National Instruments NI 2590/2591 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments NI 2590/2591, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments NI 2590/2591 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of National Instruments NI 2590/2591. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of National Instruments NI 2590/2591 should contain:
- informations concerning technical data of National Instruments NI 2590/2591
- name of the manufacturer and a year of construction of the National Instruments NI 2590/2591 item
- rules of operation, control and maintenance of the National Instruments NI 2590/2591 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments NI 2590/2591 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments NI 2590/2591, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments NI 2590/2591.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments NI 2590/2591 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Computer-Based Instruments NI 2590/2591 User Manual NI 2590/2591 User Manual November 2000 Edition Part Number 322387 B-01[...]

  • Page 2

    Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide Offices Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011, Canada (Calgary) 403 274 9391, Canada (Ottawa) 613 233 5949, [...]

  • Page 3

    Important Information Warranty The NI 2590 and NI 2591 switch modules and accessories are war rante d ag ains t de fec ts i n ma ter ials and wo rkman ship fo r a period of on e year from the date of s hipment, as e videnced by rec eipts or ot her docume ntation. Nat ional Instru ments will, at its option, repair or replace equipment that proves to[...]

  • Page 4

    Compliance FCC/Canada Radio Frequency Interference Compliance* Determining FCC Class The Federal Communication s Commission (FCC) has rules to protect wireless comm unications from interference. The FCC places digital electronics into two classes. These classes ar e known as Class A (for use in industrial- commercial locations only) or Class B (for[...]

  • Page 5

    • Connect the equipment into an outlet on a circuit diffe rent from that to which the rec eiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Canadian Depart ment of Communications This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil n[...]

  • Page 6

    Conventions The follo wing con ventions are used in this manual: < > Angle brackets that contain numbers separated by an ellipsis represent a range of values associated with a bit or signal name — for e xample, DBIO<3..0>. This icon denotes a note, which alerts you t o important information. This icon denotes a caution, which advi ses[...]

  • Page 7

    © National Instruments Corporatio n vii NI 2590/2591 User Manual Contents Chapter 1 Routing Signals with Your NI 2590/2591 About the NI 2590/2591 ................................................................................................ 1-1 Triggers................ .......................... ...................... .......................... [...]

  • Page 8

    Contents NI 2590/259 1 User Man ual viii ni.com Appendix C Common Questions Appendix D Technical Support Resources Glossary Index[...]

  • Page 9

    © National Instruments Corporatio n 1-1 NI 2590/2591 User Manual 1 Routing Signals with Y our NI 2590/2591 This manual describes the electrical and mechanical characteristics of the NI 2590, a 1 × 4, 50 Ω , 1.3 GHz multiplexer module, and the NI 2591, a1 × 4, 50 Ω , 4.0 GHz multiplexer module, for the PXI bus. It contains information concern[...]

  • Page 10

    Chapter 1 Routing Signals with Y our NI 2590/2591 NI 2590/259 1 User Man ual 1-2 ni.com The external trigger input trigger is generated by another instrument or by software and causes the NI 2590/2591 to advance to the next entry in the scan list. The trigger s can be routed to any of the PXI TTL tr iggers or to the P X Is t a rt r i g g e r . Refe[...]

  • Page 11

    Chapter 1 Ro uting Signals with Y our N I 2590/2591 © National Instruments Corporatio n 1-3 NI 2590/2591 User Manual Connecting Signals The front of the NI 25 90 module has five “ push-on ” SMB connectors for signal connections. The NI 2591 has five SMA female connectors. The center connection, labeled COM, is connected in a through path to on[...]

  • Page 12

    Chapter 1 Routing Signals with Y our NI 2590/2591 NI 2590/259 1 User Man ual 1-4 ni.com NI 2591 Front Connector The following diagram shows the NI 2591 front connect or. Table 1-1 describes the connector sign als. Figure 1-2. NI 2591 Front Connector Table 1-1. Front Connector Signal Description Signal Name Ty p e Description CH<0..3> Input/Ou[...]

  • Page 13

    Chapter 1 Ro uting Signals with Y our N I 2590/2591 © National Instruments Corporatio n 1-5 NI 2590/2591 User Manual Software Choices You have several options to choose from when programming your National Instruments switch modul e. You can use the NI-SWITCH driv er software or National Instruments appl ication software. NI-SWITCH Driver Software [...]

  • Page 14

    Chapter 1 Routing Signals with Y our NI 2590/2591 NI 2590/259 1 User Man ual 1-6 ni.com Third-Party Software The NI-SWITCH instrum ent driver also includes support files for Microsoft Visual C++ and Microsoft Visual Basic. See the NI-SWITCH Software Readme File for version support information. Cabling and Accessor y Requirements National Instrument[...]

  • Page 15

    © National Instruments Corporatio n 2-1 NI 2590/2591 User Manual 2 NI 2590/2591 Operation This chapter contains safety instructions and a fu nctional overview of the NI 2590/2591 switch modules. It also explains the operation of each functional unit making u p the switch modu le. Safety Instructions Cautions Do not operate dam aged equipm ent. The[...]

  • Page 16

    Chapter 2 NI 2590/2591 Operation NI 2590/259 1 User Man ual 2-2 ni.com Functional Over view The following block diagrams illustrate the key functi onal components of the NI 2590 and NI 2591 switch modu les. The major components of th e NI 2590/2591 are as follo ws: • General-purpose high-frequency relays • Switch control cir cuitry • Random s[...]

  • Page 17

    Chapter 2 NI 2590/2591 Operation © National Instruments Corporatio n 2-3 NI 2590/2591 User Manual Figure 2-1. NI 2590 Module Block Diagram CH1 COM CH2 CH0 CH3 F ront Panel T r iggers Scan Memory MUX23 MUX0123 MUX01 Relay Control PXI Interface PXIbus Connector[...]

  • Page 18

    Chapter 2 NI 2590/2591 Operation NI 2590/259 1 User Man ual 2-4 ni.com Figure 2-2. NI 2591 Module Block Diagram CH1 COM CH2 CH0 CH3 T r iggers PXI Bus Connector High– F requency Relay 4 GHz Relay Module Control Lines Relay Control Scan Memory PXI Interface DECODER F ront Panel[...]

  • Page 19

    Chapter 2 NI 2590/2591 Operation © National Instruments Corporatio n 2-5 NI 2590/2591 User Manual Relay Operation NI 2590 Operation The NI 2590 has four channels, CH0 through CH3, any on e of which can be connected to the single commo n channel (COM) by closing the appropriate relays. Y ou can control the relays individually , or you can use highe[...]

  • Page 20

    Chapter 2 NI 2590/2591 Operation NI 2590/259 1 User Man ual 2-6 ni.com Switch Control Circuitr y The switch control circuitr y (SCC) is responsible for opening and closin g relays on the NI 2590/259 1. You can load commands for the SCC into scan memory using the driver software you received with your kit. Consult the online help or your soft ware d[...]

  • Page 21

    Chapter 2 NI 2590/2591 Operation © National Instruments Corporatio n 2-7 NI 2590/2591 User Manual intervention. Y ou can configure the switch module to process the scan list once or to continuously loop throu gh the scan list. PXI Interface You can configure and control your NI 2 590/2591 switch module through the PXI interface, taking adv antage [...]

  • Page 22

    Chapter 2 NI 2590/2591 Operation NI 2590/259 1 User Man ual 2-8 ni.com Modes SCANADV has two modes o f operation. In its default m ode, the SCANADV trigger asserts for 1 µs after the relay h as debounced. You can also configure the swit ch module for handshaking mod e, in which the SCANADV trigger goes high after a relay settles, and the SCANADV t[...]

  • Page 23

    Chapter 2 NI 2590/2591 Operation © National Instruments Corporatio n 2-9 NI 2590/2591 User Manual it possible to wir e external triggers from/to only one switch module in th e system, which simplifies the wiring scheme. Note The NI 2590/2591 does not support triggers on the front p anel connector . If the trigger signal is external to the chassis,[...]

  • Page 24

    © National Instruments Corporatio n A- 1 NI 2590/2591 User Manual A Specifications This appendix lists the specifications for the NI 2590/25 91 switch module. These specif i cations are typical at 25 ° C unless otherwise note d. NI 2590 Input Characteristics Number of relays .................. .................. 3 Common-mode voltage Channel to e[...]

  • Page 25

    Appendix A Specifications for NI 2590 NI 2590/259 1 User Man ual A-2 ni.com VSWR at: < 100 MHz ............. ......................... . < 1.15 < 500 MHz ............. ......................... . < 1.35 < 1.3 GHz ........ .......................... ...... < 1.5 Isolation: < 500 MHz ............. ......................... . <[...]

  • Page 26

    Appendix A Specifications for NI 2590 © National Instruments Corporatio n A- 3 NI 2590/2591 User Manual PXI T rigger Bus Trigger lines ........... ....................... ......... 8 Star trigger................. ...................... ....... 1 Power Requirement +5 VDC Minimum (all relays opened) .......... 350 mA Maximum (all relays closed) . ..[...]

  • Page 27

    Appendix A Specifications for NI 2591 NI 2590/259 1 User Man ual A-4 ni.com NI 2591 Input Characteristics Number of relays ....... .............. ...............3 Common-mode voltage Channel to earth......................... ...... 30 V rms or DC Maximum switching voltag e AC............ ...................... ..................30 V rms DC.........[...]

  • Page 28

    Appendix A Specifications for NI 2591 © National Instruments Corporatio n A- 5 NI 2590/2591 User Manual Note Refer to the safety information in Chapter 2, NI 2590/2591 Operation , for important information about using your N I 2591 with high-power signals. Dynamic Characteristics Relay operate time (at 20 ° C) Typical .................. .........[...]

  • Page 29

    Appendix A Specifications for NI 2591 NI 2590/259 1 User Man ual A-6 ni.com Electromagnetic compatibilit y (EMC) emissions ......................... .... Refer to the document supplied with the chassis for compliance to relevant directives. EMI .......... ......................... ...............FCC Class A compliant Maximum altitude ..............[...]

  • Page 30

    © National Instruments Corporatio n B- 1 NI 2590/2591 User Manual B Ser vicing Y our Module This appendix describes proced ures for servicing your NI 2590/25 91 module. Replacing the NI 2590 Relay Module The NI 2590 is constructed so that the relay module can be replaced when the relays fail. The life of the relay i s nominally 10 5 operations whe[...]

  • Page 31

    Appendix B Servicing Y our Module NI 2590/259 1 User Man ual B-2 ni.com Follo w these in structions to replace the failed module as shown in Figure B-1. 1. Ground yourself with a grounding strap o r a ground connected to your PXI chassis. Properly groundi ng yourself prev e nts damage to your PXI module f rom electrostatic discharge. 2. Remov e the[...]

  • Page 32

    Appendix B Servicing Y our Module © National Instruments Corporatio n B- 3 NI 2590/2591 User Manual Figure B-2. RF 2591 Replacement Relay Module Follo w these in structions to replace the failed module as shown in Figure B-2. 1. Ground yourself with a g rounding strap or a grou nd connected to your PXI chassis. Properly grounding yourself pre vent[...]

  • Page 33

    © National Instruments Corporatio n C- 1 NI 2590/2591 User Manual C Common Questions This appendix addresses common questions you may hav e while using your NI 2590/2591 switch module. What should I do if the software detects the module but the switches do not switch? V erify that the switches do not switch. Close your application program and then[...]

  • Page 34

    Appendix C Common Questions NI 2590/259 1 User Man ual C-2 ni.com Finally , verify that your code is correct. For reference, see the examples described in the NI-SWITCH Software User M anual . The NI-Swi tch dri ver also ships with sev eral examples in source code. Compare your algorithm to the ones in the examples. Do I need to program the switch [...]

  • Page 35

    © National Instruments Corporatio n D-1 NI 2590/2591 User Manual D T echnical Support Resources W eb Support National Instruments W eb support is your first stop for help in solving installation, configuration, and application pro blems and questions. O nline problem-solving and di agnostic resources include frequ ently asked questions, knowledge [...]

  • Page 36

    Appendix D T echnical Support Resources NI 2590/259 1 User Man ual D-2 ni.com W orldwide Support National Instruments has of fices located around the world to help address your support needs. Y ou can access our branch of fice W eb sites from the W orldwide Of fices section of ni.com . Branch off ice W eb sites provide up-to-date contact informatio[...]

  • Page 37

    © National Instruments Corporatio n G-1 NI 2590/2591 User Manual Glossar y Pref ix Meaning V alue p- pico- 10 – 12 n- nano- 10 – 9 µ- micro- 10 – 6 m- milli- 10 – 3 M- mega- 10 6 G- giga- 10 9 Numbers and Symbols ° degrees Ω ohms % percent > greater than < less than A A amperes A C alternating current ADC amperes direct current A[...]

  • Page 38

    Glossary NI 2590/259 1 User Man ual G-2 ni.com B breakpoint a specified point in program cod e where the program pau ses to perform some action; a breakpoint interrupt can be add ed to a scan list for debugging or o ther special needs. bus the group of conductors that in terconnect individual circuitry in a computer . T ypically , a bus is the expa[...]

  • Page 39

    Glossary © National Instruments Corporatio n G-3 NI 2590/2591 User Manual F flyback voltage the voltage spike generated the instant current stops flo wi ng through an inductor H handshaking the use of two trigger lines between two instruments, such as a switch and a DMM, to synchronize th eir actions Hz hertz — the number of scans read or update[...]

  • Page 40

    Glossary NI 2590/259 1 User Man ual G-4 ni.com R random scanning scanning the channels in a mux in any order reflecti ve switch a switch architecture in which the unused channels are NO T terminated in the characteristic impedance of the syst em. The unused channels are open circuits. relay a switch that connects or disconnects the si gnal to a com[...]

  • Page 41

    Glossary © National Instruments Corporatio n G-5 NI 2590/2591 User Manual V V volts v aristor an electrical resistor whose resistance depends on the applied v oltage VDC volts, direct current VI virtual instrument — (1) a combination of hardware and/or softw are elements, typically used with a PC, that has the functionality of a classic stand-al[...]

  • Page 42

    © National Instruments Corporatio n I-1 NI 2590/2591 User Manual Index B block diagrams NI 2590, 2-3 NI 2591, 2-4 C cables and accessories, 1-6 certification and comp liances NI 2590, A-3 NI 2591, A-6 CH<0..3> signal (table), 1-4 COM signal (table), 1-4 common questions ab out NI 2590/25 91, C - 1t oC - 2 connectors front connector NI 2590 ([...]

  • Page 43

    Index NI 2590/259 1 User Man ual I-2 ni.com contact protection, 1-2 front connectors (figur es), 1-3 to 1-4 overview, 1-1 parts locator diagram NI 2590, B-1 NI 2591, B-3 replacing relay module NI 2590, B-1 to B-2 NI 2591, B-2 to B-3 RF switching precautions, 1-2 s e r v i c i n g ,B - 1t oB - 3 software choices, 1-5 to 1-6 triggers, 1-1 to 1-2 NI D[...]

  • Page 44

    Index © National Instruments Corporatio n I-3 NI 2590/2591 User Manual S safety instructions, 2-1 scanner advanced trigger modes of operation, 2-8 overview, 1-1 purpose and use, 2-7 scanning common questions, C-1 to C-2 initiating, 2-8 random scanning, 2-6 to 2-7 servicing the NI 2590/25 91, B-1 to B-3 parts locator diagram NI 2590, B-1 NI 2591, B[...]