod u les are Lloyd’ s Re gister (LR) T ype Approv ed for marine applications. T o verify Llo yd’ s Register cert ification, visit ni.com/certification and search for the LR certificate, or look for the Lloyd’[...]

  • Page 6

    NI 9403 Operating I nstruction s and Specificati ons 6 ni.com Connecting the NI 9403 The NI 9403 has a 37-pin DSUB connector that pro vides connections for th e 32 digital inp u t/o u tp u t channels. Figure 1. NI 9403 Pin Assignm ents DIO16 DIO17 DIO18 DIO19 DIO20 DIO21 DIO22 DIO23 COM COM DIO24 DIO25 DIO26 DIO27 DIO28 DIO29 DIO30 DIO31 DIO0 DIO1 [...]

  • Page 7

    © National Inst ruments Corp. 7 NI 9403 Operating Instructi ons and Specific ations Each channel has a DIO pin to which yo u can connect a digital inp u t or o u tp u t de vice. The 32 DIO channels are internally referenced to COM, so yo u can u se any of the fo u r CO M lines as a reference for the external signal. Yo u can independently config u[...]

  • Page 8

    NI 9403 Operating I nstruction s and Specificati ons 8 ni.com Refer to Fig u re 2 for an ill u stration of sev eral types of digital de vices connected to the NI 9403. Figure 2. Connecting Digital Devices to the NI 9403 TTL Signal +5 V +5 V LED DIO0 as Input DIO1 as Input COM DIO2 as Output NI 9403 Dev 3 Dev 2 Dev 1[...]

  • Page 9

    © National Inst ruments Corp. 9 NI 9403 Operating Instructi ons and Specific ations Overcurrent/Short-Circuit Protection The ov erc u rren t protection allo ws only a specified amo u nt of c u rrent thro u gh the o u tp u t channels to protect the NI 940 3 from short circ u its. If the NI 9403 goes into an o verc u rrent state, the mod u le sets a[...]

  • Page 10

    NI 9403 Operating I nstruction s and Specificati ons 10 ni.com ni.com/info and enter c s erie s doc for information abo u t C Series doc u mentation. T ypically , when a system is in sleep mode, yo u cannot comm u nicate with the mod u les. In sleep mode, the system cons u mes minimal po wer and may diss ipat e less heat than it does in normal mode[...]

  • Page 11

    © National Inst ruments Corp. 11 NI 9403 Operating Instructi ons and Specific ations Digital logic le v els Inp u t V oltage .......... ......... ........... ... – 0.25 to 5.25 V High, V IH ....... ........... ........... . 2.2 V min Low , V IL ..... ............ ......... ..... 0.8 V max Hysteresis, V H .......... ........... . 0.2 V min O u tp[...]

  • Page 12

    NI 9403 Operating I nstruction s and Specificati ons 12 ni.com Ti m i n g Inp u t Set u p time 1 .......... ............ ..... 10 ns min Hold time 2 ......... ......... .......... 60 ns min O u tp u t Propagation delay 3 ............... 330 ns max Channel-to-channel ske w 4 ... 265 ns max 1 Setup time is the a mo u nt of time inp u t signals m u st[...]

  • Page 13

    © National Inst ruments Corp. 13 NI 9403 Operating Instructi ons and Specific ations Update/transfer time 1 cRIO-9151 R Series Expansion chassis . ........ ....... 8 μ S max All other chassis ........... ........ 7 μ S max Direction change time 1 ...... ......... 18 μ S max Overv oltage protection Channel-to-COM .. ........... ............ ....[...]

  • Page 14

    NI 9403 Operating I nstruction s and Specificati ons 14 ni.com MTBF .......... ........... ............ ........... ... 763,325 ho u rs at 25 °C; Bellcore Iss u e 2, Method 1, Case 3, Limited P art Stress Method Note Contact NI for Bellcore MTBF specifications at other temperat u res or for MIL-HDBK-21 7F specifications. Power Requirements Power c[...]

  • Page 15

    © National Inst ruments Corp. 15 NI 9403 Operating Instructi ons and Specific ations Safety Safety Voltages Connect only v oltages that are within the follo wing lim its. Channel-to-COM .. ........... ............ ..... ±30 V max on u p to 8 channels at a time, Meas u rement Category I Isolation Channel-to-channel ........ ............ None Chann[...]

  • Page 16

    NI 9403 Operating I nstruction s and Specificati ons 16 ni.com eq u ipment, limited-ene rg y parts of eq u ipment , circ u its po wered by reg u lated lo w-v oltage so u rces, and electronics. Caution Do not connect the NI 9403 to signals or u se for meas u rements within Meas u rement Categories II, III, or IV . Safety Standards This prod u ct is [...]

  • Page 17

    © National Inst ruments Corp. 17 NI 9403 Operating Instructi ons and Specific ations Hazardous Locations U.S. (UL) ........ ........... ........... ......... ... Class I, Division 2, Gro u ps A, B, C, D, T4; Class I, Zone 2, AEx nA IIC T4 Canada (C-UL) ............ ........... .......... Class I, Division 2, Gro u ps A, B, C, D, T4; Class I, Zone [...]

  • Page 18

    NI 9403 Operating I nstruction s and Specificati ons 18 ni.com Operating h u midity (IEC 60068-2-56)....... ........... ............ 10 to 90% RH, noncondensing Storage h u midity (IEC 60068-2-56)....... ........... ............ 5 to 95% RH, noncondensing Maxim u m altit u de.......... ......... .......... 2,000 m Poll u tion Degree (IEC 60664) ...[...]

  • Page 19

    © National Inst ruments Corp. 19 NI 9403 Operating Instructi ons and Specific ations Electromagnetic Compatibility This prod u ct is designed to meet the req u ire ments of the follo wing standards of EMC for electrical eq u ipment for meas u remen t, control, and laboratory u se: • EN 61326 EMC req u irements; Ind u strial Imm u nity • EN 550[...]

  • Page 20

    NI 9403 Operating I nstruction s and Specificati ons 20 ni.com ni.com/certification , search by mod u le n u mber or prod u ct line, and click the appropriate link in the Certification col u mn. Environmental Mana gement National Instr u ments is committe d to designing and man u fact u ring prod u cts in an en vironmentally res ponsible manner . N[...]

  • Page 21

    © National Inst ruments Corp. 21 NI 9403 Operating Instructions and Specific ations Where to Go for Support The National Instr u ments W eb site is yo u r complete reso u rce for technical s u pport. At ni.com/ s upport yo u have access to ev erything from tro u bleshooting and applic ation de velopment self-help reso u rces to email and phone ass[...]

  • Page 22

    NI 9403 Operating I nstructions and Specifications 22 ni .com telephone s u pport o u tside the United Stat es, contact yo u r local branch off ice: A u stralia 1800 300 800, A u stria 43 662 457990-0, Belgi u m 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, Czech Rep u blic 420 224 235 774, Denmark 45 45 76 [...]

  • Page 23

    © 2007–2008 Nati onal Instruments Corp. All rights reserved. 374069E-01 Jun08 National Instruments, NI, n i.com, and LabVIEW are trademarks of National Instruments C orporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. O ther product and company names ment ioned herein are trad[...]