Napoleon Patioflame GPFN manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Patioflame GPFN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Patioflame GPFN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Napoleon Patioflame GPFN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Napoleon Patioflame GPFN should contain:
- informations concerning technical data of Napoleon Patioflame GPFN
- name of the manufacturer and a year of construction of the Napoleon Patioflame GPFN item
- rules of operation, control and maintenance of the Napoleon Patioflame GPFN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Patioflame GPFN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Patioflame GPFN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Patioflame GPFN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Patioflame GPFN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    W415-0638 / 04.24.08 1 W415-0638 / 04.24.08 $10.00[...]

  • Page 2

    W415-0638 / 04.24.08 2 WARNING T ABLE of CONTENTS PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE 7 FINISHING Log Placement 8 OPERA TION Operating Instructions Maintenance 9 MAINTENANCE High Elevation Installation 10-11 REPLACEMENTS Ordering Replacement Parts Replacement Parts PG 2-4 INTRODUCTION W arranty General Information 5 SPECIFICA TIONS Dimen[...]

  • Page 3

    W415-0638 / 04.24.08 3 NAP OLEON ® gas appliances are manu factured under the strict Standar d of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAP OLE ON® pr oducts are designed with superior components and materials, assembled by train ed cra ftsmen who take g reat prid e in the ir w ork .  e burner and valve assembl [...]

  • Page 4

    W415-0638 / 04.24.08 4 The installation must conform with Local codes or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/INFP A 54 in the United States or CSA B149.1, Natural and Propane Installation code in Canada. The appliance and its individual shut off valve must be disconnected from the gas supply piping system duri[...]

  • Page 5

    W415-0638 / 04.24.08 5 Inches mm Floor *0 *0 Side W alls 24 610 T op of unit to ceiling 72 1.830 Natural LP (Propane) Minimum Inlet Pressure 4.5" w .c. 1 1.0" w .c. Maximum Inlet Pressure 14.0"w .c 14.0"w .c. Model Fuel Max. Input Btu/Hr GPFN Natural Gas 60,000 GPFP Propane Gas 60,000 INPUT MINIMUM CLEARANCE T O COMB USTIBLES GA[...]

  • Page 6

    W415-0638 / 04.24.08 6 Natural Gas Supply Line (not supplied) Propane Regulator Hose Manual Gas V alve (on/off) QCC1 T ank Retaining Bracket INST ALLA TION The log set and the burner assembly are shipped together . Remove the gas log set and burner assembly and check for damage. DO NOT install damaged components. The logs are fragile use care when [...]

  • Page 7

    W415-0638 / 04.24.08 7 1. Set base log onto burner ensuring stud and bracket fi t into hole and notch. Base log should sit fl at on "Patiofl ame" base. FINISHING LOG PLA CEMENT / AGGREGA TE BASE LOG #1 #2 #3 #4 AGGREGA TE 6. Patiofl ame is supplied with 3lbs of lava rock. All 3lbs can be poured into outer ring. It may be mixed, or lay[...]

  • Page 8

    W415-0638 / 04.24.08 8 • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier , call the fi re depart- ment. Upon completing the ga[...]

  • Page 9

    W415-0638 / 04.24.08 9 1. The appliance should be inspected before initial use and inspected and cleaned at least annually by a quali fi ed fi eld service person. 2. T ampering is DANGEROUS and voids all warranties. Any component that is found to be faulty , must be replaced with an approved component. 3. T o obtain proper operation, it is impera[...]

  • Page 10

    W415-0638 / 04.24.08 10 1 W035-0104 OUTER BASE 1* W035-0173 OUTER BASE (LEG VERSION) 2 W655-0176 LOG SUPPORT 3 W010-1030 BURNER ASSEMBL Y 8 W080-0618 ORIFICE BRACKET 9 W455-0076 PROP ANE ORIFICE - #43 9 W455-0090 NA TURAL GAS ORIFICE - #23 9 W455-0079 #60 ori fi ce, "blank" (NG) 9 W455-0080 #60 ori fi ce, "blank" (LP) 10 GL-64[...]

  • Page 11

    W415-0638 / 04.24.08 11[...]

  • Page 12

    W415-0638 / 04.24.08 12 W olf Steel A ppliance Ser vice Histor y This appliance must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name[...]