National Instruments CFP-20XX manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments CFP-20XX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments CFP-20XX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of National Instruments CFP-20XX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of National Instruments CFP-20XX should contain:
- informations concerning technical data of National Instruments CFP-20XX
- name of the manufacturer and a year of construction of the National Instruments CFP-20XX item
- rules of operation, control and maintenance of the National Instruments CFP-20XX item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments CFP-20XX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments CFP-20XX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments CFP-20XX.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments CFP-20XX item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    FieldPoint TM cFP-20 xx Quick Start Guide What Y ou Need to Get Set Up • cFP-20 xx LabVIEW RT controller • Mounting hardware (DIN rail, panel- mount, or rack-mount accessory) • I/O module(s) • Connectivity accessories: connector blocks, cables • 11–30 V power supply • Accessories: Ethernet cable, screwdriver • PC running Windows •[...]

  • Page 2

    2 cFP-20xx Quick Start Guide ni.com Mounting the Backplane on a DIN Rail A. Fasten the DIN rail clip(s) to the cFP-BP- x using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the clip(s). B. Insert one edge of the DIN rail into the deeper opening of the DIN rail clip. C. Press down firmly on the backplane to[...]

  • Page 3

    Mounting the Backplane on a Panel A. Fasten the panel-mount plates to the back of the cFP-BP- x using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the kit. B. Bolt or screw the panel-mount accessory to a panel. C. Connect the PE ground terminal on the cFP-BP- x to safety ground. N A TIO N A L IN S TR U M [...]

  • Page 4

    Mounting the Backplane in a Standard 19-in. Rack A. Fasten the rack-mount bracket to the back of the cFP-BP- x using the captive screws on the bracket. B. Bolt the rack-mount accessory to a standard 19-in. rack. C. Connect the PE ground terminal on the cFP-BP- x to safety ground. C C A A U U T T I I O O N N Disconnect power before removing the back[...]

  • Page 5

    I I n n s s t t a a l l l l t t h h e e c c F F P P - - 2 2 0 0 x x x x C C o o n n t t r r o o l l l l e e r r o o n n t t h h e e B B a a c c k k p p l l a a n n e e A. Make sure that no power is connected to the controller or the backplane. B. Make sure that the cFP-20 xx controller is right side up with the NI logo at the top, and align the cap[...]

  • Page 6

    6 cFP-20xx Quick Start Guide ni.com I I n n s s t t a a l l l l I I / / O O M M o o d d u u l l e e s s o o n n t t h h e e B B a a c c k k p p l l a a n n e e A. Align the captive screws on the I/O module with the holes on the backplane. B. Press firmly to seat the I/O module on the backplane. C. Using a number 2 Phillips screwdriver with a shank [...]

  • Page 7

    I I n n s s t t a a l l l l C C o o n n n n e e c c t t o o r r B B l l o o c c k k s s o o n n t t h h e e B B a a c c k k p p l l a a n n e e In order to connect I/O modules to input signals or to external loads, you need to install a cFP-CB- x connector block or other connectivity accessory for each I/O module on the backplane. Use the connector[...]

  • Page 8

    C C o o n n n n e e c c t t t t h h e e c c F F P P - - 2 2 0 0 x x x x t t o o Y Y o o u u r r N N e e t t w w o o r r k k Connect the cFP-20 xx controller to an Ethernet network using the RJ-45 Ethernet port on the controller . Use a standard Category 5 Ethernet cable to connect the cFP-20 xx to an Ethernet hub, or use an Ethernet crossover cable[...]

  • Page 9

    C. Use a separate power supply for each module that needs external power . D. Refer to the operating instructions for the power requirements of each I/O module. If a module requires external power , connect a power supply to the V and C inputs on the connector block for that module. If you want to power field I/O devices from a connector block, sup[...]

  • Page 10

    I I n n s s t t a a l l l l S S o o f f t t w w a a r r e e o o n n t t h h e e H H o o s s t t P P C C A. Install the software packages you plan to use, such as LabVIEW , LabVIEW RT , Lookout, Measurement Studio, or LabWindows/CVI, before you install the FieldPoint software. The FieldPoint software installation installs the LabVIEW VIs and example[...]

  • Page 11

    11 cFP-20xx Quick Start Guide © National Instruments Corporation C. Click the + + sign next to I I A A S S e e r r v v e e r r w w i i t t h h O O P P C C in the left pane to expand the view . Right-click F F i i e e l l d d P P o o i i n n t t and select A A d d d d a a c c o o m m m m r r e e s s o o u u r r c c e e t t o o t t h h i i s s s s e[...]

  • Page 12

    G. Enter values on the Network Settings tab of the System Configuration dialog box, shown in the figure at right. If your network does not have a gateway server or DNS server , you should set those parameters to 0.0.0.0. • I I P P A A d d d d r r e e s s s s —The unique, computer-readable address of a device on your network. An IP address is ty[...]

  • Page 13

    I. Enter an IP address for the T ime Server on the Servers tab of the System Configuration dialog box, shown in the figure at right. The time server is a networked computer that runs the National Instruments T ime Service installed by FieldPoint Explorer . Enter the IP address of the PC you are using. When you finish configuring the controller , th[...]

  • Page 14

    14 cFP-20xx Quick Start Guide ni.com F F i i n n d d i i n n g g a a n n d d C C o o n n f f i i g g u u r r i i n n g g D D e e v v i i c c e e s s a a n n d d C C h h a a n n n n e e l l s s After you have configured the cFP-20 xx in FieldPoint Explorer , follow these steps to configure Compact FieldPoint devices and channels. A. In the Comm Reso[...]

  • Page 15

    C. T o configure the hardware settings of a particular I/O module, right-click the device name and select E E d d i i t t t t h h i i s s d d e e v v i i c c e e . The Device Configuration dialog box appears, as shown in the figure above. For output modules, you can choose settings for Watchdog Configuration. Refer to the user manual for informatio[...]

  • Page 16

    16 cFP-20xx Quick Start Guide ni.com D. Click C C h h a a n n n n e e l l C C o o n n f f i i g g u u r r a a t t i i o o n n to access the Channel Configuration dialog box, shown in the figure at right. Make your selections in this dialog box as follows: 1. Select the type of channel to show , then select the channel(s) that you want to change. T [...]

  • Page 17

    17 cFP-20xx Quick Start Guide © National Instruments Corporation[...]

  • Page 18

    18 cFP-20xx Quick Start Guide ni.com S S a a v v i i n n g g H H a a r r d d w w a a r r e e C C o o n n f f i i g g u u r r a a t t i i o o n n a a s s P P o o w w e e r r - - U U p p S S t t a a t t e e When you are satisfied with the hardware configuration of the FieldPoint system, you can save this configuration as the new power -up state for t[...]

  • Page 19

    ni.com Go to ni.com/support for the most current manuals, examples, and troubleshooting information. For telephone support in the United States, create your service request at ni.com/ask and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: United States 512 683 [...]